 "manufacturer": "inepro Metering",
 "manufacturer_slug": "inepro-metering",
 "model": "PRO380-Eichrecht three-phase energy meter",
 "model_slug": "pro380-eichrecht",
 "short_model": "PRO380-Eichrecht",
 "aliases": [
  "PRO380 Eichrecht",
  "PRO380-E",
  "inepro PRO380 Eichrecht"
 ],
 "equipment_type": "Energy meter",
 "applies_to": "PRO380-Eichrecht direct-connected 3x230/400 V, 40 A meter (MID + German MessEV calibration law, for EV chargers), user manual version 1.45, September 2025.",
 "summary": "The PRO380-Eichrecht is inepro's German calibration-law (Eichrecht) version of the PRO380, built into AC EV chargers. It has two RS485 Modbus RTU ports: RS485-1 for full access and RS485-2 as a read-only secondary. All registers are holding registers at hex addresses; live values are FLOAT32 in V, A, W, var and VA, and energy counters are INT32 in Wh by default. This map has its own register set and differs from the PRO380-Mod map.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 9600,
  "parity": "Even",
  "data_bits": null,
  "stop_bits": null,
  "tcp_port": null
 },
 "addressing": {
  "convention": "hex 0-based",
  "note": "The map is headed 'Holding register address (hex)'. The hex value goes on the wire unchanged, so 0x5012 (total active power) is decimal 20498, read with function 03."
 },
 "default_word_order": "ABCD",
 "firmware": null,
 "source": {
  "title": "PRO380-Eichrecht electricity meter - Full user manual EN",
  "doc_number": "User Manual PRO380-Eichrecht Version 1.45",
  "revision_date": "2025-09",
  "url": "https://cdn.prod.website-files.com/6617f74190bf0a53bfd776e8/68d24b7e4c7016ae54d2bc9a_PRO380-Eichrecht%20electricity%20meter%20-%20Full%20user%20manual%20EN.pdf",
  "pages": "RS485 spec section 4.5; terminals section 4.7; register map section 9.1 (pp. 18-24); error codes section 9.2 (p. 24); configurator energy data type and combination code (pp. 26-27)"
 },
 "notes": [
  "Energy data type (configurator section): default INT32, big-endian 32-bit integers in 1 Wh units over two holding registers; the alternative FLOAT32 is 'float ABCD' in kWh. Switch with 4026h (0 = FLOAT32, 1 = INT32). The energy rows here assume the default INT32.",
  "Word order for the FLOAT32 live values is taken from the manual's description of its FLOAT32 type as 'float ABCD' (high word first).",
  "The map prints the unit 'var' for reactive energy counters 6024h-6046h; they are energy counters and are listed here as varh, as on the quadrant rows (6063h on).",
  "Left out: serial number and product id (packed BCD), meter code (marked TODO in the manual), phase direction (ASCII), CT ratio and S0 output rate (marked not used), checksums and active status word, LCD custom fields, the waveform sample buffer (47FDh-4800h) and the blocking 'update wait' register 4081h.",
  "Two power-peak registers (5064h and 5066h) are both named 'Previous Forward Active Power Peak' in the source; 5066h is most likely the reverse one, but the name is copied as printed.",
  "The RS485 spec lists baud rates 1200-115200, address range 0-247 and up to 31 meters per bus."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 16387,
   "documented": "0x4003",
   "name": "Modbus ID",
   "description": "Device address 1-247.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16388,
   "documented": "0x4004",
   "name": "Baud rate",
   "description": "Baud rate code.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "3": "1200",
    "4": "2400",
    "5": "4800",
    "6": "9600",
    "7": "19200",
    "8": "38400",
    "9": "57600",
    "10": "115200"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16389,
   "documented": "0x4005",
   "name": "Protocol version",
   "description": "COM firmware version, e.g. 1.0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16391,
   "documented": "0x4007",
   "name": "Software version",
   "description": "MID firmware version.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16393,
   "documented": "0x4009",
   "name": "Hardware version",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16395,
   "documented": "0x400b",
   "name": "Meter amps",
   "description": "Maximum current Imax, e.g. 40 A.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16399,
   "documented": "0x400f",
   "name": "Combination code",
   "description": "How forward and reverse energy are combined into the total counters.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Forward only",
    "2": "Reverse only",
    "3": "Forward + reverse",
    "4": "Forward - reverse"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16400,
   "documented": "0x4010",
   "name": "LCD cycle time",
   "description": "Minimum display time per LCD message (default 3 s).",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16401,
   "documented": "0x4011",
   "name": "Parity",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Even",
    "2": "None",
    "3": "Odd"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16405,
   "documented": "0x4015",
   "name": "Error code",
   "description": "Error bitfield; also shown on the LCD.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "MID firmware CRC error",
    "1": "EEPROM communication error",
    "2": "EEPROM data corruption",
    "3": "Measurement hardware error",
    "4": "Meter failed to calibrate",
    "7": "Production not marked completed",
    "8": "Firmware CRC error",
    "9": "Provisioning data error"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16406,
   "documented": "0x4016",
   "name": "Power on/off counter",
   "description": "Power cycle count; write 0 to clear.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16407,
   "documented": "0x4017",
   "name": "Total power quadrant",
   "description": "Quadrant 1-4 of total power.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16408,
   "documented": "0x4018",
   "name": "L1 power quadrant",
   "description": "Quadrant 1-4.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16409,
   "documented": "0x4019",
   "name": "L2 power quadrant",
   "description": "Quadrant 1-4.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16410,
   "documented": "0x401a",
   "name": "L3 power quadrant",
   "description": "Quadrant 1-4.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16422,
