 "manufacturer": "BTicino",
 "manufacturer_slug": "bticino",
 "model": "PM multifunction meter F3N200 (Modbus RTU)",
 "model_slug": "f3n200",
 "short_model": "F3N200",
 "aliases": [
  "F3N200",
  "BTicino PM F3N200"
 ],
 "equipment_type": "Power meter",
 "applies_to": "BTicino PM multifunction meter catalogue number F3N200 with RS-485, per Modbus table IDP000024 v1.01.",
 "summary": "The F3N200 is a BTicino PM multifunction meter with an RS-485 Modbus RTU port. Its main readings are 32-bit scaled integers starting at 50512 (hex C550), but the document never states their word order, so this map lists the 16-bit copies at 51280 instead: voltages, currents, frequency, power, power factor, energy, temperature and THD, plus setup registers and the reset/save commands.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": null,
  "baud": null,
  "parity": null,
  "data_bits": 8,
  "stop_bits": null,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "The table prints three columns: a 'Register Number' (address + 1) and the 'Register Address' in decimal and hex. The register address is the wire address: the worked example reads V1 with request 05 03 C558 0002, so 50520 (C558) goes on the wire unchanged."
 },
 "default_word_order": null,
 "firmware": null,
 "source": {
  "title": "PM Multifunction meter Cat No. F3N200 - ModbusTable BT EN v1.01",
  "doc_number": "IDP000024 v1.01",
  "revision_date": null,
  "url": "https://dar.bticino.it/asset/Documents/IDP000024_EN_v1.01.pdf",
  "pages": "p. 1 (protocol details, encoding), pp. 4-7 (read-only words), p. 7 (example), pp. 8-10 (read/write words)"
 },
 "notes": [
  "The document states only the byte order ('Big Endian, most significant byte first') and never which word of a 2-register value comes first, so every 32-bit register is left out. The 16-bit copies of the live values (51280 block) are listed instead.",
  "The table groups these values under 'INPUT REGISTERS' but gives function code 3 for reading them, and the worked example uses function 03, so they are listed as holding registers.",
  "The worked example requests 2 registers for V1 but shows a 2-byte reply (08FC = 2300 x 0.01 = 230 V); it confirms the address and scale, not the word order.",
  "Unavailable values read 0xFFFFFFFF (unsigned) or 0x7FFFFFFF (signed); 16-bit copies use 0xFFFF / 0x7FFF.",
  "The 51280 block holds 16-bit values that the table says are not affected by the CT/VT ratios; the 50512 block includes them.",
  "Left out: the customisation and TC-correction block at 4096, whose data types are not given; alarm min/max values and alarm duration (no data type); alarm type, thresholds and hysteresis (36363-36367), because the alarm-type code list repeats codes 5-9 and thresholds have no units; and setup registers 36355/36356, whose rows run together so the 'Reserved' register and the current-averaging period can't be told apart; and the hour-meter trigger threshold (36362), whose unit is printed as A/V.",
  "The setup and network registers have no data type column; they are single-word values listed here as UINT16."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 1024,
   "documented": "1024",
   "name": "Reset",
   "description": "Write-only (function 06); codes can be added together.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": {
    "1": "Max currents",
    "2": "Max P+, Q+, S",
    "128": "kWh+",
    "256": "kvarh+",
    "4096": "All parameters"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36176,
   "documented": "36176",
   "name": "Alarm cause, lower threshold",
   "description": "Which measurement tripped the low-threshold alarm.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "I1",
    "2": "I2",
    "3": "I3",
    "4": "IN",
    "5": "U12",
    "6": "U23",
    "7": "U31",
    "8": "Total P+",
    "9": "Total Q+",
    "10": "Total S",
    "11": "F",
    "12": "Total PF lagging",
    "15": "THD I1",
    "16": "THD I2",
    "17": "THD I3",
    "18": "THD U12",
    "19": "THD U23",
    "20": "THD U31",
    "21": "Hour",
    "22": "V1",
    "23": "V2",
    "24": "V3",
    "26": "THD V1",
    "27": "THD V2",
    "28": "THD V3",
    "31": "Total PF leading",
    "32": "Temperature 1"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36178,
   "documented": "36178",
   "name": "Alarm cause, upper threshold",
   "description": "Which measurement tripped the high-threshold alarm.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "I1",
    "2": "I2",
    "3": "I3",
    "4": "IN",
    "5": "U12",
    "6": "U23",
    "7": "U31",
    "8": "Total P+",
    "9": "Total Q+",
    "10": "Total S",
    "11": "F",
    "12": "Total PF lagging",
    "15": "THD I1",
    "16": "THD I2",
    "17": "THD I3",
    "18": "THD U12",
    "19": "THD U23",
    "20": "THD U31",
    "21": "Hour",
    "22": "V1",
    "23": "V2",
    "24": "V3",
    "26": "THD V1",
    "27": "THD V2",
    "28": "THD V3",
    "31": "Total PF leading",
    "32": "Temperature 1"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36352,
   "documented": "36352",
   "name": "Network type (setup table)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1BL",
    "1": "2BL",
    "2": "3BL",
    "3": "3NBL",
    "4": "4BL",
    "5": "4NBL"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36353,
   "documented": "36353",
   "name": "CT secondary (setup table)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "RW",
   "values": {
