 "manufacturer": "Morningstar",
 "manufacturer_slug": "morningstar",
 "model": "SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)",
 "model_slug": "sunsaver-duo",
 "short_model": "SunSaver Duo",
 "aliases": [
  "SunSaver Duo",
  "SSDuo"
 ],
 "equipment_type": "Solar charge controller (PWM, dual battery)",
 "applies_to": "Morningstar SunSaver Duo through the MSC MeterBus-to-RS-232 adapter; Modbus specification V04 (19 March 2019). 16-bit registers only.",
 "summary": "The SunSaver Duo is a PWM solar charge controller that charges two separate batteries. Via its RJ-11 MeterBus port and Morningstar's MSC adapter it speaks Modbus RTU: both battery voltages and charge currents, solar voltage, duty cycles, charge setpoints in use, state and fault bits, plus EEPROM custom settings and a few coils.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 9600,
  "parity": "None",
  "data_bits": 8,
  "stop_bits": 2,
  "tcp_port": null
 },
 "addressing": {
  "convention": "hex 0-based",
  "note": "The hex PDU address in Morningstar's table is the wire address; the spec says all listed addresses are request-PDU addresses, and its example reads battery 1 voltage at 0x0000 (0x5CD0 = 23760 / 1800 = 13.20 V)."
 },
 "default_word_order": null,
 "firmware": null,
 "source": {
  "title": "SunSaver Duo MODBUS Specification",
  "doc_number": "V04",
  "revision_date": "2019-03-19",
  "url": "https://www.morningstarcorp.com/wp-content/uploads/technical-doc-sunsaver-duo-modbus-specification-en.pdf",
  "pages": "p. 3 (parameters), pp. 4-7 (RAM, EEPROM, coils, bit tables), pp. 8-15 (definitions), p. 16 (examples)"
 },
 "notes": [
  "Left out: the 32-bit hourmeter and amp-hour counters (0x0013-0x001A). The register table puts the HI word first, but the spec's own two-word example reads the hourmeter LO word at 0x0013 and HI at 0x0014, and the revision history says the HI/LO addresses were swapped in an earlier version. The word order cannot be settled from the document.",
  "Left out: the 'reset amp-hours' coil, because the table gives 0x0010 and the definitions page gives 0x0017 (which is also the min/max reset coil).",
  "Scaling formulas (n / 1800 for battery voltages, n / 1032 for solar voltage, n / 673 for currents, 0-417 = 0-100 % for duty/priority) are converted to multipliers.",
  "Left out: the pre-scaled temperatures at 0x0100-0x0105 (F and C copies), because the spec gives no data type or signedness for them and sub-zero readings are expected.",
  "Only the 'DIP off' custom voltages are listed for each battery; the 'DIP on' set (0xE00C-0xE011, 0xE018-0xE01D) follows the same layout. The two ID registers 0xE000/0xE001 are not listed because the table and the definitions disagree on which range belongs to which ID.",
  "Battery detect registers follow the register table (0x010F, 0x0110); the definitions page repeats the battery-state addresses for them, which looks like a copy error.",
  "Any EEPROM write (FC 0x06) sets an 'EEPROM changed' fault that needs a controller reset."
 ],
 "integration": {
  "summary": "Through the MSC adapter at 9600 8N2, ID 1, read 0x0000-0x0010 for both battery voltages, solar voltage and charge currents, and 0x0108-0x0110 for state, faults and battery states.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 0,
    "why": "Battery 1 voltage"
   },
   {
    "table": "holding_register",
    "address": 1,
    "why": "Battery 2 voltage"
   },
   {
    "table": "holding_register",
    "address": 3,
    "why": "Charge current battery 1"
   },
   {
    "table": "holding_register",
    "address": 4,
    "why": "Charge current battery 2"
   },
   {
    "table": "holding_register",
    "address": 264,
    "why": "Controller state"
   },
   {
    "table": "holding_register",
    "address": 265,
    "why": "Fault bitfield"
   }
  ],
  "enable": "The meter port auto-detects Meterbus or Modbus; connect the MSC adapter and poll. Coil 0x00F1 switches the port back to Meterbus for a remote meter.",
  "watchdog": null,
  "quirks": [
   "Both FC 0x03 and FC 0x04 are supported for reading.",
   "EEPROM values that need updating are saved once every 24 hours; coil 0x0016 forces it."
  ],
  "setup": [
   "Serial: 9600 baud, 8 data bits, no parity, 2 stop bits, no flow control."
  ],
  "gotchas": [
   "The RJ-11 port is MeterBus, not RS-485; Morningstar's MSC adapter is needed."
