 "manufacturer": "Machine Saver",
 "manufacturer_slug": "machine-saver",
 "model": "TriVibe vibration and temperature sensor (Modbus RTU)",
 "model_slug": "trivibe",
 "short_model": "TriVibe",
 "aliases": [
  "TriVibe",
  "Machine Saver TriVibe"
 ],
 "equipment_type": "Sensor (vibration / temperature)",
 "applies_to": "Machine Saver TriVibe triaxial vibration sensors on RS-485 Modbus RTU, per the 'Modbus Registers Map' page of the Machine Saver online library (revision #12).",
 "summary": "TriVibe is a triaxial vibration and temperature sensor that talks Modbus RTU on RS-485 at 115200 baud. Overall acceleration, velocity and displacement per axis are 32-bit floats, high word first. This map covers system status, run time, temperature, overall vibration values from the external and internal accelerometers, alarm states and the four configurable alarm channels.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": null,
  "baud": 115200,
  "parity": "None",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "The page states the listed registers are 0-indexed; use the number unchanged on the wire."
 },
 "default_word_order": "ABCD",
 "firmware": null,
 "source": {
  "title": "TriVibe - Modbus Registers Map (Machine Saver Knowledge Base)",
  "doc_number": "Revision #12",
  "revision_date": null,
  "url": "https://library.machinesaver.com/books/trivibe/page/modbus-registers",
  "pages": "single web page (register table)"
 },
 "notes": [
  "32-bit values are listed as a HIGH_ register followed by a LOW_ register, and the page says the sensor is big-endian, so the high word is at the lower address (ABCD).",
  "The default slave ID is the last two digits of the sensor's serial number (white label on the side).",
  "Left out: the dynamic data clip registers (49-171), DDR/capture engine controls, detonation and impact alert counters, unique ID words and sensitivity calibration registers - they are for waveform capture or factory use.",
  "TEMPERATURE (31) is divided by 10; the page does not give the unit.",
  "Units for alarm levels follow the alarm type (velocity, acceleration, displacement or temperature) chosen in ALARMn_TYPE.",
  "Alarm configuration writes need the alarm registers unlocked (SYSTEM_CONTROL = 42074) and saved afterwards (42075)."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 0,
   "documented": "0",
   "name": "SYSTEM_INFO",
   "description": "Firmware ID and revision.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1,
   "documented": "1",
   "name": "SYSTEM_CONTROL",
   "description": "Command register; use with care (some commands reset or erase).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Reset",
    "2": "Clear alarms",
    "3": "Load data",
    "42074": "Unlock alarm registers",
    "42075": "Save alarm registers",
    "45555": "Unlock config registers",
    "45556": "Save config registers",
    "55555": "Restart firmware"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 2,
   "documented": "2",
   "name": "SYSTEM_STATUS",
   "description": "Progress of the last command (done / in progress / flagged).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 3,
   "documented": "3",
   "name": "SYSTEM_STATE1",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Machine on"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4,
   "documented": "4",
   "name": "SYSTEM_STATE2",
   "description": "Internal health flags.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Power flag",
    "1": "DRAM flag",
    "2": "ADC flag",
    "3": "NVM flag",
    "4": "Temperature flag",
    "5": "Calibration flag",
    "6": "Collect flag",
    "7": "Impact flag",
    "8": "Alarm flag",
    "9": "Alarm level flag",
    "10": "Collect2 flag",
    "11": "Sine table flag",
    "12": "Detonation flag",
    "13": "Board type flag",
    "14": "On/off flag"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 5,
   "documented": "5",
   "name": "MINUTES_ON",
   "description": "Run-time counter, minutes part.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 6,
   "documented": "6",
   "name": "HOURS_ON",
   "description": "Run-time counter, hours part.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7,
   "documented": "7",
   "name": "DAYS_ON",
   "description": "Run-time counter, days part.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 17,
   "documented": "17",
   "name": "SYSTEM_RTU",
   "description": "Modbus slave ID in use.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 26,
   "documented": "26-27",
   "name": "Serial number (UIDL)",