   "documented": "0x4026",
   "name": "Energy data type",
   "description": "Encoding of the energy counters 6000h-6FFFh.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "FLOAT32 (kWh)",
    "1": "INT32 (Wh, default)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16512,
   "documented": "0x4080",
   "name": "Measurement update check",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Busy",
    "1": "Measurement data ready"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16514,
   "documented": "0x4082",
   "name": "Phase order error status",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "OK",
    "1": "Invalid phase order"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16515,
   "documented": "0x4083",
   "name": "3-wire detection status",
   "description": "Detected connection type.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "3P4W",
    "1": "3P3W"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16752,
   "documented": "0x4170",
   "name": "Measurement interval",
   "description": "Internal update interval (default 300 ms).",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "600 ms",
    "1": "300 ms",
    "2": "100 ms",
    "3": "50 ms"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16753,
   "documented": "0x4171",
   "name": "Backlight level",
   "description": "0-100.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16754,
   "documented": "0x4172",
   "name": "Power factor sign mode",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "IEC",
    "1": "IEEE",
    "2": "Positive"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16755,
   "documented": "0x4173",
   "name": "MID firmware updates",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Allowed",
    "1": "Disabled"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16756,
   "documented": "0x4174",
   "name": "COM firmware updates",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Allowed",
    "1": "Disabled"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16757,
   "documented": "0x4175",
   "name": "Peak power interval",
   "description": "Peak detection interval in minutes; 0 = off, 1-60 (default 15).",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20480,
   "documented": "0x5000",
   "name": "Voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20482,
   "documented": "0x5002",
   "name": "Voltage L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20484,
   "documented": "0x5004",
   "name": "Voltage L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20486,
   "documented": "0x5006",
   "name": "Voltage L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20488,
   "documented": "0x5008",
   "name": "Grid Frequency",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Hz",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20490,
   "documented": "0x500a",
   "name": "Current",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20492,
   "documented": "0x500c",
   "name": "Current L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20494,
   "documented": "0x500e",
   "name": "Current L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20496,
   "documented": "0x5010",
   "name": "Current L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20498,
   "documented": "0x5012",
   "name": "Total Active Power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20500,
   "documented": "0x5014",
   "name": "Active Power L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20502,
   "documented": "0x5016",
   "name": "Active Power L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20504,
   "documented": "0x5018",
   "name": "Active Power L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20506,
   "documented": "0x501a",
   "name": "Total reactive power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20508,
   "documented": "0x501c",
   "name": "L1 reactive power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20510,
   "documented": "0x501e",
   "name": "L2 reactive power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20512,
   "documented": "0x5020",
   "name": "L3 reactive power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20514,
   "documented": "0x5022",
   "name": "Total Apparent Power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20516,
   "documented": "0x5024",
   "name": "L1 Apparent Power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20518,
   "documented": "0x5026",
   "name": "L2 Apparent Power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20520,
   "documented": "0x5028",
   "name": "L3 Apparent Power",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20522,
   "documented": "0x502a",
   "name": "Power Factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20524,
   "documented": "0x502c",
   "name": "L1 Power Factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20526,
   "documented": "0x502e",
   "name": "L2 Power Factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20528,
   "documented": "0x5030",
   "name": "L3 Power Factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20530,
   "documented": "0x5032",
   "name": "L1-L2 Voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20532,
   "documented": "0x5034",
   "name": "L1-L3 Voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20534,
   "documented": "0x5036",
   "name": "L2-L3 Voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20536,
   "documented": "0x5038",
   "name": "LL Average Voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20538,
   "documented": "0x503a",
   "name": "Neutral Current",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20540,
   "documented": "0x503c",
   "name": "Temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20542,
   "documented": "0x503e",
   "name": "L1 Voltage THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20544,
   "documented": "0x5040",
   "name": "L2 Voltage THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20546,
   "documented": "0x5042",
   "name": "L3 Voltage THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20548,
   "documented": "0x5044",
   "name": "L1 Current THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20550,
   "documented": "0x5046",
