 "manufacturer": "eCharge Hardy Barth",
 "manufacturer_slug": "echarge-hardy-barth",
 "model": "eCharge EVCS (cPH2 / Salia controller), Modbus TCP map 2.3.0",
 "model_slug": "evcs-modbus-tcp-2-3",
 "short_model": "eCharge EVCS",
 "aliases": [
  "cPH2",
  "cPH22T22",
  "Hardy Barth Salia",
  "eCharge cPH2",
  "Hardy Barth wallbox"
 ],
 "equipment_type": "EV charger",
 "applies_to": "AC eCharge charging stations on firmware 2.5.2 or later, which report MapVersion 2.3.0; firmware 2.4.4-2.5.1 (MapVersion 2.0.0) has the same layout but different behaviour.",
 "summary": "eCharge Hardy Barth AC charging stations with the Salia controller run a Modbus TCP server on port 502 for EMS and SCADA control. Telemetry is in input registers, identity, configuration and control points in holding registers; floats and 32-bit values are big-endian with the high word first and need no scaling. Charging is controlled with a current target and a pause/allow register, with an optional heartbeat failsafe.",
 "transport": [
  "TCP"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": null,
  "parity": null,
  "data_bits": null,
  "stop_bits": null,
  "tcp_port": 502
 },
 "addressing": {
  "convention": "Modicon",
  "note": "Each row gives the 3xxxx/4xxxx number and the zero-based PDU address; PDU = register - 30001 (input) or - 40001 (holding). The manual's example frame 06 00 C9 00 10 writes 16 A to 40202 at PDU 201."
 },
 "default_word_order": "ABCD",
 "firmware": "2.5.2 (MapVersion 2.3.0)",
 "source": {
  "title": "Modbus TCP Documentation",
  "doc_number": "Document version 2.3.0 (MapVersion 2.3.0)",
  "revision_date": "2026-11-05",
  "url": "https://docs.echarge.de/modbus-tcp/documentation.md",
  "pages": "Sections: Data representation and endianness; Addressing conventions; Register map overview; Enumerations; Controlling the charger; Entering (and leaving) failsafe"
 },
 "notes": [
  "Official documentation from eCharge's own docs site (markdown page).",
  "Word order: the manual states big-endian word order (high word at the lower address) and big-endian bytes for all multi-register values; values are already in engineering units (scale 1).",
  "Left out: Mains/Battery block 30501-30527 (the manual says this firmware does not populate it), StatusWord 30003 (reserved, always 0), ChargingInfo 30005 (free text, not for parsing), PhaseSwitchDelay/Duration 30305/30306 (the manual says they are unreliable), meter identity strings 41001-41024, and the accepted-but-ignored control registers 40201, 40205, 40207 and 40210-40225.",
  "Unused addresses read 0 without an exception, so a wrong function code or an off-by-one address returns zeros; read MapVersion (40001) first to check addressing.",
  "Other Unit IDs on the same IP: 2-4 forward to linked slave stations, and 100 (if enabled) is a Fronius-style SunSpec meter emulation starting with 'SunS' at 40001."
