 "manufacturer": "Danfoss",
 "manufacturer_slug": "danfoss",
 "model": "Gas Detection Units GD Basic / Premium / Heavy Duty (Modbus RTU)",
 "model_slug": "gas-detection-unit-gd",
 "short_model": "GD Basic/Premium",
 "aliases": [
  "GDA",
  "GDC",
  "GDHC",
  "GDHF",
  "GDH",
  "GD Basic",
  "GD Premium",
  "GD Heavy Duty"
 ],
 "equipment_type": "Sensor (refrigerant / toxic gas detector)",
 "applies_to": "Danfoss GD Basic, Premium and Heavy Duty gas detection units on their own RS-485 Modbus port (Part 2 of the guide). The gas detection controller's X-bus map in Part 1 is not included.",
 "summary": "Danfoss GD gas detection units (refrigerant, ammonia, CO2 and other gases) answer as Modbus RTU slaves on their RS-485 terminals. This map covers the per-sensor block (gas type, range, divisor, current and average value, error, alarm and relay bits, thresholds) and the operating-data block (production data, maintenance counters, extremes), plus the address-change register.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": null,
  "baud": 19200,
  "parity": "Even",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "The guide gives start addresses as they go in the request: the compact block is read from address 0 (impossible in 1-based numbering), the sensor block from 40 (shown as 28h) and operating data from 200. So register 43 is requested at address 43."
 },
 "default_word_order": null,
 "firmware": null,
 "source": {
  "title": "Danfoss Gas Detection - Modbus communication (User Guide)",
  "doc_number": "BC283429059843en-000301",
  "revision_date": "2020-09",
  "url": "https://assets.danfoss.com/documents/latest/149624/BC283429059843en-000301.pdf",
  "pages": "pp. 9-15 (Part 2: bus settings p. 9, compact block p. 9, sensor block pp. 10-11, operating data pp. 12-14, error codes p. 14, function 16 p. 15)"
 },
 "notes": [
  "Gas values are scaled per sensor: the divisor register (42/54/66) says what to divide the current value, average value and thresholds by (e.g. divisor 10 -> 1301 = 130.1). It depends on the measuring range, so it is read rather than fixed; scale is left at 1 here.",
  "The guide also offers a compact block: exactly 10 words read from address 0 (current and average value of sensors 1-3, then type + range words and a temperature word). It is left out because the guide does not say whether those words are signed or how the type, range and temperature words are encoded. Its gas values use a dynamic resolution: range under 10 -> value x 1000, 10-99 -> x 100, 100-999 -> x 10, 1000 and up -> x 1.",
  "On Heavy Duty units only sensor 1 is populated; the other sensor slots read 0. The sensor 2 operating-data block (218-235) is for Premium units; the guide also lists a third block (236-253), included here for completeness.",
  "The units of the gas reading follow the gas type code (ppm, %LEL, %Vol, °C, %rH, mbar...); the code table in the guide is printed in a layout that does not line codes up with gases reliably, so it is not transcribed.",
  "Error words are bit coded and can combine, e.g. 0x8001 sensor element error, 0x8002 ADC error, 0x8004 supply voltage, 0x8040 over-temperature, 0x8100 under-range, 0x8200 over-range, 0x0080 maintenance due.",
  "Units of the operating-data concentration and temperature extremes are not stated in the guide.",
  "Part 1 of the same guide (the Gas Detection Controller's X-bus map with blocks 1001-1096, 2001-2032 etc.) is a different device and is not in this file.",
  "Each sensor block can also be read as registers 40-51 from the next slave address up (unit address + 1 for sensor 2, + 2 for sensor 3); this map uses the single-address layout 40-75."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 40,
   "documented": "40",
   "name": "Gas type, sensor 1",
   "description": "Gas type code (code table in the guide).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 41,
   "documented": "41",
   "name": "Measuring range, sensor 1",
   "description": "Full-scale range as a plain integer.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 42,
   "documented": "42",
   "name": "Divisor, sensor 1",
   "description": "Divide values and thresholds of this sensor by this number.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 43,
   "documented": "43",
   "name": "Current value, sensor 1",
   "description": "Gas reading x divisor; divide by register 42.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 44,
   "documented": "44",
   "name": "Average value, sensor 1",
   "description": "Average reading x divisor; divide by register 42.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 45,
   "documented": "45",
   "name": "Error, sensor 1",
   "description": "Bit-coded error word; codes listed in the guide.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 46,
   "documented": "46",
   "name": "Alarm status, sensor 1",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "4": "Alarm 1",
    "5": "Alarm 2",
    "6": "Alarm 3",
    "7": "Alarm 4",
    "12": "Alarm 1 self-hold (latched)",
    "13": "Alarm 2 self-hold (latched)",
    "14": "Alarm 3 self-hold (latched)",
    "15": "Alarm 4 self-hold (latched)"
   }
  },
  {
