 "manufacturer": "go-e",
 "manufacturer_slug": "go-e",
 "model": "go-eCharger (Modbus TCP API v1)",
 "model_slug": "go-echarger-api-v1",
 "short_model": "go-eCharger API v1",
 "aliases": [
  "go-eCharger Modbus API v1",
  "go-e Charger"
 ],
 "equipment_type": "EV charger",
 "applies_to": "go-eCharger wallboxes running firmware 0.40 or newer with the v1 API (Modbus TCP API v1 document version 1.0, 2020-10-01).",
 "summary": "The go-eCharger wallbox exposes a Modbus TCP server over WLAN once API access is enabled in the app. This map covers the single-register status and control points: charging state, errors, charge permission, access mode, cable lock, current setpoints and the push-button current levels.",
 "transport": [
  "TCP"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": null,
  "parity": null,
  "data_bits": null,
  "stop_bits": null,
  "tcp_port": 502
 },
 "addressing": {
  "convention": "0-based",
  "note": "The document says register IDs are 0-indexed and some clients must add 1. The table numbers are wire addresses: AMPERE_VOLATILE 299 is request address 299 (holding register 40300 in 1-based tools)."
 },
 "default_word_order": null,
 "firmware": null,
 "source": {
  "title": "GO-E Charger Modbus TCP/IP Documentation English",
  "doc_number": "go-eCharger Modbus TCP API v1 EN, version 1.0",
  "revision_date": "2020-10-01",
  "url": "https://raw.githubusercontent.com/goecharger/go-eCharger-API-v1/master/go-eCharger%20Modbus%20TCP%20API%20v1%20EN.md",
  "pages": "Modbus register table (single markdown page)"
 },
 "notes": [
  "The v1 document does not name which charger hardware generations it covers; check the API version against your charger's firmware.",
  "Official go-e documentation hosted in the goecharger GitHub organisation.",
  "Left out: all 32-bit values (voltages, currents, power, energy, power factor). The document only says the 16-bit registers are big-endian and does not state which register of a pair holds the high word, so the word order is not established.",
  "Left out: firmware version, MAC, serial number, host name and network addresses (ASCII/binary blocks).",
  "The source spells register 213 'AMLERE_L2'; it is listed here as AMPERE_L2."
 ],
 "registers": [
  {
   "table": "input_register",
   "address": 100,
   "documented": "100",
   "name": "CAR_STATE",
   "description": "Charging state as seen on the PWM pilot.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Unknown / charging station defective",
    "1": "Ready, no car",
    "2": "Car is charging",
    "3": "Waiting for car",
    "4": "Charging finished, car still connected"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 101,
   "documented": "101",
   "name": "PP_CABLE",
   "description": "Type 2 cable current coding: 13-32 A, 0 = no cable.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 107,
   "documented": "107",
   "name": "ERROR",
   "description": "Error code.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "1": "RCCB (residual current breaker)",
    "3": "Phase disturbance",
    "8": "No ground detected",
    "10": "Internal (others, default)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 202,
   "documented": "202",
   "name": "ADAPTER_INPUT",
   "description": "Adapter fitted to the charger.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No adapter",
    "1": "16 A adapter"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 203,
   "documented": "203",
   "name": "UNLOCKED_BY",
   "description": "Number of the RFID card that started this charge.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 205,
   "documented": "205",
   "name": "PHASES",
   "description": "Phase presence before/after the contactor.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Phase 1 after contactor",
    "1": "Phase 2 after contactor",
    "2": "Phase 3 after contactor",
    "3": "Phase 1 before contactor",
    "4": "Phase 2 before contactor",
    "5": "Phase 3 before contactor"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 200,
   "documented": "200",
   "name": "ALLOW",
   "description": "Whether the PWM charging signal is allowed.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 201,
   "documented": "201",
   "name": "ACCESS_STATE",
   "description": "Access control mode.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Open",
    "1": "RFID / app needed",
    "2": "Electricity price / automatic",
    "3": "Scheduler"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 204,
   "documented": "204",
   "name": "CABLE_LOCK_MODE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Lock while car is connected",