   "name": "L2 Current THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20552,
   "documented": "0x5048",
   "name": "L3 Current THD",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20576,
   "documented": "0x5060",
   "name": "Forward Active Power Peak",
   "description": "Write 0 to clear.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20578,
   "documented": "0x5062",
   "name": "Reverse Active Power Peak",
   "description": "Write 0 to clear.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20580,
   "documented": "0x5064",
   "name": "Previous Forward Active Power Peak",
   "description": "Value before the last clear.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20582,
   "documented": "0x5066",
   "name": "Previous Forward Active Power Peak",
   "description": "Value before the last clear.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20608,
   "documented": "0x5080",
   "name": "Minutes above 70 degrees",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20610,
   "documented": "0x5082",
   "name": "Minutes above max current",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24576,
   "documented": "0x6000",
   "name": "Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24578,
   "documented": "0x6002",
   "name": "T1 Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24580,
   "documented": "0x6004",
   "name": "T2 Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24582,
   "documented": "0x6006",
   "name": "L1 Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24584,
   "documented": "0x6008",
   "name": "L2 Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24586,
   "documented": "0x600a",
   "name": "L3 Total Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24588,
   "documented": "0x600c",
   "name": "Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24590,
   "documented": "0x600e",
   "name": "T1 Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24592,
   "documented": "0x6010",
   "name": "T2 Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24594,
   "documented": "0x6012",
   "name": "L1 Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24596,
   "documented": "0x6014",
   "name": "L2 Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24598,
   "documented": "0x6016",
   "name": "L3 Forward Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24600,
   "documented": "0x6018",
   "name": "Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24602,
   "documented": "0x601a",
   "name": "T1 Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24604,
   "documented": "0x601c",
   "name": "T2 Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24606,
   "documented": "0x601e",
   "name": "L1 Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24608,
   "documented": "0x6020",
   "name": "L2 Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24610,
   "documented": "0x6022",
   "name": "L3 Reverse Active Energy",
   "description": "INT32 Wh when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24612,
   "documented": "0x6024",
   "name": "Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24614,
   "documented": "0x6026",
   "name": "T1 Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24616,
   "documented": "0x6028",
   "name": "T2 Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24618,
   "documented": "0x602a",
   "name": "L1 Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24620,
   "documented": "0x602c",
   "name": "L2 Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24622,
   "documented": "0x602e",
   "name": "L3 Total Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24624,
   "documented": "0x6030",
   "name": "Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24626,
   "documented": "0x6032",
   "name": "T1 Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24628,
   "documented": "0x6034",
   "name": "T2 Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24630,
   "documented": "0x6036",
   "name": "L1 Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24632,
   "documented": "0x6038",
   "name": "L2 Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24634,
   "documented": "0x603a",
   "name": "L3 Forward Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24636,
   "documented": "0x603c",
   "name": "Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24638,
   "documented": "0x603e",
   "name": "T1 Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24640,
   "documented": "0x6040",
   "name": "T2 Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24642,
   "documented": "0x6042",
   "name": "L1 Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24644,
   "documented": "0x6044",
   "name": "L2 Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24646,
   "documented": "0x6046",
   "name": "L3 Reverse Reactive Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24648,
   "documented": "0x6048",
   "name": "Tariff",
   "description": "Active tariff.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "T1",
    "1": "T2"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24649,
   "documented": "0x6049",
   "name": "Resettable day counter",
   "description": "Write 0 to clear the day counter.",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24675,
   "documented": "0x6063",
   "name": "Reactive Energy Q1 (total)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24677,
   "documented": "0x6065",
   "name": "Reactive Energy Q1 (T1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24679,
   "documented": "0x6067",
   "name": "Reactive Energy Q1 (T2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24685,
   "documented": "0x606d",
   "name": "Reactive Energy Q2 (total)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24687,
   "documented": "0x606f",
   "name": "Reactive Energy Q2 (T1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24689,
   "documented": "0x6071",
   "name": "Reactive Energy Q2 (T2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24695,
   "documented": "0x6077",
   "name": "Reactive Energy Q3 (total)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24697,
   "documented": "0x6079",
   "name": "Reactive Energy Q3 (T1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24699,