   "table": "holding_register",
   "address": 47,
   "documented": "47",
   "name": "Relays and digital inputs (sensor 1 block)",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Relay 1",
    "1": "Relay 2",
    "2": "Relay 3",
    "3": "Relay 4",
    "4": "Relay 5",
    "8": "Digital input 1",
    "9": "Digital input 2"
   }
  },
  {
   "table": "holding_register",
   "address": 48,
   "documented": "48",
   "name": "Alarm threshold 1, sensor 1",
   "description": "Threshold x divisor; divide by register 42.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 49,
   "documented": "49",
   "name": "Alarm threshold 2, sensor 1",
   "description": "Threshold x divisor; divide by register 42.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 50,
   "documented": "50",
   "name": "Alarm threshold 3, sensor 1",
   "description": "Threshold x divisor; divide by register 42.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 51,
   "documented": "51",
   "name": "Alarm threshold 4, sensor 1",
   "description": "Threshold x divisor; divide by register 42.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 52,
   "documented": "52",
   "name": "Gas type, sensor 2",
   "description": "Gas type code (code table in the guide).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 53,
   "documented": "53",
   "name": "Measuring range, sensor 2",
   "description": "Full-scale range as a plain integer.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 54,
   "documented": "54",
   "name": "Divisor, sensor 2",
   "description": "Divide values and thresholds of this sensor by this number.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 55,
   "documented": "55",
   "name": "Current value, sensor 2",
   "description": "Gas reading x divisor; divide by register 54.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 56,
   "documented": "56",
   "name": "Average value, sensor 2",
   "description": "Average reading x divisor; divide by register 54.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 57,
   "documented": "57",
   "name": "Error, sensor 2",
   "description": "Bit-coded error word; codes listed in the guide.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 58,
   "documented": "58",
   "name": "Alarm status, sensor 2",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "4": "Alarm 1",
    "5": "Alarm 2",
    "6": "Alarm 3",
    "7": "Alarm 4",
    "12": "Alarm 1 self-hold (latched)",
    "13": "Alarm 2 self-hold (latched)",
    "14": "Alarm 3 self-hold (latched)",
    "15": "Alarm 4 self-hold (latched)"
   }
  },
  {
   "table": "holding_register",
   "address": 59,
   "documented": "59",
   "name": "Relays and digital inputs (sensor 2 block)",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Relay 1",
    "1": "Relay 2",
    "2": "Relay 3",
    "3": "Relay 4",
    "4": "Relay 5",
    "8": "Digital input 1",
    "9": "Digital input 2"
   }
  },
  {
   "table": "holding_register",
   "address": 60,
   "documented": "60",
   "name": "Alarm threshold 1, sensor 2",
   "description": "Threshold x divisor; divide by register 54.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 61,
   "documented": "61",
   "name": "Alarm threshold 2, sensor 2",
   "description": "Threshold x divisor; divide by register 54.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 62,
   "documented": "62",
   "name": "Alarm threshold 3, sensor 2",
   "description": "Threshold x divisor; divide by register 54.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 63,
   "documented": "63",
   "name": "Alarm threshold 4, sensor 2",
   "description": "Threshold x divisor; divide by register 54.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 64,
   "documented": "64",
   "name": "Gas type, sensor 3",
   "description": "Gas type code (code table in the guide).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 65,
   "documented": "65",
   "name": "Measuring range, sensor 3",
   "description": "Full-scale range as a plain integer.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 66,
   "documented": "66",
   "name": "Divisor, sensor 3",
   "description": "Divide values and thresholds of this sensor by this number.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 67,
   "documented": "67",
   "name": "Current value, sensor 3",
   "description": "Gas reading x divisor; divide by register 66.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 68,
   "documented": "68",
   "name": "Average value, sensor 3",
   "description": "Average reading x divisor; divide by register 66.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 69,
   "documented": "69",
   "name": "Error, sensor 3",
   "description": "Bit-coded error word; codes listed in the guide.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 70,
   "documented": "70",
   "name": "Alarm status, sensor 3",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "4": "Alarm 1",
    "5": "Alarm 2",
    "6": "Alarm 3",
    "7": "Alarm 4",
    "12": "Alarm 1 self-hold (latched)",
    "13": "Alarm 2 self-hold (latched)",
    "14": "Alarm 3 self-hold (latched)",
    "15": "Alarm 4 self-hold (latched)"
   }
  },
  {
   "table": "holding_register",