   "description": "High word at 26, low word at 27.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 31,
   "documented": "31",
   "name": "TEMPERATURE",
   "description": "Sensor temperature; divide by 10. Unit not stated on the page.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 172,
   "documented": "172-173",
   "name": "Axis 1 acceleration",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 174,
   "documented": "174-175",
   "name": "Axis 2 acceleration",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 176,
   "documented": "176-177",
   "name": "Axis 3 acceleration",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 178,
   "documented": "178-179",
   "name": "Axis 1 velocity",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 180,
   "documented": "180-181",
   "name": "Axis 2 velocity",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 182,
   "documented": "182-183",
   "name": "Axis 3 velocity",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 184,
   "documented": "184-185",
   "name": "Axis 1 displacement",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 186,
   "documented": "186-187",
   "name": "Axis 2 displacement",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 188,
   "documented": "188-189",
   "name": "Axis 3 displacement",
   "description": "External accelerometer input, overall value.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 190,
   "documented": "190-191",
   "name": "Internal accelerometer 1 axis 1 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 192,
   "documented": "192-193",
   "name": "Internal accelerometer 1 axis 2 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 194,
   "documented": "194-195",
   "name": "Internal accelerometer 1 axis 3 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 196,
   "documented": "196-197",
   "name": "Internal accelerometer 1 axis 1 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 198,
   "documented": "198-199",
   "name": "Internal accelerometer 1 axis 2 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 200,
   "documented": "200-201",
   "name": "Internal accelerometer 1 axis 3 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 202,
   "documented": "202-203",
   "name": "Internal accelerometer 1 axis 1 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 204,
   "documented": "204-205",
   "name": "Internal accelerometer 1 axis 2 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 206,
   "documented": "206-207",
   "name": "Internal accelerometer 1 axis 3 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 208,
   "documented": "208-209",
   "name": "Internal accelerometer 2 axis 1 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 210,
   "documented": "210-211",
   "name": "Internal accelerometer 2 axis 2 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 212,
   "documented": "212-213",
   "name": "Internal accelerometer 2 axis 3 acceleration",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "g RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 214,
   "documented": "214-215",
   "name": "Internal accelerometer 2 axis 1 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 216,
   "documented": "216-217",
   "name": "Internal accelerometer 2 axis 2 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 218,
   "documented": "218-219",
   "name": "Internal accelerometer 2 axis 3 velocity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "in/s RMS",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 220,
   "documented": "220-221",
   "name": "Internal accelerometer 2 axis 1 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 222,
   "documented": "222-223",
   "name": "Internal accelerometer 2 axis 2 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 224,
   "documented": "224-225",
   "name": "Internal accelerometer 2 axis 3 displacement",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "mils",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 226,
   "documented": "226",
   "name": "ALARM_1_STATE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "Lo alarm",
    "2": "Hi alarm",
    "3": "HiHi alarm",
    "4": "Normal"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 227,
   "documented": "227",
   "name": "ALARM_2_STATE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "Lo alarm",
    "2": "Hi alarm",
    "3": "HiHi alarm",
    "4": "Normal"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 228,
   "documented": "228",
   "name": "ALARM_3_STATE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "Lo alarm",
    "2": "Hi alarm",
