 "manufacturer": "Autonics",
 "manufacturer_slug": "autonics",
 "model": "CT series programmable counter / timer (Modbus RTU)",
 "model_slug": "ct-series",
 "short_model": "Autonics CT",
 "aliases": [
  "CT4S",
  "CT6",
  "CT6S",
  "CT6M",
  "CT6Y",
  "CT6M-2P",
  "CT6S-1P4"
 ],
 "equipment_type": "Sensor / counter-timer (programmable counter and timer)",
 "applies_to": "Autonics CT series counters/timers with RS-485 communication, communication manual MCC-CTC1-V1.3-EN.",
 "summary": "Panel-mount programmable counter/timer with Modbus RTU. Coils and discrete inputs give outputs, reset and terminal inputs; input registers give model info, LED status, present value and preset values; holding registers set presets, counter and timer configuration and communication settings.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": null,
  "baud": null,
  "parity": null,
  "data_bits": null,
  "stop_bits": null,
  "tcp_port": null
 },
 "addressing": {
  "convention": "Modicon",
  "note": "Each row prints a 6-digit reference (000001/100001/300001/400001 style) followed by the hex protocol address in brackets, e.g. 301004 (03EB); the bracketed hex value is the wire address."
 },
 "default_word_order": "CDAB",
 "firmware": null,
 "source": {
  "title": "User Manual for Communication - Counters/Timers CT Series",
  "doc_number": "MCC-CTC1-V1.3-EN",
  "revision_date": null,
  "url": "https://cdn.automationdirect.com/static/manuals/autonics/autonicscommmanual.pdf",
  "unofficial": true,
  "pages": "pp. 11-19 (protocol), pp. 21-27 (mapping tables)"
 },
 "notes": [
  "Autonics does not offer a static public link to this manual (downloads go through its website); this is the unaltered Autonics document hosted by the distributor AutomationDirect.",
  "Word order: the manual states that for two-word data the upper data sits at the higher address, e.g. 301004 = present value low word and 301005 = high word (CDAB).",
  "Present and preset values are display counts; apply the decimal point from 400058 (counter) or the time range from 400102 (timer) yourself.",
  "Changing counter or timer group parameters over Modbus resets the current value; preset and communication changes keep it.",
  "Left out: prescale decimal point, prescale value and start value (400060-400064) and the time-range code table, whose printed layout is too garbled to transcribe reliably.",
  "Broadcast commands are not supported. Autonics recommends FC06 over FC16 for PLC/HMI writes."
 ],
 "registers": [
  {
   "table": "coil",
   "address": 0,
   "documented": "000001 (0000)",
   "name": "Reset",
   "description": "Write ON (FF00) with FC05 to reset.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 1,
   "documented": "000002 (0001)",
   "name": "OUT2 output",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 2,
   "documented": "000003 (0002)",
   "name": "OUT1 output",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 3,
   "documented": "000004 (0003)",
   "name": "BATCH output",
   "description": "BATCH-output models only.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 4,
   "documented": "000005 (0004)",
   "name": "BATCH reset",
   "description": "FC05 FF00 resets the batch counter (BATCH models).",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 0,
   "documented": "100001 (0000)",
   "name": "INA input status",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 1,
   "documented": "100002 (0001)",
   "name": "INB input status",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 2,
   "documented": "100003 (0002)",
   "name": "INHIBIT input status",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 3,
   "documented": "100004 (0003)",
   "name": "RESET input status",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 4,
   "documented": "100005 (0004)",
   "name": "BATCH RESET input status",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OFF",
    "1": "ON"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 100,
   "documented": "300101 (0064)",
   "name": "Product number H",
   "description": "Model ID, high word.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 101,
   "documented": "300102 (0065)",
   "name": "Product number L",
   "description": "Model ID, low word.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 102,
   "documented": "300103 (0066)",
   "name": "Hardware version",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 103,
   "documented": "300104 (0067)",
   "name": "Software version",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 104,
   "documented": "300105-300108 (0068-006B)",
   "name": "Model name",
   "description": "ASCII model text, e.g. 'CT6M-2PT'.",
   "data_type": "STRING",
   "length": 4,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1000,
   "documented": "301001 (03E8)",
   "name": "LED display status",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "5": "BA.O",
    "6": "OUT2",
