 "manufacturer": "Fronius",
 "manufacturer_slug": "fronius",
 "model": "Fronius Sensor Card via Datamanager (SunSpec 302/303/307)",
 "model_slug": "sensor-card-datamanager-sunspec",
 "short_model": "Fronius Sensor Card",
 "aliases": [
  "Fronius Sensor Card",
  "IG Sensor Card"
 ],
 "equipment_type": "Sensor",
 "applies_to": "A Fronius Sensor Card connected to a Fronius Datamanager over Solar Net and republished by it as a SunSpec device; the same layout is used for the float and int+SF settings.",
 "summary": "The Datamanager publishes each Fronius Sensor Card as its own Modbus device (unit ID 245 for Solar Net address 0, up to 247). After the common block it carries SunSpec irradiance model 302, back-of-module temperature model 303 and base meteorological model 307. This map covers the identification block, irradiance, both temperature inputs and wind speed.",
 "transport": [
  "TCP",
  "RTU"
 ],
 "defaults": {
  "unit_id": 245,
  "baud": null,
  "parity": null,
  "data_bits": null,
  "stop_bits": null,
  "tcp_port": 502
 },
 "addressing": {
  "convention": "1-based",
  "note": "Fronius numbers registers from 1 (SunSpec base register 40001) and tells you to request the register number minus one, so register 40072 is read at wire address 40071. The manual's RTU example reads register 40005 with address bytes 9C 44 (40004)."
 },
 "default_word_order": null,
 "firmware": "Register map archive version 1.1.7-0 (IG_Sensor_Card_Register_Map_Float_and_Int&SF_v1.0.xlsx); manual 42,0410,2049 rev. 033-24022026.",
 "source": {
  "title": "Fronius Datamanager Modbus TCP & RTU (operating instructions) + IG_Sensor_Card_Register_Map_Float_and_Int&SF_v1.0.xlsx",
  "doc_number": "42,0410,2049 (033-24022026)",
  "revision_date": "2026-02",
  "url": "https://www.fronius.com/en/~/downloads/Solar%20Energy/Operating%20Instructions/42,0410,2049.pdf",
  "pages": "PDF English part: printed p. 66 (Modbus device ID for Fronius Sensor Cards: offset 245); register table = XLSX 'Complete Map' sheet in https://www.fronius.com/en/~/downloads/Solar%20Energy/Operating%20Instructions/SE_EI_Modbus_Sunspec_Maps_State_Codes_Events_EN.zip"
 },
 "notes": [
  "Register table from Fronius' official XLSX in the Modbus SunSpec maps ZIP; the unit-ID rule comes from the PDF.",
  "The XLSX gives a fixed scale factor of -1 for the temperatures (raw x 0.1); GHI and wind speed have no scale factor and are used as read.",
  "Left out: the 32-bit SID (40001-40002, word order not stated) and every point the XLSX marks not supported (POAI, DFI, DNI, OTI, the second TmpBOM at 40080, RH, pressure, wind direction, rain, snow, precipitation type, electric field, surface and soil wetness).",
  "Changelog 1.1.5-0 notes that TmpAmb (40083) is mapped to temperature sensor 2 and the second TmpBOM register is not supported."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 40002,
   "documented": "40003",
   "name": "Common ID",
   "description": "Common block ID, reads 1.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40003,
   "documented": "40004",
   "name": "Common L",
   "description": "Common block length, reads 65.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40004,
   "documented": "40005",
   "name": "Mn",
   "description": "Manufacturer name (Fronius).",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40020,
   "documented": "40021",
   "name": "Md",
   "description": "Device model name.",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40036,
   "documented": "40037",
   "name": "Opt",
   "description": "Options string.",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40044,
   "documented": "40045",
   "name": "Vr",
   "description": "Software version.",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40052,
   "documented": "40053",
   "name": "SN",
   "description": "Serial number.",
   "data_type": "STRING",
   "length": 16,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40068,
   "documented": "40069",
   "name": "DA",
   "description": "Modbus device address.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40069,
   "documented": "40070",
   "name": "Irradiance ID",
   "description": "SunSpec irradiance model, reads 302.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40070,
   "documented": "40071",
   "name": "Irradiance L",
   "description": "Model length, reads 5.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40071,
   "documented": "40072",
   "name": "GHI",
   "description": "Global horizontal irradiance.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "W/m2",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40076,
   "documented": "40077",
   "name": "BOM temperature ID",
   "description": "SunSpec back-of-module temperature model, reads 303.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40077,
   "documented": "40078",
   "name": "BOM temperature L",
   "description": "Model length, reads 2.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40078,
   "documented": "40079",
   "name": "TmpBOM",
   "description": "Back-of-module temperature from temperature sensor 1.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40080,
   "documented": "40081",
   "name": "Meteorological ID",
   "description": "SunSpec base meteorological model, reads 307.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40081,
   "documented": "40082",
   "name": "Meteorological L",
   "description": "Model length, reads 11.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40082,
   "documented": "40083",
   "name": "TmpAmb",
   "description": "Ambient temperature from temperature sensor 2.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40085,
   "documented": "40086",
   "name": "WndSpd",
   "description": "Wind speed.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40093,
   "documented": "40094",
   "name": "End ID",
   "description": "End block marker, reads 0xFFFF.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40094,
   "documented": "40095",
   "name": "End L",
   "description": "End block length, reads 0.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Enable Modbus on the Datamanager and poll the sensor card at unit ID 245 + its Solar Net address. Read 40072 for irradiance and 40079-40086 for temperatures and wind speed.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 40069,
    "why": "Model ID 302 confirms the layout"
   },
   {
    "table": "holding_register",
    "address": 40071,
    "why": "Global horizontal irradiance"
   },
   {
    "table": "holding_register",
    "address": 40078,
    "why": "Module temperature (sensor 1)"
   },
   {
    "table": "holding_register",
    "address": 40082,
    "why": "Ambient temperature (sensor 2)"
   },
   {
    "table": "holding_register",
    "address": 40085,
    "why": "Wind speed"
   }
  ],
  "enable": "In the Datamanager web interface open Settings > Modbus and set data output to tcp (or rtu). The sensor card must be connected to the Datamanager via Solar Net.",
  "watchdog": null,
  "quirks": [
   "The sensor card is a separate Modbus device: unit ID = 245 + Solar Net address (0-2 -> 245-247).",
   "Unlike the inverter and meter models, the sensor card layout does not change between float and int+SF."
  ],
  "setup": [
   "Sensor card Solar Net address 0 -> unit ID 245, 1 -> 246, 2 -> 247."
  ],
  "gotchas": [
   "Points marked not supported (humidity, pressure, wind direction and others) still exist in the block; ignore them."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/fronius/sensor-card-datamanager-sunspec",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}