 "manufacturer": "Lumel",
 "manufacturer_slug": "lumel",
 "model": "ND20 network parameter meter",
 "model_slug": "nd20",
 "short_model": "ND20",
 "aliases": [
  "ND20",
  "ND20-xxxx"
 ],
 "equipment_type": "Power meter (panel network parameter meter)",
 "applies_to": "Lumel ND20 panel meter per the ND20 user's manual; registers 4056-4061 need firmware 1.09 or later and are not listed here.",
 "summary": "The ND20 is a 96x96 panel meter for 3- and 1-phase networks with an RS-485 Modbus RTU port. Each measured value is offered as a float in several register areas; this map uses the 7000 area (two 16-bit registers per value, high word first) plus the 4000 area of 16-bit settings, 32-bit energy counters and the status word.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 9600,
  "parity": "None",
  "data_bits": 8,
  "stop_bits": 2,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "Addresses are used as printed: the manual's example frames read 4000 as 0x0FA0, 7000 as 0x1B58 and 7500 as 0x1D4C. For the float area the 'documented' field shows the table's '6xxx/7xxx' pair; this map uses the 7xxx address."
 },
 "default_word_order": "ABCD",
 "firmware": null,
 "source": {
  "title": "Meter of network parameters ND20 type - User's manual",
  "doc_number": null,
  "revision_date": null,
  "url": "https://asset.conrad.com/media10/add/160267/c1/-/en/001384097ML02/upute-za-rukovanje-1384097-lumel-nd20-221100m1.pdf",
  "unofficial": true,
  "pages": "Serial link and example frames pp. 37-40; register map overview p. 41; Table 11 (4000 area) pp. 43-47; status bits p. 48; Table 12 (float areas) pp. 51-54 (printed page numbers)"
 },
 "notes": [
  "Source is Conrad's copy of the unaltered Lumel manual; Lumel's own site did not turn up a public copy of the full manual in two searches, though its quick-start guides point to lumel.com.pl.",
  "Float areas: 7000-7319 is two 16-bit registers per value with bytes 3-2-1-0 (ABCD), confirmed by the example frame that returns 41 20 00 00 = 10.0. The 6000 area holds the same values with bytes 1-0-3-2 (CDAB) and 7500 the same values as single 32-bit registers; only the 7000 area is listed here.",
  "Energy in the 4000 area is (high register x 65536 + low register) / 10 in kWh or kvarh, per the manual's formulas.",
  "Left out: 7054 (labelled 'Mean Tg factor of phase L1', which does not fit a 3-phase mean), the min/max area from 7128 on, harmonic energy overflow pairs 7112-7118, time registers 7120-7124, the averaged power archive 1000-1077, alarm and analog output setup 4001-4002 and 4012-4029, display configuration 4054-4056, and 4057 (its value list prints 3Ph/4W twice).",
  "Which quantities are valid depends on the connection (3Ph/4W, 3Ph/3W, 1Ph/2W); Table 12 marks phase values that are not available in 3-wire mode."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 4000,
   "documented": "4000",
   "name": "Password",
   "description": "Protection password, 0-60000.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4003,
   "documented": "4003",
   "name": "CT ratio",
   "description": "Current transformer ratio, 1-10000.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4004,
   "documented": "4004",
   "name": "VT ratio",
   "description": "Voltage transformer ratio stored x10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4005,
   "documented": "4005",
   "name": "Demand power synchronisation",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "15 min sliding window",
    "1": "15 min, clock-synchronised",
    "2": "30 min, clock-synchronised",
    "3": "60 min, clock-synchronised"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4011,
   "documented": "4011",
   "name": "Energy reset",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No change",
    "1": "Erase active energy",
    "2": "Erase reactive energy",
    "3": "Erase harmonic energy",
    "4": "Erase all energy"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4030,
   "documented": "4030",
   "name": "Modbus address",
   "description": "1-247.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4031,
   "documented": "4031",
   "name": "Transmission mode",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "8N2",
    "1": "8E1",
    "2": "8O1",
    "3": "8N1"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4032,
   "documented": "4032",
   "name": "Baud rate",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "4800",
    "1": "9600",
    "2": "19200",
    "3": "38400"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4033,
   "documented": "4033",
   "name": "Apply transmission settings",
   "description": "Write 1 to make new address/mode/baud take effect.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4038,
   "documented": "4038-4039",
   "name": "Imported active energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4040,
   "documented": "4040-4041",
   "name": "Exported active energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4042,
   "documented": "4042-4043",
   "name": "Reactive inductive energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4044,
   "documented": "4044-4045",
   "name": "Reactive capacitive energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4046,
   "documented": "4046-4047",
   "name": "Imported harmonic active energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4048,
   "documented": "4048-4049",
   "name": "Exported harmonic active energy",