   "address": 71,
   "documented": "71",
   "name": "Relays and digital inputs (sensor 3 block)",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Relay 1",
    "1": "Relay 2",
    "2": "Relay 3",
    "3": "Relay 4",
    "4": "Relay 5",
    "8": "Digital input 1",
    "9": "Digital input 2"
   }
  },
  {
   "table": "holding_register",
   "address": 72,
   "documented": "72",
   "name": "Alarm threshold 1, sensor 3",
   "description": "Threshold x divisor; divide by register 66.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 73,
   "documented": "73",
   "name": "Alarm threshold 2, sensor 3",
   "description": "Threshold x divisor; divide by register 66.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 74,
   "documented": "74",
   "name": "Alarm threshold 3, sensor 3",
   "description": "Threshold x divisor; divide by register 66.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 75,
   "documented": "75",
   "name": "Alarm threshold 4, sensor 3",
   "description": "Threshold x divisor; divide by register 66.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 200,
   "documented": "200",
   "name": "Manufacturing day and month, sensor 1",
   "description": "Hex coded: high byte day, low byte month.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 201,
   "documented": "201",
   "name": "Manufacturing year, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 202,
   "documented": "202",
   "name": "Serial number, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 203,
   "documented": "203",
   "name": "Unit type, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "Sensor head",
    "2": "Basic / Premium unit",
    "3": "Gas detection controller"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 204,
   "documented": "204",
   "name": "Operating days, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 205,
   "documented": "205",
   "name": "Days until next maintenance, sensor 1",
   "description": "Negative = maintenance overdue.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 206,
   "documented": "206",
   "name": "Operating days at last calibration, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 207,
   "documented": "207",
   "name": "Maintenance interval, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 208,
   "documented": "208",
   "name": "Days left in previous maintenance period, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 209,
   "documented": "209",
   "name": "Sensor sensitivity, sensor 1",
   "description": "100 % = new sensor.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 210,
   "documented": "210",
   "name": "Calibrations performed, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 211,
   "documented": "211",
   "name": "Calibration tool serial number, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 212,
   "documented": "212",
   "name": "Calibration tool ID number, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 213,
   "documented": "213",
   "name": "Long-term average gas concentration, sensor 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 214,
   "documented": "214",
   "name": "Highest gas concentration measured, sensor 1",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 215,
   "documented": "215",
   "name": "Lowest temperature measured, sensor 1",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 216,
   "documented": "216",
   "name": "Highest temperature measured, sensor 1",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 218,
   "documented": "218",
   "name": "Manufacturing day and month, sensor 2",
   "description": "Hex coded: high byte day, low byte month.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 219,
   "documented": "219",
   "name": "Manufacturing year, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 220,
   "documented": "220",
   "name": "Serial number, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 221,
   "documented": "221",
   "name": "Unit type, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "Sensor head",
    "2": "Basic / Premium unit",
    "3": "Gas detection controller"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 222,
   "documented": "222",
   "name": "Operating days, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 223,
   "documented": "223",
   "name": "Days until next maintenance, sensor 2",
   "description": "Negative = maintenance overdue.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 224,
   "documented": "224",
   "name": "Operating days at last calibration, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 225,
   "documented": "225",
   "name": "Maintenance interval, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 226,
   "documented": "226",
   "name": "Days left in previous maintenance period, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 227,
   "documented": "227",
   "name": "Sensor sensitivity, sensor 2",
   "description": "100 % = new sensor.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 228,
   "documented": "228",
   "name": "Calibrations performed, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 229,
   "documented": "229",