 ],
 "registers": [
  {
   "table": "input_register",
   "address": 0,
   "documented": "30001",
   "name": "EVCS_State",
   "description": "Station state derived every 2 s.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "NOT_READY",
    "1": "READY",
    "2": "CHARGING",
    "3": "CHARGING_INTERRUPTED",
    "4": "ERROR",
    "5": "AUTH_REJECTED (reserved)",
    "6": "RESERVED",
    "7": "PHASE_SWITCHING"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1,
   "documented": "30002",
   "name": "Connector_State",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "UNPLUGGED (not reported)",
    "1": "PLUGGED_ON_STATION_ONLY",
    "2": "PLUGGED_ON_STATION_AND_VEHICLE",
    "3": "ERROR_UNAVAILABLE"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 3,
   "documented": "30004",
   "name": "ErrorCode",
   "description": "Highest-priority active condition.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No error",
    "1": "Internal hardware fault",
    "2": "Over-current or short circuit",
    "3": "Over- or under-voltage",
    "4": "Over-temperature (electronics)",
    "5": "Energy meter communication failure",
    "6": "Lock/plug fault",
    "7": "Failsafe active"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 20,
   "documented": "30021",
   "name": "AuthorizationStatus",
   "description": "1 when the station has authorised the session.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 21,
   "documented": "30022",
   "name": "AuthType",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "FREE",
    "1": "RFID",
    "2": "KEYSWITCH",
    "3": "OCPP"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 22,
   "documented": "30023",
   "name": "Uptime",
   "description": "Seconds since boot.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 24,
   "documented": "30025",
   "name": "Temperature",
   "description": "Electronics temperature, whole degrees (not a float).",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 26,
   "documented": "30027",
   "name": "Failsafe_Active",
   "description": "1 while the communication-loss failsafe is active.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 49,
   "documented": "30050",
   "name": "DaemonStatus",
   "description": "Gateway health flags.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "units_ready - gateway ready",
    "1": "mqtt_connected - link to charger up",
    "2": "api_seed_succeeded",
    "3": "persistence_degraded - failsafe setting not yet saved",
    "4": "degraded_mode"
   },
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 100,
   "documented": "30101",
   "name": "Availability",
   "description": "1 when the station reports operative.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 101,
   "documented": "30102",
   "name": "GridCurrentLimit",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 102,
   "documented": "30103",
   "name": "PhaseCount",
   "description": "1 or 3.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 103,
   "documented": "30104",
   "name": "PhysicalCurrentLimit",
   "description": "Hardware limit.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 104,
   "documented": "30105",
   "name": "OfferedCurrentLimit",
   "description": "Limit advertised to the vehicle.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 105,
   "documented": "30106",
   "name": "CurrentOfferedTotal",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 107,
   "documented": "30108",
   "name": "CurrentOfferedL1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 109,
   "documented": "30110",
   "name": "CurrentOfferedL2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 111,
   "documented": "30112",
   "name": "CurrentOfferedL3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 113,
   "documented": "30114",
   "name": "PowerOffered",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 200,
   "documented": "30201",
   "name": "EV_Present",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 201,
   "documented": "30202",
   "name": "Charging",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 202,
   "documented": "30203",
   "name": "CP_Status",
   "description": "IEC 61851 control pilot state.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "A - standby, no vehicle",
    "1": "B - connected, not requesting",
    "2": "C - charging requested",
    "3": "D - ventilation required",
    "4": "E - error",
    "5": "F - EVSE fault"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 203,
   "documented": "30204",
   "name": "CP_PWM_State",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 204,
   "documented": "30205",
   "name": "CP_Duty_Cycle",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 219,
   "documented": "30220",
   "name": "Plug_Lock_Status",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Unlocked",
    "1": "Locked",
    "2": "Unknown"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 220,
   "documented": "30221",
   "name": "Plug_State_Actual",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Unlock",
    "1": "Lock"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 221,
   "documented": "30222",
   "name": "Plug_State_Target",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Unlock",
    "1": "Lock"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 222,
   "documented": "30223",
   "name": "Plug_Error",