    "3": "HiHi alarm",
    "4": "Normal"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 229,
   "documented": "229",
   "name": "ALARM_4_STATE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No alarm",
    "1": "Lo alarm",
    "2": "Hi alarm",
    "3": "HiHi alarm",
    "4": "Normal"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 230,
   "documented": "230-231",
   "name": "Alarm 1 highest value",
   "description": "Peak value seen by this alarm channel.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 232,
   "documented": "232-233",
   "name": "Alarm 2 highest value",
   "description": "Peak value seen by this alarm channel.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 234,
   "documented": "234-235",
   "name": "Alarm 3 highest value",
   "description": "Peak value seen by this alarm channel.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 236,
   "documented": "236-237",
   "name": "Alarm 4 highest value",
   "description": "Peak value seen by this alarm channel.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 238,
   "documented": "238",
   "name": "ALARM_CONTROL",
   "description": "Set a bit to reset that alarm's highest value.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": {
    "0": "Reset alarm 1 highest",
    "1": "Reset alarm 2 highest",
    "2": "Reset alarm 3 highest",
    "3": "Reset alarm 4 highest"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 290,
   "documented": "290",
   "name": "AXIS_1_SENSOR_1_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 291,
   "documented": "291",
   "name": "AXIS_2_SENSOR_1_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 292,
   "documented": "292",
   "name": "AXIS_3_SENSOR_1_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 293,
   "documented": "293",
   "name": "AXIS_1_SENSOR_2_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 294,
   "documented": "294",
   "name": "AXIS_2_SENSOR_2_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 295,
   "documented": "295",
   "name": "AXIS_3_SENSOR_2_EXT_IMPACT_SEVERITY",
   "description": "Impact severity; raw = g peak x 10.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "units": "g peak",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 311,
   "documented": "311",
   "name": "ALARM_TRIP_DELAY",
   "description": "Delay applied to all 4 alarm channels.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 312,
   "documented": "312",
   "name": "ALARM1_AXIS",
   "description": "Which measurement this alarm watches.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Axis 1",
    "2": "Axis 2",
    "3": "Axis 3",
    "4": "T",
    "5": "IT",
    "6": "IC",
    "7": "Axis 1 D",
    "8": "Axis 2 D",
    "9": "Axis 3 D",
    "10": "Axis 1 IT",
    "11": "Axis 2 IT",
    "12": "Axis 3 IT",
    "13": "Axis 1 IC",
    "14": "Axis 2 IC",
    "15": "Axis 3 IC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 313,
   "documented": "313",
   "name": "ALARM1_TYPE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Velocity",
    "2": "Acceleration",
    "3": "Displacement",
    "4": "Temperature",
    "5": "Alert",
    "6": "Danger",
    "7": "Detonation"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 314,
   "documented": "314-315",
   "name": "Alarm 1 Lo level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 316,
   "documented": "316-317",
   "name": "Alarm 1 Hi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 318,
   "documented": "318-319",
   "name": "Alarm 1 HiHi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 320,
   "documented": "320-321",
   "name": "Alarm 1 hysteresis",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 322,
   "documented": "322",
   "name": "ALARM2_AXIS",
   "description": "Which measurement this alarm watches.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Axis 1",
    "2": "Axis 2",
    "3": "Axis 3",
    "4": "T",
    "5": "IT",
    "6": "IC",
    "7": "Axis 1 D",
    "8": "Axis 2 D",
    "9": "Axis 3 D",
    "10": "Axis 1 IT",
    "11": "Axis 2 IT",
    "12": "Axis 3 IT",
    "13": "Axis 1 IC",
    "14": "Axis 2 IC",
    "15": "Axis 3 IC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 323,
   "documented": "323",
   "name": "ALARM2_TYPE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Velocity",
    "2": "Acceleration",
    "3": "Displacement",
    "4": "Temperature",
    "5": "Alert",
    "6": "Danger",
    "7": "Detonation"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 324,
   "documented": "324-325",
   "name": "Alarm 2 Lo level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 326,