    "1": "1 A",
    "5": "5 A"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36354,
   "documented": "36354",
   "name": "CT primary (setup table)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36357,
   "documented": "36357",
   "name": "P/Q/S average/max integration period",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "10": "10 s",
    "300": "5 min",
    "480": "8 min",
    "600": "10 min",
    "900": "15 min",
    "1200": "20 min",
    "1800": "30 min",
    "3600": "60 min"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36358,
   "documented": "36358",
   "name": "OUT1 allocation",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "kWh+ pulses",
    "1": "kvarh+ pulses",
    "2": "Alarm",
    "3": "Command"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36359,
   "documented": "36359",
   "name": "OUT1 pulse weight",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "0.1 kWh/kvarh",
    "1": "1 kWh/kvarh",
    "2": "10 kWh/kvarh",
    "3": "100 kWh/kvarh",
    "4": "1000 kWh/kvarh",
    "5": "10000 kWh/kvarh"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36360,
   "documented": "36360",
   "name": "OUT1 pulse duration",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "100 ms",
    "2": "200 ms",
    "3": "300 ms",
    "4": "400 ms",
    "5": "500 ms",
    "6": "600 ms",
    "7": "700 ms",
    "8": "800 ms",
    "9": "900 ms"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36361,
   "documented": "36361",
   "name": "Hour meter allocation",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Auxiliary supply",
    "2": "Currents",
    "3": "Phase-to-phase voltage"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36368,
   "documented": "36368",
   "name": "Relay state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Open",
    "1": "Closed"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 50848,
   "documented": "50848",
   "name": "Number of tariffs",
   "description": "0-8; 0 if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 50849,
   "documented": "50849",
   "name": "Tariff in progress",
   "description": "1-8; 0 if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51280,
   "documented": "51280",
   "name": "Hour meter (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51281,
   "documented": "51281",
   "name": "Voltage U12 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51282,
   "documented": "51282",
   "name": "Voltage U23 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51283,
   "documented": "51283",
   "name": "Voltage U31 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51284,
   "documented": "51284",
   "name": "Voltage V1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51285,
   "documented": "51285",
   "name": "Voltage V2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51286,
   "documented": "51286",
   "name": "Voltage V3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51287,
   "documented": "51287",
   "name": "Frequency (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Hz",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51288,
   "documented": "51288",
   "name": "Current I1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "mA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51289,
   "documented": "51289",
   "name": "Current I2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "mA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51290,
   "documented": "51290",
   "name": "Current I3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "mA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51291,
   "documented": "51291",
   "name": "Neutral current In (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "mA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51292,
   "documented": "51292",
   "name": "Total active power P (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51293,
   "documented": "51293",
   "name": "Total reactive power Q (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kvar",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51294,
   "documented": "51294",
   "name": "Total apparent power S (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kVA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51295,
   "documented": "51295",
   "name": "Total power factor (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.001,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51296,
   "documented": "51296",
   "name": "Active power P1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51297,
   "documented": "51297",
   "name": "Active power P2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51298,
   "documented": "51298",
   "name": "Active power P3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51299,
   "documented": "51299",
   "name": "Reactive power Q1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kvar",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51300,
   "documented": "51300",
   "name": "Reactive power Q2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kvar",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51301,
   "documented": "51301",
   "name": "Reactive power Q3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kvar",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51302,
   "documented": "51302",
   "name": "Apparent power S1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kVA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51303,