   "description": "High word first; raw is in 0.1 kWh (kvarh) steps.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 0.1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4050,
   "documented": "4050",
   "name": "Status register",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Relay output on",
    "1": "RTC battery exhausted",
    "2": "Phase A voltage too low",
    "3": "Phase B voltage too low",
    "4": "Phase C voltage too low",
    "5": "Voltage too low to measure frequency",
    "6": "Frequency outside THD calculation window",
    "7": "Demand averaging interval not yet elapsed",
    "8": "Voltage range bit 0 (bits 9-8: 00 = 57.7 V, 01 = 230 V)",
    "9": "Voltage range bit 1",
    "10": "Current range (0 = 1 A, 1 = 5 A)",
    "11": "Phase sequence error",
    "12": "Energy value error",
    "13": "Parameter value error",
    "14": "Missing or faulty calibration",
    "15": "Non-volatile memory damaged"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4051,
   "documented": "4051-4052",
   "name": "Serial number",
   "description": "High word first.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4053,
   "documented": "4053",
   "name": "Program version",
   "description": "Firmware version x100.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7000,
   "documented": "6000/7000",
   "name": "Voltage L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7002,
   "documented": "6002/7002",
   "name": "Current L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7004,
   "documented": "6004/7004",
   "name": "Active power L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7006,
   "documented": "6006/7006",
   "name": "Reactive power L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7008,
   "documented": "6008/7008",
   "name": "Apparent power L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7010,
   "documented": "6010/7010",
   "name": "Power factor L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7012,
   "documented": "6012/7012",
   "name": "Tg phi L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7014,
   "documented": "6014/7014",
   "name": "Voltage L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7016,
   "documented": "6016/7016",
   "name": "Current L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7018,
   "documented": "6018/7018",
   "name": "Active power L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7020,
   "documented": "6020/7020",
   "name": "Reactive power L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7022,
   "documented": "6022/7022",
   "name": "Apparent power L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7024,
   "documented": "6024/7024",
   "name": "Power factor L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7026,
   "documented": "6026/7026",
   "name": "Tg phi L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7028,
   "documented": "6028/7028",
   "name": "Voltage L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7030,
   "documented": "6030/7030",
   "name": "Current L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7032,
   "documented": "6032/7032",
   "name": "Active power L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7034,
   "documented": "6034/7034",
   "name": "Reactive power L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7036,
   "documented": "6036/7036",
   "name": "Apparent power L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7038,
   "documented": "6038/7038",
   "name": "Power factor L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7040,
   "documented": "6040/7040",
   "name": "Tg phi L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7042,
   "documented": "6042/7042",
   "name": "Mean 3-phase voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7044,
   "documented": "6044/7044",
   "name": "Mean 3-phase current",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7046,
   "documented": "6046/7046",
   "name": "3-phase active power",
   "description": "Sum P1+P2+P3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7048,
   "documented": "6048/7048",
   "name": "3-phase reactive power",
   "description": "Sum Q1+Q2+Q3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "var",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7050,
   "documented": "6050/7050",
   "name": "3-phase apparent power",
   "description": "Sum S1+S2+S3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "VA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7052,
   "documented": "6052/7052",
   "name": "Mean power factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7056,
   "documented": "6056/7056",
   "name": "Frequency",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "Hz",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7058,
   "documented": "6058/7058",
   "name": "Voltage L1-L2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7060,
   "documented": "6060/7060",
   "name": "Voltage L2-L3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7062,
   "documented": "6062/7062",
   "name": "Voltage L3-L1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7064,
   "documented": "6064/7064",
   "name": "Mean phase-to-phase voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7066,
   "documented": "6066/7066",
   "name": "3-phase demand active power",
   "description": "Averaged over the 15/30/60 minute window set in register 4005.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7068,
   "documented": "6068/7068",
   "name": "Harmonic / THD U1",