   "name": "Calibration tool serial number, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 230,
   "documented": "230",
   "name": "Calibration tool ID number, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 231,
   "documented": "231",
   "name": "Long-term average gas concentration, sensor 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 232,
   "documented": "232",
   "name": "Highest gas concentration measured, sensor 2",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 233,
   "documented": "233",
   "name": "Lowest temperature measured, sensor 2",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 234,
   "documented": "234",
   "name": "Highest temperature measured, sensor 2",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 236,
   "documented": "236",
   "name": "Manufacturing day and month, sensor 3",
   "description": "Hex coded: high byte day, low byte month.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 237,
   "documented": "237",
   "name": "Manufacturing year, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 238,
   "documented": "238",
   "name": "Serial number, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 239,
   "documented": "239",
   "name": "Unit type, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "Sensor head",
    "2": "Basic / Premium unit",
    "3": "Gas detection controller"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 240,
   "documented": "240",
   "name": "Operating days, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 241,
   "documented": "241",
   "name": "Days until next maintenance, sensor 3",
   "description": "Negative = maintenance overdue.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 242,
   "documented": "242",
   "name": "Operating days at last calibration, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 243,
   "documented": "243",
   "name": "Maintenance interval, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 244,
   "documented": "244",
   "name": "Days left in previous maintenance period, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 245,
   "documented": "245",
   "name": "Sensor sensitivity, sensor 3",
   "description": "100 % = new sensor.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 246,
   "documented": "246",
   "name": "Calibrations performed, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 247,
   "documented": "247",
   "name": "Calibration tool serial number, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 248,
   "documented": "248",
   "name": "Calibration tool ID number, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 249,
   "documented": "249",
   "name": "Long-term average gas concentration, sensor 3",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 250,
   "documented": "250",
   "name": "Highest gas concentration measured, sensor 3",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 251,
   "documented": "251",
   "name": "Lowest temperature measured, sensor 3",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 252,
   "documented": "252",
   "name": "Highest temperature measured, sensor 3",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 333,
   "documented": "333",
   "name": "Device address (write to readdress)",
   "description": "Write the new slave address with function 16, length 1.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  }
 ],
 "integration": {
  "summary": "Read the sensor block at 40 (12 registers per sensor, up to 48 in one request) and divide the current value by the divisor register. Alarm and relay states are bit fields in the same block.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 40,
    "why": "Gas type of sensor 1"
   },
   {
    "table": "holding_register",
    "address": 42,
    "why": "Divisor needed to scale sensor 1 values"
   },
   {
    "table": "holding_register",
    "address": 43,
    "why": "Sensor 1 current gas value"
   },
   {
    "table": "holding_register",
    "address": 45,
    "why": "Sensor 1 error word"
   },
   {
    "table": "holding_register",
    "address": 46,
    "why": "Sensor 1 alarm 1-4 bits"
   },
   {
    "table": "holding_register",
    "address": 47,
    "why": "Relay and digital input states"
   }
  ],
  "enable": "The RS-485 Modbus port (Bus A / Bus B terminals) is always a slave at 19200 baud, 8 data bits, even parity, 1 stop bit. The slave address can be changed by writing the new address to register 333 with function 16.",
  "watchdog": null,
  "quirks": [
   "Only function 03 reads are supported; nothing can be written with function 06, and function 16 is accepted only for the address-change register 333.",
   "The compact block (not listed here) must be read as exactly 10 words starting at address 0."
  ],
  "setup": [
   "Poll each unit no faster than every 100 ms; with poll intervals under 550 ms, add at least one pause longer than 550 ms per polling cycle."
  ],
  "gotchas": [
   "Changing the address with register 333 readdresses every device sharing the old address, so only one device with that address may be on the bus."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/danfoss/gas-detection-unit-gd",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}