   "documented": "51303",
   "name": "Apparent power S2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kVA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51304,
   "documented": "51304",
   "name": "Apparent power S3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kVA",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51305,
   "documented": "51305",
   "name": "Power factor PF1 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.001,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51306,
   "documented": "51306",
   "name": "Power factor PF2 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.001,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51307,
   "documented": "51307",
   "name": "Power factor PF3 (16-bit)",
   "description": "Not affected by CT/VT ratios; 0x7FFF if not available.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.001,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51311,
   "documented": "51311",
   "name": "Total positive active energy Ea+ (not resettable)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "MWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51313,
   "documented": "51313",
   "name": "Total negative active energy Ea- (not resettable)",
   "description": "Not affected by CT/VT ratios; 0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "MWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51456,
   "documented": "51456",
   "name": "Internal temperature sensor present",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51457,
   "documented": "51457",
   "name": "Module temperature",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51536,
   "documented": "51536",
   "name": "THD U12",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51537,
   "documented": "51537",
   "name": "THD U23",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51538,
   "documented": "51538",
   "name": "THD U31",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51539,
   "documented": "51539",
   "name": "THD V1",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51540,
   "documented": "51540",
   "name": "THD V2",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51541,
   "documented": "51541",
   "name": "THD V3",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51542,
   "documented": "51542",
   "name": "THD I1",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51543,
   "documented": "51543",
   "name": "THD I2",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51544,
   "documented": "51544",
   "name": "THD I3",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51545,
   "documented": "51545",
   "name": "THD In",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 57344,
   "documented": "57344",
   "name": "Network type",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1BL",
    "1": "2BL",
    "2": "3BL",
    "3": "3NBL",
    "4": "4BL",
    "5": "4NBL"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 57345,
   "documented": "57345",
   "name": "CT secondary",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "RW",
   "values": {
    "1": "1 A",
    "5": "5 A"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 57346,
   "documented": "57346",
   "name": "CT primary",
   "description": "0xFFFF if not available.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 57856,
   "documented": "57856",
   "name": "Action",
   "description": "Write 0xA1 to save new settings, then 0xB2 to reboot.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": {
    "161": "0xA1: store configuration",
    "178": "0xB2: reboot"
   },
   "bits": null
  }
 ],
 "integration": {
  "summary": "Read holding registers with function 03 from 51280: the 16-bit block gives voltages, currents, frequency, power, power factor and energy without any word-order question. The 32-bit block at 50512 is more precise but its word order is not documented, so test it on a live meter before using it.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 51284,
    "why": "Phase 1 voltage"
   },
   {
    "table": "holding_register",
    "address": 51288,
    "why": "Phase 1 current"
   },
   {
    "table": "holding_register",
    "address": 51292,
    "why": "Total active power"
   },
   {
    "table": "holding_register",
    "address": 51295,
    "why": "Total power factor"
   },
   {
    "table": "holding_register",
    "address": 51287,
    "why": "Frequency"
   },
   {
    "table": "holding_register",
    "address": 51311,
    "why": "Imported active energy"
   }
  ],
  "enable": "Modbus address (1-247), baud rate, parity and stop bits are programmable; the table does not say where. To change setup over Modbus, write the registers, write 0xA1 to 57856 (E200) to store, then 0xB2 to reboot.",
  "watchdog": null,
  "quirks": [
   "Values are read with function 03 even though the table calls them input registers."
  ],
  "setup": [
   "RS-485 two-wire, RTU mode, 8 data bits; baud 2400-38400, parity none/odd/even and 1 or 2 stop bits are programmable.",
   "The table does not state factory defaults for address, baud or parity."
  ],
  "gotchas": [
   "Setup changes are not applied until 0xA1 (store) and 0xB2 (reboot) are written to 57856.",
   "Reset codes at 1024 can be OR-ed together; 0x1000 resets all parameters."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/bticino/f3n200",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}