   "description": "Firmware-specific plug-lock fault; 0 = none.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 223,
   "documented": "30224",
   "name": "Contactor_Status",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Opened",
    "1": "Closed",
    "2": "Unknown"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 224,
   "documented": "30225",
   "name": "Contactor_State_Actual",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Open",
    "1": "Close"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 225,
   "documented": "30226",
   "name": "Contactor_State_Target",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Open",
    "1": "Close"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 226,
   "documented": "30227",
   "name": "Contactor_Error",
   "description": "Firmware-specific contactor fault; 0 = none.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 227,
   "documented": "30228",
   "name": "PWM_Status",
   "description": "Mirror of CP_Duty_Cycle.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 300,
   "documented": "30301",
   "name": "PhaseSwitchingEnabled",
   "description": "As read from the configuration at service start.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 301,
   "documented": "30302",
   "name": "PhaseSwitchingStatus",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "IDLE",
    "1": "IN_PROGRESS"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 302,
   "documented": "30303",
   "name": "ActualPhase",
   "description": "0, 1 or 3 phases on the contactor; 0 when idle.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 303,
   "documented": "30304",
   "name": "TargetPhase",
   "description": "0, 1 or 3; last commanded phase count.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 400,
   "documented": "30401",
   "name": "RFID_Available",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 417,
   "documented": "30418",
   "name": "RFID_LastTag",
   "description": "Last RFID tag seen, upper case.",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 600,
   "documented": "30601",
   "name": "ChargeMode_Actual",
   "description": "Mode the station is actually running.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "ECO (PV surplus)",
    "1": "POWER (maximum)",
    "2": "MANUAL (EMS/user current)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 601,
   "documented": "30602",
   "name": "EcoPlus_Actual",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 602,
   "documented": "30603",
   "name": "PauseCharging_Actual",
   "description": "1 while the station itself or a user has paused charging.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 603,
   "documented": "30604",
   "name": "MaxCurrent_Actual",
   "description": "Live maximum, e.g. the load-management share.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1000,
   "documented": "31001",
   "name": "MeterFrequency",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Hz",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1002,
   "documented": "31003",
   "name": "Voltage_L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1004,
   "documented": "31005",
   "name": "Voltage_L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1006,
   "documented": "31007",
   "name": "Voltage_L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1008,
   "documented": "31009",
   "name": "Current_L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1010,
   "documented": "31011",
   "name": "Current_L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1012,
   "documented": "31013",
   "name": "Current_L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1014,
   "documented": "31015",
   "name": "Power_Total",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1016,
   "documented": "31017",
   "name": "Power_L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1018,
   "documented": "31019",
   "name": "Power_L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1020,
   "documented": "31021",
   "name": "Power_L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 1022,
   "documented": "31023",
   "name": "Energy_Total",
   "description": "Lifetime meter total, not the session energy.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 0,
   "documented": "40001",
   "name": "MapVersion",
   "description": "Register-map version, e.g. 2.3.0.",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 8,
   "documented": "40009",
   "name": "Model",
   "description": "Model designation, e.g. cPH22T22.",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24,
   "documented": "40025",
   "name": "SerialNumber",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32,
   "documented": "40033",
   "name": "Manufacturer",
   "description": "",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 48,
   "documented": "40049",
   "name": "FirmwareVersionStr",
   "description": "Firmware version text, e.g. 2.3.75.",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 56,
   "documented": "40057",
   "name": "FirmwareVersionU32",
   "description": "Packed version: one byte major, one byte minor, one word patch.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 64,
   "documented": "40065",
   "name": "ModelType",
   "description": "Fixed text EV_CHARGING_STATION.",
   "data_type": "STRING",
   "length": 12,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 100,
   "documented": "40101",
   "name": "FuseRating",
