EV charger · Modbus register map

go-e go-eCharger (Modbus TCP, API v2) Modbus register map

Updated 17 November 2026

Short answer

go-eCharger wallboxes on the v2 API expose a Modbus TCP server on port 502 once it is enabled in the app or over the HTTP API. This map covers the single-register status and control points: charging state, errors, charge permission, access mode, cable lock, current setpoints, push-button current levels, phase switch mode and force state.

This page lists 23 Modbus registers for the go-e go-eCharger (Modbus TCP, API v2) — 20 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from go-e’s own free documentation (linked below) and checked against it.

Manufacturer
go-e
Model
go-eCharger (Modbus TCP, API v2)
Equipment type
EV charger
Registers
23 (20 writable)
Transport
Modbus TCP
Default unit ID
Not stated
TCP port
502
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
Also known as
go-eCharger Modbus API v2, go-e Charger
Source document
go-eCharger API v2 - Modbus (modbus-en.md) · go-eCharger-API-v2 modbus-en.md (main branch)
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: go-e go-eCharger (Modbus TCP, API v2)

Integration in brief

Enable Modbus, then connect to TCP port 502. Read CAR_STATE (100) and ERROR (107), allow charging with ALLOW (200) and set the current with AMPERE_VOLATILE (299) for dynamic load management, writing with function 16.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 100CAR_STATEUINT16Charging stateRead
IR 107ERRORUINT16Error codeRead
HR 200ALLOWUINT16Allow chargingRead/write
HR 299AMPERE_VOLATILEUINT16Set charge current (not saved)Read/write
HR 337FORCE_STATEUINT16Force charging on/offRead/write

Enable Modbus control & writes

Turn on Modbus in the app (Internet tab > Advanced Settings > Modbus) or with the HTTP API key men=true, e.g. /api/set?men=true. The port is set with msp (reboot needed).

Byte order & addressing

Network setup

Watch out for

go-e go-eCharger (Modbus TCP, API v2) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

23 of 23 shown
go-e go-eCharger (Modbus TCP, API v2) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR100doc 30101 (100)CAR_STATECharging state as seen on the PWM pilot.UINT16Read0 = Unknown / charging station defective; 1 = Ready, no car; 2 = Car is charging; 3 = Waiting for car; 4 = Charging finished, car still connected
IR101doc 30102 (101)PP_CABLEType 2 cable current coding: 13-32 A, 0 = no cable.UINT16ARead
IR107doc 30108 (107)ERRORError code.UINT16Read1 = RCCB (residual current breaker); 3 = Phase disturbance; 8 = No ground detected; 10 = Internal (others, default)
HR200doc 40201 (200)ALLOWWhether the PWM charging signal is allowed.UINT16Read/write0 = No; 1 = Yes
HR201doc 40202 (201)ACCESS_STATEAccess control mode.UINT16Read/write0 = Open; 1 = RFID / app needed; 2 = Electricity price / automatic; 3 = Scheduler
HR204doc 40205 (204)CABLE_LOCK_MODEUINT16Read/write0 = Lock while car is connected; 1 = Unlock automatically after charging; 2 = Always locked
HR206doc 40207 (206)LED_BRIGHTNESS0 = off, 255 = maximum.UINT16Read/write
HR207doc 40208 (207)LED_SAVE_ENERGYLEDs switch off automatically after 10 s when on.UINT16Read/write0 = Off; 1 = On
HR208doc 40209 (208)ELECTRICITY_PRICES_HOURSMinimum hours to charge in electricity-price mode.UINT16hRead/write
HR209doc 40210 (209)ELECTRICITY_PRICES_FINISHEDHour of day by which price-mode charging must be done.UINT16Read/write
HR210doc 40211 (210)ELECTRICITY_PRICES_ZONEaWATTar price zone.UINT16Read/write0 = Austria; 1 = Germany
HR211doc 40212 (211)AMPERE_MAXUpper limit for the current setting.UINT16ARead/write
HR212doc 40213 (212)AMPERE_L1Push-button current level 1: 6-32 A, 0 = skipped.UINT16ARead/write
HR213doc 40214 (213)AMPERE_L2Push-button current level 2: 6-32 A, 0 = skipped.UINT16ARead/write
HR214doc 40215 (214)AMPERE_L3Push-button current level 3: 6-32 A, 0 = skipped.UINT16ARead/write
HR215doc 40216 (215)AMPERE_L4Push-button current level 4: 6-32 A, 0 = skipped.UINT16ARead/write
HR216doc 40217 (216)AMPERE_L5Push-button current level 5: 6-32 A, 0 = skipped.UINT16ARead/write
HR217doc 40218 (217)CLOUD_DISABLEDUINT16Read/write0 = Cloud enabled; 1 = Cloud disabled
HR218doc 40219 (218)NORWAY_MODEDisables ground detection; for IT networks only.UINT16Read/write0 = Off (ground detection on); 1 = On (no ground detection)
HR299doc 40300 (299)AMPERE_VOLATILECharge current 6-32 A, not saved; use for energy management.UINT16ARead/write
HR300doc 40301 (300)AMPERE_EEPROMCharge current 6-32 A, saved to EEPROM (about 100,000 writes).UINT16ARead/write
HR332doc 40333 (332)PHASE_SWITCH_MODESame as API key psm; accepts 0, 1 or 2 (firmware 55.5+).UINT16Read/write
HR337doc 40338 (337)FORCE_STATESame as API key frc (firmware 55.6+).UINT16Read/write0 = Neutral; 1 = Off; 2 = On

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the go-e go-eCharger (Modbus TCP, API v2)

What Modbus registers does the go-e go-eCharger (Modbus TCP, API v2) have?

This map lists 23 registers: 3 input registers, 20 holding registers. 20 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the go-e go-eCharger (Modbus TCP, API v2) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The table prints each register as Modicon number plus wire address, e.g. '40300 (299)' and '30101 (100)'. The number in brackets goes in the request PDU.

What are the minimum Modbus registers to integrate the go-e go-eCharger (Modbus TCP, API v2)?

Start with IR 100 CAR_STATE (Charging state); IR 107 ERROR (Error code); HR 200 ALLOW (Allow charging); HR 299 AMPERE_VOLATILE (Set charge current (not saved)); HR 337 FORCE_STATE (Force charging on/off).

How do I enable Modbus control of the go-e go-eCharger (Modbus TCP, API v2)?

Turn on Modbus in the app (Internet tab > Advanced Settings > Modbus) or with the HTTP API key men=true, e.g. /api/set?men=true. The port is set with msp (reboot needed).

Where is the official go-e go-eCharger (Modbus TCP, API v2) Modbus documentation?

The source is go-eCharger API v2 - Modbus (modbus-en.md) (go-eCharger-API-v2 modbus-en.md (main branch)), published free by go-e at https://raw.githubusercontent.com/goecharger/go-eCharger-API-v2/main/modbus-en.md.

More go-e Modbus register maps

Source: go-eCharger API v2 - Modbus (modbus-en.md) · go-eCharger-API-v2 modbus-en.md (main branch). Register numbers, types, scaling and units are reproduced as published; descriptions are our own.