   "documented": "326-327",
   "name": "Alarm 2 Hi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 328,
   "documented": "328-329",
   "name": "Alarm 2 HiHi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 330,
   "documented": "330-331",
   "name": "Alarm 2 hysteresis",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 332,
   "documented": "332",
   "name": "ALARM3_AXIS",
   "description": "Which measurement this alarm watches.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Axis 1",
    "2": "Axis 2",
    "3": "Axis 3",
    "4": "T",
    "5": "IT",
    "6": "IC",
    "7": "Axis 1 D",
    "8": "Axis 2 D",
    "9": "Axis 3 D",
    "10": "Axis 1 IT",
    "11": "Axis 2 IT",
    "12": "Axis 3 IT",
    "13": "Axis 1 IC",
    "14": "Axis 2 IC",
    "15": "Axis 3 IC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 333,
   "documented": "333",
   "name": "ALARM3_TYPE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Velocity",
    "2": "Acceleration",
    "3": "Displacement",
    "4": "Temperature",
    "5": "Alert",
    "6": "Danger",
    "7": "Detonation"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 334,
   "documented": "334-335",
   "name": "Alarm 3 Lo level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 336,
   "documented": "336-337",
   "name": "Alarm 3 Hi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 338,
   "documented": "338-339",
   "name": "Alarm 3 HiHi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 340,
   "documented": "340-341",
   "name": "Alarm 3 hysteresis",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 342,
   "documented": "342",
   "name": "ALARM4_AXIS",
   "description": "Which measurement this alarm watches.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Axis 1",
    "2": "Axis 2",
    "3": "Axis 3",
    "4": "T",
    "5": "IT",
    "6": "IC",
    "7": "Axis 1 D",
    "8": "Axis 2 D",
    "9": "Axis 3 D",
    "10": "Axis 1 IT",
    "11": "Axis 2 IT",
    "12": "Axis 3 IT",
    "13": "Axis 1 IC",
    "14": "Axis 2 IC",
    "15": "Axis 3 IC"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 343,
   "documented": "343",
   "name": "ALARM4_TYPE",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Idle",
    "1": "Velocity",
    "2": "Acceleration",
    "3": "Displacement",
    "4": "Temperature",
    "5": "Alert",
    "6": "Danger",
    "7": "Detonation"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 344,
   "documented": "344-345",
   "name": "Alarm 4 Lo level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 346,
   "documented": "346-347",
   "name": "Alarm 4 Hi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 348,
   "documented": "348-349",
   "name": "Alarm 4 HiHi level",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 350,
   "documented": "350-351",
   "name": "Alarm 4 hysteresis",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Poll at 115200 8N1 using the slave ID from the serial number label. Read FC03 block 172-189 for overall vibration and 226-229 for alarm states; write with FC16 only.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 178,
    "why": "Axis 1 velocity"
   },
   {
    "table": "holding_register",
    "address": 180,
    "why": "Axis 2 velocity"
   },
   {
    "table": "holding_register",
    "address": 182,
    "why": "Axis 3 velocity"
   },
   {
    "table": "holding_register",
    "address": 172,
    "why": "Axis 1 acceleration"
   },
   {
    "table": "holding_register",
    "address": 31,
    "why": "Temperature"
   },
   {
    "table": "holding_register",
    "address": 226,
    "why": "Alarm 1 state"
   },
   {
    "table": "holding_register",
    "address": 4,
    "why": "System state flags"
   }
  ],
  "enable": "Modbus RTU is always on. Configuration and alarm registers are locked until the matching unlock command is written to SYSTEM_CONTROL (register 1), and must be saved with the matching save command.",
  "watchdog": null,
  "quirks": [
   "Only FC03 and FC16 are supported; write single registers with FC16 and a length of 1.",
   "Floats are high word first (ABCD).",
   "Default slave ID is not 1: it is the last two digits of the serial number."
  ],
  "setup": [
   "Serial: 115200 baud, no parity, 8 data bits, 1 stop bit, no handshake.",
   "Each sensor on a multi-drop bus needs a unique slave ID."
  ],
  "gotchas": [
   "Writing the wrong SYSTEM_CONTROL value can reset the sensor or erase its EEPROM."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/machine-saver/trivibe",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}