   "description": "Configured mains (house) fuse rating.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 101,
   "documented": "40102",
   "name": "EcoPlusTimeout",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 102,
   "documented": "40103",
   "name": "EcoReference",
   "description": "Grid power reference for ECO mode; may be negative.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 103,
   "documented": "40104",
   "name": "MinCurrent",
   "description": "Configured minimum charge current 6-32 A; saved on write.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 104,
   "documented": "40105",
   "name": "MaxCurrent",
   "description": "Configured maximum 6-32 A, not above FuseRating; saved on write.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 105,
   "documented": "40106",
   "name": "EcoPlus",
   "description": "EMS setpoint; actual value at IR 30602.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 106,
   "documented": "40107",
   "name": "ChargeMode",
   "description": "EMS setpoint; actual value at IR 30601.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "ECO (PV surplus)",
    "1": "POWER (maximum)",
    "2": "MANUAL (EMS/user current)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 201,
   "documented": "40202",
   "name": "Set_Charge_Current_Target",
   "description": "0 stops; otherwise within MinCurrent-MaxCurrent.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 202,
   "documented": "40203",
   "name": "Start_Stop_Charging",
   "description": "Pauses or allows energy; never authorises a session.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Pause energy",
    "1": "Allow energy"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 203,
   "documented": "40204",
   "name": "Failsafe_Timeout",
   "description": "0 = off, or 10-3600 s.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 205,
   "documented": "40206",
   "name": "Failsafe_Current_Target",
   "description": "Current applied when the failsafe trips; 0 or within the window.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 207,
   "documented": "40208",
   "name": "Heartbeat",
   "description": "Write any value to keep the failsafe timer reset.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 208,
   "documented": "40209",
   "name": "Target_Phase",
   "description": "1 or 3; needs phase switching enabled; acts only during a session.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1024,
   "documented": "41025",
   "name": "MeterPhaseCount",
   "description": "1 or 3.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1025,
   "documented": "41026",
   "name": "MeterAvailable",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Connect to port 502 at Unit ID 1. Set ChargeMode (40107) to MANUAL, then write the current target and Start_Stop_Charging together in one FC16 frame (40202-40203); poll EVCS_State, ErrorCode and the meter block from 30001/31001.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 201,
    "why": "Charge current target"
   },
   {
    "table": "holding_register",
    "address": 202,
    "why": "Pause / allow energy"
   },
   {
    "table": "input_register",
    "address": 0,
    "why": "Station state"
   },
   {
    "table": "input_register",
    "address": 3,
    "why": "Error code"
   },
   {
    "table": "input_register",
    "address": 1014,
    "why": "Charging power"
   },
   {
    "table": "input_register",
    "address": 1022,
    "why": "Meter energy total"
   },
   {
    "table": "holding_register",
    "address": 207,
    "why": "Heartbeat for the failsafe"
   },
   {
    "table": "holding_register",
    "address": 104,
    "why": "Configured maximum current"
   }
  ],
  "enable": "The Modbus TCP server listens on port 502 by default. An installer may set an IP allow-list in the station's web configuration; ask for your EMS address to be added.",
  "watchdog": "Failsafe_Timeout (40204, 0 = off or 10-3600 s). If no accepted write to 40202, 40203, 40208 or 40209 arrives within the timeout, the station applies Failsafe_Current_Target (40206), sets Failsafe_Active (30027) and ErrorCode 7. Write Heartbeat (40208) at least every timeout/2.",
  "quirks": [
   "Start (40203 = 1) is rejected with exception 03 while the current target is 0; write both in one FC16 frame.",
   "While 40203 = 0 the charger is offered 0 A whatever 40202 says.",
   "Temperature (30025) is a u32 integer, not a float.",
   "A change of charge mode resets the station's limit to its maximum and overrides the Modbus current target.",
   "Unit IDs 0 and 255 are refused with exception 0B."
  ],
  "setup": [
   "Static IP or DHCP (default) on the station's Ethernet port; Modbus TCP port 502, Unit ID 1.",
   "Up to 32 connections total and 4 per source IP; 50 requests/s per IP (burst 100).",
   "Idle connections close after 5 minutes."
  ],
  "gotchas": [
   "Before an EMS stops controlling the station, write a current with 40203 = 1 and set 40204 = 0, or the station can stay limited to 0 A.",
   "Read-only integrations should keep the failsafe off (40204 = 0); stations updated from MapVersion 2.0.0 often keep a saved 20 s / 0 A failsafe.",
   "A phase switch (40209) only runs during an active session; confirm it at ActualPhase (30303)."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/echarge-hardy-barth/evcs-modbus-tcp-2-3",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}