    "7": "OUT1",
    "10": "BA.S",
    "11": "LOCK",
    "12": "PRESET2",
    "13": "PRESET1",
    "14": "TMR",
    "15": "CNT"
   },
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1001,
   "documented": "301002-301003 (03E9-03EA)",
   "name": "Present value of BATCH counter",
   "description": "0..999999. BATCH-output models.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1003,
   "documented": "301004-301005 (03EB-03EC)",
   "name": "Present value of counter/timer",
   "description": "Display count; decimal point per register 301006 / 400058.",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1005,
   "documented": "301006 (03ED)",
   "name": "Display unit",
   "description": "Counter: decimal point code (400058); timer: time range (400102).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1006,
   "documented": "301007-301008 (03EE-03EF)",
   "name": "PRESET2 (PRESET) setting value",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1008,
   "documented": "301009-301010 (03F0-03F1)",
   "name": "PRESET1 setting value",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1010,
   "documented": "301011-301012 (03F2-03F3)",
   "name": "Setting value of BATCH counter",
   "description": "0..999999.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1012,
   "documented": "301013 (03F4)",
   "name": "Checking the input logic",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "NPN",
    "1": "PNP"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 0,
   "documented": "400001-400002 (0000-0001)",
   "name": "PRESET2 (PRESET) setting value",
   "description": "Counter 0..999999 (4-digit 0..9999); timer within its range.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 2,
   "documented": "400003-400004 (0002-0003)",
   "name": "PRESET1 setting value",
   "description": "",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4,
   "documented": "400005-400006 (0004-0005)",
   "name": "BATCH counter setting value",
   "description": "0..999999.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 50,
   "documented": "400051 (0032)",
   "name": "Counter/Timer [C-T]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "COUN (counter)",
    "1": "TIME (timer)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 51,
   "documented": "400052 (0033)",
   "name": "Input mode [IN]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "UP",
    "1": "UP-1",
    "2": "UP-2",
    "3": "DN",
    "4": "DN-1",
    "5": "DN-2",
    "6": "UD-A",
    "7": "UD-B",
    "8": "UD-C"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 52,
   "documented": "400053 (0034)",
   "name": "Indication mode [DIsM]",
   "description": "Indicator models.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "TOTAL",
    "1": "HOLD"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 53,
   "documented": "400054 (0035)",
   "name": "Output mode [OUtM]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "F",
    "1": "N",
    "2": "C",
    "3": "R",
    "4": "K",
    "5": "P",
    "6": "Q",
    "7": "A",
    "8": "S",
    "9": "T",
    "10": "D"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 54,
   "documented": "400055 (0036)",
   "name": "Max. counting speed [CPS]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1 cps",
    "1": "30 cps",
    "2": "1K cps",
    "3": "5K cps",
    "4": "10K cps"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 55,
   "documented": "400056 (0037)",
   "name": "OUT2 (OUT) output time",
   "description": "Raw 1..99 in 10 ms steps.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 10,
   "units": "ms",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 56,
   "documented": "400057 (0038)",
   "name": "OUT1 output time",
   "description": "Raw 1..99 in 10 ms steps.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 10,
   "units": "ms",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57,
   "documented": "400058 (0039)",
   "name": "Decimal point [DP]",
   "description": "0 = none, 1..5 = 1..5 decimals (6-digit; 4-digit 0..3).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 58,
   "documented": "400059 (003A)",
   "name": "Min. reset time [RST]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1 ms",
    "1": "20 ms"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 64,
   "documented": "400065 (0040)",
   "name": "Memory protection [DATA] (counter)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "CLR",
    "1": "REC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 65,
   "documented": "400066 (0041)",
   "name": "Lock key [LOCK] (counter)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "LOFF",
    "1": "LOC1",
    "2": "LOC2",
    "3": "LOC3"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 100,
   "documented": "400101 (0064)",
   "name": "Count/Timer [C-T] (timer group)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "COUN",
    "1": "TIME"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 101,
