 "manufacturer": "KROHNE",
 "manufacturer_slug": "krohne",
 "model": "IFC 100 electromagnetic flow converter (Modbus RTU)",
 "model_slug": "ifc-100",
 "short_model": "IFC 100",
 "aliases": [
  "IFC100",
  "IFC 100 Modbus",
  "KROHNE IFC 100"
 ],
 "equipment_type": "Sensor (electromagnetic flowmeter)",
 "applies_to": "IFC 100 signal converter with the Modbus option, supplementary instructions 4001410101 R01 (08/2014).",
 "summary": "The IFC 100 is a KROHNE signal converter for electromagnetic flowmeters. With the Modbus option it is an RS-485 Modbus RTU slave. This map covers flow, temperature, conductivity and diagnosis floats, the two double-float totalisers, counter and filter settings, calibration values, serial parameters and the control coils.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 19200,
  "parity": "Even",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "The manual lists protocol addresses and says they go into the request unchanged: input register 30006 is requested as start address 30006 (0x7536). The same registers are mirrored lower for masters that cannot use high addresses (30000-38998 -> 0-8998, 20000-20998 -> 9000-9998, 40000-49998 -> 0-9998)."
 },
 "default_word_order": "ABCD",
 "firmware": "Electronic revision ER 3.0.xx, Modbus version 1.0.xx",
 "source": {
  "title": "IFC 100 Supplementary instructions - Description of Modbus interface",
  "doc_number": "4001410101 R01",
  "revision_date": "2014-08",
  "url": "https://cdn.krohne.com/archive/AD_IFC100_Modbus_en_140728_4001410101_R01.pdf",
  "pages": "Serial settings p. 6; addressing pp. 8-9; coils pp. 10-11; input registers p. 12; holding registers pp. 13-16; calibration pp. 17-19"
 },
 "notes": [
  "Data format is selectable (C5.8.4 or holding 50004): Big Endian, which the manual defines as MSB first for the data bytes, is the default, so 32-bit floats and 64-bit doubles are listed ABCD. With Little Endian (LSB first) selected the whole value is byte-reversed. The manual gives no worked byte example.",
  "Input registers 30000-30034 can also be read at 0-34, and holding registers 40000-49998 at 0-9998; only the primary addresses are listed.",
  "Left out: long status sensor/device (30032 / 30034, byte[4]) because the bit meanings are not given in this document; 'no function' and 'not used' registers.",
  "Factory serial settings: address 1, 19200 baud, even parity, 1 stop bit, Big Endian, 0 ms response delay.",
  "byte and word types in the holding tables each occupy one register and are listed as UINT16."
 ],
 "registers": [
  {
   "table": "coil",
   "address": 1000,
   "documented": "1000",
   "name": "Cold start",
   "description": "Write 1 to cold-start the converter.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 1001,
   "documented": "1001",
   "name": "Warm start",
   "description": "Write 1 to warm-start; also activates new calibration values.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 1002,
   "documented": "1002",
   "name": "Error reset",
   "description": "Write 1 to reset errors.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 2000,
   "documented": "2000",
   "name": "Zero calibration",
   "description": "Write 1 to start; reads 1 while running.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 2001,
   "documented": "2001",
   "name": "Coil temperature calibration",
   "description": "Write 1 to start; reads 1 while running.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 2002,
   "documented": "2002",
   "name": "Electrode factor calibration",
   "description": "Write 1 to start; reads 1 while running.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 3000,
   "documented": "3000",
   "name": "Counter 1 start/stop",
   "description": "Write 1 start, 0 stop; reads 1 while running.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 3001,
   "documented": "3001",
   "name": "Counter 2 start/stop",
   "description": "Write 1 start, 0 stop; reads 1 while running.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 3003,
   "documented": "3003",
   "name": "Counter 1 reset",
   "description": "Write 1 to reset.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 3004,
   "documented": "3004",
   "name": "Counter 2 reset",
   "description": "Write 1 to reset.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 20000,
   "documented": "20000",
   "name": "Calibration result",
   "description": "Result of the last calibration function (first float).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30000,
   "documented": "30000",
   "name": "Flow speed",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30002,
   "documented": "30002",
   "name": "Volume flow",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m3/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30004,
   "documented": "30004",
   "name": "Mass flow",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kg/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30006,
   "documented": "30006",
   "name": "Coil temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "K",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30008,
   "documented": "30008",
   "name": "Conductivity",
   "description": "Only measured when empty-pipe/conductivity function (42003) is on.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "S/m",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30010,
   "documented": "30010",
   "name": "Diagnosis value",
   "description": "Meaning set by 42011: electrode noise (m/s) or terminal 2/3 DC (V).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30012,
   "documented": "30012",
   "name": "Display channel 1",
   "description": "First line of the first measurement screen, SI units.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30014,
   "documented": "30014",
   "name": "Display channel 2",
   "description": "First line of the second measurement screen, SI units.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30016,
   "documented": "30016",
   "name": "Operating time",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30020,
   "documented": "30020",
   "name": "Counter 1",
   "description": "m3 or kg, per counter 1 measurement.",
   "data_type": "FLOAT64",
   "length": 4,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 30024,
   "documented": "30024",
   "name": "Counter 2",
   "description": "m3 or kg, per counter 2 measurement.",
   "data_type": "FLOAT64",
   "length": 4,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40000,
   "documented": "40000",
   "name": "Counter 1 function",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Sum counter",
    "2": "+ counter",
    "3": "- counter",
    "0": "Off"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40001,
   "documented": "40001",
   "name": "Counter 1 measurement",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "21": "Volume flow",
    "22": "Mass flow"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40002,
   "documented": "40002",
   "name": "Counter 2 function",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Sum counter",
    "2": "+ counter",
    "3": "- counter",
    "0": "Off"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40003,
   "documented": "40003",
   "name": "Counter 2 measurement",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "21": "Volume flow",
    "22": "Mass flow"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41000,
   "documented": "41000",