  ]
 },
 "registers": [
  {
   "table": "coil",
   "address": 20,
   "documented": "0x0014",
   "name": "Clear faults",
   "description": "Some faults need 30 s before they can be cleared.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 22,
   "documented": "0x0016",
   "name": "Force EEPROM update",
   "description": "Writes RAM values to EEPROM.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 23,
   "documented": "0x0017",
   "name": "Reset min/max volts and amps",
   "description": "Set only; reads 0.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 241,
   "documented": "0x00F1",
   "name": "Switch to Meterbus protocol",
   "description": "Hands the port back to the Morningstar remote meter protocol.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 255,
   "documented": "0x00FF",
   "name": "Reset controller",
   "description": "Reboots the controller software.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 0,
   "documented": "0x0000",
   "name": "vb1 - battery 1 voltage",
   "description": "Filtered (about 2.5 s).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1,
   "documented": "0x0001",
   "name": "vb2 - battery 2 voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 2,
   "documented": "0x0002",
   "name": "va - solar voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0009689922480620155,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 3,
   "documented": "0x0003",
   "name": "ia1 - charge current battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0014858841010401188,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4,
   "documented": "0x0004",
   "name": "ia2 - charge current battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0014858841010401188,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 8,
   "documented": "0x0008",
   "name": "vref1 - charge reference battery 1",
   "description": "Temperature-compensated target voltage.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 9,
   "documented": "0x0009",
   "name": "vref2 - charge reference battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 10,
   "documented": "0x000A",
   "name": "dutcyc1 - PWM duty battery 1",
   "description": "0-417 = 0-100 %.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.23980815347721823,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 11,
   "documented": "0x000B",
   "name": "dutcyc2 - PWM duty battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.23980815347721823,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 12,
   "documented": "0x000C",
   "name": "vmaxb1 - max battery 1 voltage",
   "description": "Since last min/max clear.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 13,
   "documented": "0x000D",
   "name": "vminb1 - min battery 1 voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 14,
   "documented": "0x000E",
   "name": "vmaxb2 - max battery 2 voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 15,
   "documented": "0x000F",
   "name": "vminb2 - min battery 2 voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16,
   "documented": "0x0010",
   "name": "iamax - max solar current",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0014858841010401188,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 27,
   "documented": "0x001B",
   "name": "tcompcoef - temperature compensation in use",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 28,
   "documented": "0x001C",
   "name": "priority - battery 1 charge priority",
   "description": "Share of charge current to battery 1 (0-417 = 0-100 %).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.23980815347721823,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 29,
   "documented": "0x001D",
   "name": "vabs1 - absorption voltage battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 30,
   "documented": "0x001E",
   "name": "veql1 - equalize voltage battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 31,
   "documented": "0x001F",
   "name": "vfloat1 - float voltage battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32,
   "documented": "0x0020",
   "name": "vclamp1 - max regulation voltage battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 33,
   "documented": "0x0021",
   "name": "tfloat1 - float timer battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34,
   "documented": "0x0022",
   "name": "teq1 - equalize timer battery 1",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 35,
   "documented": "0x0023",
   "name": "vabs2 - absorption voltage battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 36,
   "documented": "0x0024",
   "name": "veql2 - equalize voltage battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 37,
   "documented": "0x0025",
   "name": "vfloat2 - float voltage battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 38,
   "documented": "0x0026",
   "name": "vclamp2 - max regulation voltage battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 39,
   "documented": "0x0027",
   "name": "tfloat2 - float timer battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40,
   "documented": "0x0028",
   "name": "teq2 - equalize timer battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "min",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 262,
   "documented": "0x0106",
   "name": "dc1 - duty cycle battery 1",
   "description": "Pre-scaled percent.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 263,
   "documented": "0x0107",
   "name": "dc2 - duty cycle battery 2",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "%",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 264,
   "documented": "0x0108",
   "name": "state - controller state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "NORMAL",
    "3": "NIGHT",
    "4": "FAULT"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 265,
   "documented": "0x0109",
   "name": "faults - fault bitfield",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Reverse polarity solar",
    "1": "Reverse polarity battery 1",
    "2": "Reverse polarity battery 2",
    "3": "Damaged local temperature sensor",
    "4": "Damaged or removed RTS",
    "5": "Over-current",
    "6": "High temperature disconnect",
    "7": "High voltage disconnect"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 266,
   "documented": "0x010A",
   "name": "flags - controller flags",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "3": "Regulation",
    "4": "Valid RTS",
    "5": "Alternating",
    "6": "On/off regulation",
    "7": "Started"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 267,
   "documented": "0x010B",
   "name": "DIP switch positions",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "DIP 1",
    "1": "DIP 2",
    "2": "DIP 3",
    "3": "DIP 4",
    "4": "DIP 5"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 269,
   "documented": "0x010D",
   "name": "b1_state - battery 1 charge state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "NORMAL",
    "1": "EQUALIZE",
    "2": "FLOAT"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 270,
   "documented": "0x010E",
   "name": "b2_state - battery 2 charge state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "NORMAL",
    "1": "EQUALIZE",
    "2": "FLOAT"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 271,
   "documented": "0x010F",
   "name": "b1_detect - battery 1 detected",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Disconnected",
    "1": "Connected"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 272,
   "documented": "0x0110",
   "name": "b2_detect - battery 2 detected",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Disconnected",
    "1": "Connected"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57346,
   "documented": "0xE002",
   "name": "priority_off - battery 1 priority, DIP 3 off",
   "description": "EEPROM custom setting (0-417).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.23980815347721823,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57347,
   "documented": "0xE003",
   "name": "priority_on - battery 1 priority, DIP 3 on",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.23980815347721823,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57348,
   "documented": "0xE004",
   "name": "tcompcoef - temperature compensation (EEPROM)",
   "description": "Per 12 V battery per °C; typical 0.030.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57350,
   "documented": "0xE006",
   "name": "Battery 1 (DIP 1 off) absorption voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57351,
   "documented": "0xE007",
   "name": "Battery 1 (DIP 1 off) equalize voltage",
   "description": "0 disables equalize.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57352,
   "documented": "0xE008",
   "name": "Battery 1 (DIP 1 off) float voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57362,
   "documented": "0xE012",
   "name": "Battery 2 (DIP 2 off) absorption voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57363,
   "documented": "0xE013",
   "name": "Battery 2 (DIP 2 off) equalize voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57364,
   "documented": "0xE014",
   "name": "Battery 2 (DIP 2 off) float voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0005555555555555556,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "page": "https://easymodbus.com/modbus-register-maps/morningstar/sunsaver-duo",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}