    "1": "Unlock automatically after charging",
    "2": "Always locked"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 206,
   "documented": "206",
   "name": "LED_BRIGHTNESS",
   "description": "0 = off, 255 = maximum.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 207,
   "documented": "207",
   "name": "LED_SAVE_ENERGY",
   "description": "LEDs switch off automatically after 10 s when on.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 208,
   "documented": "208",
   "name": "ELECTRICITY_PRICES_HOURS",
   "description": "Minimum hours to charge in electricity-price mode.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "h",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 209,
   "documented": "209",
   "name": "ELECTRICITY_PRICES_FINISHED",
   "description": "Hour of day by which price-mode charging must be done.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 210,
   "documented": "210",
   "name": "ELECTRICITY_PRICES_ZONE",
   "description": "aWATTar price zone.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Austria",
    "1": "Germany"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 211,
   "documented": "211",
   "name": "AMPERE_MAX",
   "description": "Upper limit for the current setting.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 212,
   "documented": "212",
   "name": "AMPERE_L1",
   "description": "Push-button current level 1: 6-32 A, 0 = skipped.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 213,
   "documented": "213",
   "name": "AMPERE_L2",
   "description": "Push-button current level 2: 6-32 A, 0 = skipped.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 214,
   "documented": "214",
   "name": "AMPERE_L3",
   "description": "Push-button current level 3: 6-32 A, 0 = skipped.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 215,
   "documented": "215",
   "name": "AMPERE_L4",
   "description": "Push-button current level 4: 6-32 A, 0 = skipped.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 216,
   "documented": "216",
   "name": "AMPERE_L5",
   "description": "Push-button current level 5: 6-32 A, 0 = skipped.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 217,
   "documented": "217",
   "name": "CLOUD_DISABLED",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Cloud enabled",
    "1": "Cloud disabled"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 218,
   "documented": "218",
   "name": "NORWAY_MODE",
   "description": "Disables ground detection; for IT networks only.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off (ground detection on)",
    "1": "On (no ground detection)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 299,
   "documented": "299",
   "name": "AMPERE_VOLATILE",
   "description": "Charge current 6-32 A, not saved; use for energy management.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 300,
   "documented": "300",
   "name": "AMPERE_EEPROM",
   "description": "Charge current 6-32 A, saved to EEPROM (about 100,000 writes).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Connect to port 502, unit 1. Read CAR_STATE (100) and ERROR (107), allow charging with ALLOW (200) and set the current with AMPERE_VOLATILE (299) for dynamic load management.",
  "minimum_registers": [
   {
    "table": "input_register",
    "address": 100,
    "why": "Charging state"
   },
   {
    "table": "input_register",
    "address": 107,
    "why": "Error code"
   },
   {
    "table": "holding_register",
    "address": 200,
    "why": "Allow charging"
   },
   {
    "table": "holding_register",
    "address": 299,
    "why": "Set charge current (not saved)"
   },
   {
    "table": "input_register",
    "address": 205,
    "why": "Phases available"
   }
  ],
  "enable": "Allow API access in the go-eCharger app under Advanced Settings, then restart the charger. Needs firmware 0.40 or newer.",
  "watchdog": null,
  "quirks": [
   "Addresses are 0-based; 1-based tools need +1.",
   "Unit ID is 1 and the port is 502 over WLAN."
  ],
  "setup": [
   "Enable API access in the app (Advanced Settings) and reboot the charger.",
   "Connect to the charger IP on TCP port 502, unit ID 1."
  ],
  "gotchas": [
   "Use AMPERE_VOLATILE (299) for frequent changes; AMPERE_EEPROM (300) is stored in EEPROM with roughly 100,000 write cycles.",
   "AMPERE_VOLATILE resets to the stored EEPROM value at the next boot."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/go-e/go-echarger-api-v1",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}