   "documented": "0x607b",
   "name": "Reactive Energy Q3 (T2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24705,
   "documented": "0x6081",
   "name": "Reactive Energy Q4 (total)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24707,
   "documented": "0x6083",
   "name": "Reactive Energy Q4 (T1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24709,
   "documented": "0x6085",
   "name": "Reactive Energy Q4 (T2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24721,
   "documented": "0x6091",
   "name": "Reactive Energy Q1 (L1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24723,
   "documented": "0x6093",
   "name": "Reactive Energy Q1 (L2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24725,
   "documented": "0x6095",
   "name": "Reactive Energy Q1 (L3)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24727,
   "documented": "0x6097",
   "name": "Reactive Energy Q2 (L1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24729,
   "documented": "0x6099",
   "name": "Reactive Energy Q2 (L2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24731,
   "documented": "0x609b",
   "name": "Reactive Energy Q2 (L3)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24733,
   "documented": "0x609d",
   "name": "Reactive Energy Q3 (L1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24735,
   "documented": "0x609f",
   "name": "Reactive Energy Q3 (L2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24737,
   "documented": "0x60a1",
   "name": "Reactive Energy Q3 (L3)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24739,
   "documented": "0x60a3",
   "name": "Reactive Energy Q4 (L1)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24741,
   "documented": "0x60a5",
   "name": "Reactive Energy Q4 (L2)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24743,
   "documented": "0x60a7",
   "name": "Reactive Energy Q4 (L3)",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "varh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24745,
   "documented": "0x60a9",
   "name": "Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24747,
   "documented": "0x60ab",
   "name": "T1 Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24749,
   "documented": "0x60ad",
   "name": "T2 Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24751,
   "documented": "0x60af",
   "name": "L1 Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24833,
   "documented": "0x6101",
   "name": "L2 Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24835,
   "documented": "0x6103",
   "name": "L3 Total Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24837,
   "documented": "0x6105",
   "name": "Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24839,
   "documented": "0x6107",
   "name": "T1 Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24841,
   "documented": "0x6109",
   "name": "T2 Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24843,
   "documented": "0x610b",
   "name": "L1 Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24845,
   "documented": "0x610d",
   "name": "L2 Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24847,
   "documented": "0x610f",
   "name": "L3 Forward Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24849,
   "documented": "0x6111",
   "name": "Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24851,
   "documented": "0x6113",
   "name": "T1 Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24853,
   "documented": "0x6115",
   "name": "T2 Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24855,
   "documented": "0x6117",
   "name": "L1 Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24857,
   "documented": "0x6119",
   "name": "L2 Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24859,
   "documented": "0x611b",
   "name": "L3 Reverse Apparent Energy",
   "description": "INT32 when 4026h = 1 (default).",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VAh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 25088,
   "documented": "0x6200",
   "name": "Previous day counter",
   "description": "Day counter value before the last clear.",
   "data_type": "INT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Wh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Connect to RS485-1 (terminals 22/23), poll unit 1 at 9600 baud, even parity with function 03. Read live values as ABCD floats from 5000h and energy as big-endian INT32 Wh from 6000h.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 20482,
    "why": "Voltage L1"
   },
   {
    "table": "holding_register",
    "address": 20492,
    "why": "Current L1"
   },
   {
    "table": "holding_register",
    "address": 20498,
    "why": "Total active power (W)"
   },
   {
    "table": "holding_register",
    "address": 20522,
    "why": "Power factor"
   },
   {
    "table": "holding_register",
    "address": 20488,
    "why": "Grid frequency"
   },
   {
    "table": "holding_register",
    "address": 24588,
    "why": "Forward (import) active energy"
   },
   {
    "table": "holding_register",
    "address": 24600,
    "why": "Reverse (export) active energy"
   },
   {
    "table": "holding_register",
    "address": 16405,
    "why": "Error bitfield"
   }
  ],
  "enable": "No enable step is described. Settings (ID, baud, parity, energy data type, combination code) can be written over Modbus or with inepro's EichrechtMeterConfig tool.",
  "watchdog": null,
  "quirks": [
   "Addresses are hex: 0x5012 is decimal 20498.",
   "Power is in W/var/VA here, unlike the PRO380-Mod which reports kW.",
   "Energy is INT32 Wh by default; setting 4026h = 0 switches to FLOAT32 kWh, which keeps only about 6 significant digits.",
   "Baud rate is written as a code (6 = 9600), not as the number."
  ],
  "setup": [
   "RS485-1 A/B on terminals 22/23 is the primary port; RS485-2 on 24/25 is read-only.",
   "Defaults: Modbus ID 1, 9600 baud, even parity.",
   "The optical port uses fixed settings: 4800 baud, even parity, ID 1."
  ],
  "gotchas": [
   "Forward and reverse counters are always positive; the combination code only affects the total counters, not power."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/inepro-metering/pro380-eichrecht",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}