   "description": "Selected harmonic or THD, per register 4006.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7070,
   "documented": "6070/7070",
   "name": "Harmonic / THD U2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7072,
   "documented": "6072/7072",
   "name": "Harmonic / THD U3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "V/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7074,
   "documented": "6074/7074",
   "name": "Harmonic / THD I1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7076,
   "documented": "6076/7076",
   "name": "Harmonic / THD I2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7078,
   "documented": "6078/7078",
   "name": "Harmonic / THD I3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A/%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7080,
   "documented": "6080/7080",
   "name": "Cos phi U1-I1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7082,
   "documented": "6082/7082",
   "name": "Cos phi U2-I2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7084,
   "documented": "6084/7084",
   "name": "Cos phi U3-I3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7086,
   "documented": "6086/7086",
   "name": "3-phase mean cos phi",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7088,
   "documented": "6088/7088",
   "name": "Angle U1-I1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "°",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7090,
   "documented": "6090/7090",
   "name": "Angle U2-I2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "°",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7092,
   "documented": "6092/7092",
   "name": "Angle U3-I3",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "°",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7094,
   "documented": "6094/7094",
   "name": "Neutral current",
   "description": "Calculated from the phase vectors.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7096,
   "documented": "6096/7096",
   "name": "Imported active energy, overflows",
   "description": "Count of rollovers of 7098.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "100 MWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7098,
   "documented": "6098/7098",
   "name": "Imported active energy",
   "description": "Counts up to 99999.9 kWh.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7100,
   "documented": "6100/7100",
   "name": "Exported active energy, overflows",
   "description": "Count of rollovers of 7102.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "100 MWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7102,
   "documented": "6102/7102",
   "name": "Exported active energy",
   "description": "Counts up to 99999.9 kWh.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7104,
   "documented": "6104/7104",
   "name": "Reactive inductive energy, overflows",
   "description": "Count of rollovers of 7106.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "100 Mvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7106,
   "documented": "6106/7106",
   "name": "Reactive inductive energy",
   "description": "Counts up to 99999.9 kvarh.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7108,
   "documented": "6108/7108",
   "name": "Reactive capacitive energy, overflows",
   "description": "Count of rollovers of 7110.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "100 Mvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7110,
   "documented": "6110/7110",
   "name": "Reactive capacitive energy",
   "description": "Counts up to 99999.9 kvarh.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "kvarh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7126,
   "documented": "6126/7126",
   "name": "Analog output value",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mA",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Read holding registers (FC03 or FC04) from 7000: 3 x 7 per-phase floats then 3-phase totals and frequency, high word first. Energy totals are the float pairs at 7096-7110 or the 32-bit counters at 4038-4045 (divide by 10).",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 7000,
    "why": "Voltage L1"
   },
   {
    "table": "holding_register",
    "address": 7002,
    "why": "Current L1"
   },
   {
    "table": "holding_register",
    "address": 7046,
    "why": "3-phase active power"
   },
   {
    "table": "holding_register",
    "address": 7052,
    "why": "Mean power factor"
   },
   {
    "table": "holding_register",
    "address": 7056,
    "why": "Frequency"
   },
   {
    "table": "holding_register",
    "address": 4038,
    "why": "Imported active energy"
   },
   {
    "table": "holding_register",
    "address": 4050,
    "why": "Status / error bits"
   }
  ],
  "enable": "The manual describes no separate Modbus enable; address, transmission mode and baud are set from the front menu or registers 4030-4032, then write 1 to 4033 to apply.",
  "watchdog": null,
  "quirks": [
   "The 6000 area is low word first, the 7000 area high word first: pick one and stick to it.",
   "Read at most 41 32-bit or 82 16-bit registers per request.",
   "Powers are in W, var and VA, not kW."
  ],
  "setup": [
   "Factory settings: address 1, 9600 baud, 8N2.",
   "Maximum response time is 600 ms."
  ],
  "gotchas": [
   "The 7096-7110 energies come as an overflow count (100 MWh) plus a counter that rolls at 99999.9 kWh."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/lumel/nd20",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}