   "name": "Counter 1 low flow cutoff",
   "description": "m3/s or kg/s.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41002,
   "documented": "41002",
   "name": "Counter 1 time constant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41004,
   "documented": "41004",
   "name": "Counter 1 value (set/read)",
   "description": "m3 or kg.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41006,
   "documented": "41006",
   "name": "Counter 2 low flow cutoff",
   "description": "m3/s or kg/s.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41008,
   "documented": "41008",
   "name": "Counter 2 time constant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41010,
   "documented": "41010",
   "name": "Counter 2 value (set/read)",
   "description": "m3 or kg.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41018,
   "documented": "41018",
   "name": "Counter 1 preset",
   "description": "m3 or kg.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41020,
   "documented": "41020",
   "name": "Counter 2 preset",
   "description": "m3 or kg.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42000,
   "documented": "42000",
   "name": "Flow direction",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Normal",
    "1": "Reverse"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42001,
   "documented": "42001",
   "name": "Pulse filter",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On",
    "2": "Automatic"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42002,
   "documented": "42002",
   "name": "Noise filter",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42003,
   "documented": "42003",
   "name": "Empty pipe / conductivity",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "Conductivity",
    "2": "Cond. + empty pipe (S)",
    "3": "Cond. + empty pipe (F)",
    "4": "Cond. + empty pipe (I)"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42009,
   "documented": "42009",
   "name": "Electrode noise",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42010,
   "documented": "42010",
   "name": "Settling of field",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42011,
   "documented": "42011",
   "name": "Diagnosis value selection",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "25": "Off",
    "31": "Electrode noise",
    "8": "Terminal 2 DC",
    "9": "Terminal 3 DC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43000,
   "documented": "43000",
   "name": "Limitation low",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43002,
   "documented": "43002",
   "name": "Limitation high",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43004,
   "documented": "43004",
   "name": "Time constant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43006,
   "documented": "43006",
   "name": "Pulse width (pulse filter on)",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43008,
   "documented": "43008",
   "name": "Pulse limitation",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43010,
   "documented": "43010",
   "name": "Noise level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43012,
   "documented": "43012",
   "name": "Noise suppression",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43014,
   "documented": "43014",
   "name": "Low flow cutoff",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43016,
   "documented": "43016",
   "name": "Limit empty pipe",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "S/m",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43022,
   "documented": "43022",
   "name": "Limit electrode noise",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43024,
   "documented": "43024",
   "name": "Zero point",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43026,
   "documented": "43026",
   "name": "Coil resistance Rsp,20",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Ohm",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43028,
   "documented": "43028",
   "name": "Coil temperature calibration point",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "K",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43030,
   "documented": "43030",
   "name": "Coil resistance calibration point",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Ohm",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43032,
   "documented": "43032",
   "name": "Electrode factor EF",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "m",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43034,
   "documented": "43034",
   "name": "Conductivity calibration point",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "S/m",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43036,
   "documented": "43036",
   "name": "Conductivity calibration point (second copy)",
   "description": "Write the same target to 43034 and 43036.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "S/m",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43038,
   "documented": "43038",
   "name": "Pulse width (pulse filter automatic)",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 50000,
   "documented": "50000",
   "name": "Baud rate",
   "description": "1200-115200; default 19200.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "baud",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 50002,
   "documented": "50002",
   "name": "Slave address",
   "description": "1-247, default 1.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 50003,
   "documented": "50003",
   "name": "Parity",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Even (default)",
    "1": "Odd",
    "3": "None"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 50004,
   "documented": "50004",
   "name": "Data format",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Big endian",
    "2": "Little endian"
   },
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Read input registers 30000-30027 (function 04) in one block for flow speed, volume and mass flow, temperature and the two double-float counters. Use coils (function 05) for counter start/stop/reset and error reset.",
  "minimum_registers": [
   {
    "table": "input_register",
    "address": 30002,
    "why": "Volume flow"
   },
   {
    "table": "input_register",
    "address": 30004,
    "why": "Mass flow"
   },
   {
    "table": "input_register",
    "address": 30000,
    "why": "Flow speed"
   },
   {
    "table": "input_register",
    "address": 30020,
    "why": "Counter 1"
   },
   {
    "table": "input_register",
    "address": 30024,
    "why": "Counter 2"
   },
   {
    "table": "input_register",
    "address": 30006,
    "why": "Coil temperature"
   }
  ],
  "enable": "Set the Modbus slave address, baud rate, parity, data format and stop bits in converter menu C5.8 (or holding registers 50000-50004).",
  "watchdog": null,
  "quirks": [
   "Addresses are protocol addresses sent as printed (30000 is sent as 30000).",
   "Low mirror addresses exist for masters limited to 9999.",
   "Counters are 64-bit doubles."
  ],
  "setup": [
   "Defaults 19200 baud, even parity, 1 stop bit, address 1.",
   "Terminate both bus ends with 120 Ohm and bias the line at one point."
  ],
  "gotchas": [
   "New calibration values take effect only after a warm start (coil 1001), which takes up to 5 s.",
   "Write the conductivity target to both 43034 and 43036."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/krohne/ifc-100",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}