   "documented": "400102 (0065)",
   "name": "Time range [HOUR/MIN/SEC]",
   "description": "Range code; tables differ for 4- and 6-digit models.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 102,
   "documented": "400103 (0066)",
   "name": "Up/Down mode [U-D]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "UP",
    "1": "DN"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 103,
   "documented": "400104 (0067)",
   "name": "Timer output mode [OUTM]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "OND",
    "1": "ONd1",
    "2": "ONd2",
    "3": "FLK",
    "4": "FLk1",
    "5": "FLk2",
    "6": "INT",
    "7": "INt1",
    "8": "INt2",
    "9": "OFD",
    "10": "NFD",
    "11": "NFd1",
    "12": "INTG"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 104,
   "documented": "400105 (0068)",
   "name": "Timer OUT2 (OUT) output time",
   "description": "Raw 1..99 x 10 ms; 0 = HOLD.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 10,
   "units": "ms",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 105,
   "documented": "400106 (0069)",
   "name": "Timer OUT1 output time",
   "description": "Raw 1..99 x 10 ms; 0 = HOLD.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 10,
   "units": "ms",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 106,
   "documented": "400107 (006A)",
   "name": "Input signal time [INT]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1 ms",
    "1": "20 ms"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 107,
   "documented": "400108 (006B)",
   "name": "Memory protection [DATA] (timer)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "CLR",
    "1": "REC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 108,
   "documented": "400109 (006C)",
   "name": "Lock key [LOCK] (timer)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "LOFF",
    "1": "LOC1",
    "2": "LOC2",
    "3": "LOC3"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 109,
   "documented": "400110 (006D)",
   "name": "Indication mode [DSpM] (timer)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "TOTAL",
    "1": "HOLD",
    "2": "ONtD"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 150,
   "documented": "400151 (0096)",
   "name": "Comm. address [ADDR]",
   "description": "1..127.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 151,
   "documented": "400152 (0097)",
   "name": "Comm. speed [BPS]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "2400 bps",
    "1": "4800 bps",
    "2": "9600 bps",
    "3": "19200 bps",
    "4": "38400 bps"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 152,
   "documented": "400153 (0098)",
   "name": "Comm. parity bit [PRTY]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "None",
    "1": "Even",
    "2": "Odd"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 153,
   "documented": "400154 (0099)",
   "name": "Comm. stop bit [STP]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1",
    "1": "2"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 154,
   "documented": "400155 (009A)",
   "name": "Response waiting time [RSwT]",
   "description": "5..99 ms.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "ms",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 155,
   "documented": "400156 (009B)",
   "name": "Comm. writing [COmW]",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Enabled",
    "1": "Disabled"
   },
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Read input registers 301001-301013 in one FC04 request for LED status, present value and presets; write presets at 400001-400006 and use coil 0 (FC05 FF00) to reset.",
  "minimum_registers": [
   {
    "table": "input_register",
    "address": 1003,
    "why": "Present value"
   },
   {
    "table": "input_register",
    "address": 1000,
    "why": "Output/LED status"
   },
   {
    "table": "holding_register",
    "address": 0,
    "why": "PRESET2 setpoint"
   },
   {
    "table": "holding_register",
    "address": 2,
    "why": "PRESET1 setpoint"
   },
   {
    "table": "coil",
    "address": 0,
    "why": "Reset"
   },
   {
    "table": "input_register",
    "address": 1005,
    "why": "Decimal point / time range"
   }
  ],
  "enable": "Set communication writing [COmW] (400156) to Enabled to allow Modbus writes; address, speed, parity and stop bits are in the communication group (also on the front panel).",
  "watchdog": null,
  "quirks": [
   "32-bit values are low word first.",
   "The bracketed hex number is the wire address; the 6-digit number is a reference only."
  ],
  "setup": [
   "Address 1..127, 2400-38400 bps, parity and stop bits set in the communication group.",
   "Response waiting time 5..99 ms (RSwT)."
  ],
  "gotchas": [
   "Writing counter/timer group settings resets the count."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/autonics/ct-series",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}