 "manufacturer": "Morningstar",
 "manufacturer_slug": "morningstar",
 "model": "SunSaver MPPT solar charge controller (Modbus RTU via MeterBus)",
 "model_slug": "sunsaver-mppt",
 "short_model": "SunSaver MPPT",
 "aliases": [
  "SunSaver MPPT",
  "SS-MPPT"
 ],
 "equipment_type": "Solar charge controller (MPPT, battery charger)",
 "applies_to": "Morningstar SunSaver MPPT through the MSC MeterBus-to-RS-232 adapter; Modbus specification v11.",
 "summary": "The SunSaver MPPT is a Morningstar MPPT solar charge controller with a load output. It speaks Modbus RTU on its RJ-11 meter port through Morningstar's MSC adapter (MeterBus to RS-232). RAM registers give battery, array and load readings, charge and load state and fault bitfields; EEPROM registers hold the charge setpoints and LO-first copies of the Ah and hour counters; coils force load/charge disconnect and clear counters.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 9600,
  "parity": "None",
  "data_bits": 8,
  "stop_bits": 2,
  "tcp_port": null
 },
 "addressing": {
  "convention": "hex 0-based",
  "note": "Morningstar prints a PDU address (hex, goes on the wire as-is) and a logical address (PDU + 1). The manual states all listed addresses are request-PDU addresses; its scaling example reads battery voltage at 0x0008."
 },
 "default_word_order": "CDAB",
 "firmware": "Va_ref_fixed registers need firmware v08 or later.",
 "source": {
  "title": "SunSaver MPPT MODBUS Specification",
  "doc_number": "v11",
  "revision_date": "2017-04-03",
  "url": "https://www.morningstarcorp.com/wp-content/uploads/technical-doc-sunsaver-mppt-modbus-specification-en.pdf",
  "pages": "p. 3 (parameters), pp. 3-7 (RAM, EEPROM, coils), pp. 11-17 (definitions and enums), p. 27 (examples)"
 },
 "notes": [
  "Scaling: Morningstar gives formulas such as n x 100 x 2^-15; these are converted to a single multiplier (e.g. 100/32768 = 0.0030517578125 for voltages, 79.16/32768 for currents, 989.5/65536 for power, 96.667/32768 for Vb_ref). The manual's example: 0x0F96 = 3990 x 100 / 32768 = 12.18 V.",
  "Word order: the RAM table names each 32-bit pair HI word then LO word (e.g. hourmeter_HI 0x0021, hourmeter_LO 0x0022), but the spec's own two-word example reads the hourmeter LO word at the lower address. Because the document contradicts itself, the RAM 32-bit values (Ah counters 0x0015-0x0020, hourmeter 0x0021, alarm 0x0023 and daily alarm 0x0031) are left out. The EEPROM read-only copies are printed LO word first (Ehourmeter_LO 0xE040, Ehourmeter_HI 0xE041), which matches the example, so those are listed as CDAB.",
  "The two-word example uses addresses 0x0025/0x0026 for the hourmeter, which do not match the table (0x0021/0x0022).",
  "Both Read Holding (0x03) and Read Input (0x04) are supported; registers are listed as holding registers. EEPROM is written with Write Single Register (0x06) only.",
  "Alarm bitfield bits (32-bit value at 0x0023, not listed): 0 RTS open, 1 RTS shorted, 2 RTS disconnected, 3 Ths open, 4 Ths shorted, 5 SSMPPT hot, 6 current limit, 7 current offset, 10 uncalibrated, 11 RTS miswire, 14 miswire, 15 FET open, 16 P12, 17 high Va current limit.",
  "Not listed: bank-2 charge settings (0xE00D-0xE017), LED thresholds, the data logger (0x8000-0x81FF) and the remaining EEPROM timers.",
  "Voltages and currents are listed as unsigned raw values; temperatures are signed (-128 to +127)."
 ],
 "integration": {
  "summary": "Connect through the Morningstar MSC adapter at 9600 8N2, ID 1. Read 0x0008-0x0014 for live data; multiply raw voltages by 100/32768 and currents by 79.16/32768. Use coils 0x0001/0x0002 to switch the load or charger off remotely.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 8,
    "why": "Battery voltage"
   },
   {
    "table": "holding_register",
    "address": 9,
    "why": "Array voltage"
   },
   {
    "table": "holding_register",
    "address": 11,
    "why": "Charging current"
   },
   {
    "table": "holding_register",
    "address": 17,
    "why": "Charge state"
   },
   {
    "table": "holding_register",
    "address": 18,
    "why": "Array faults"
   },
   {
    "table": "holding_register",
    "address": 39,
    "why": "Charge output power"
   },
   {
    "table": "coil",
    "address": 1,
    "why": "Remote load disconnect"
   }
  ],
  "enable": "Set the comm DIP switch (switch 4, reported as bit 3 of register 0x0025) to MODBUS protocol instead of Meterbus, and connect via the MSC RS-232 adapter.",
  "watchdog": null,
  "quirks": [
   "Every analog value needs its own formula-derived multiplier; there are no floats.",
   "Any EEPROM write sets an 'EEPROM changed' fault; reset the controller (coil 0x00FF) to clear it. Writes are not verified."
  ],
  "setup": [
   "Serial: 9600 baud, 8 data bits, no parity, 2 stop bits, no flow control.",
   "Modbus ID is stored in EEPROM at 0xE034 (1-247)."
  ],
  "gotchas": [
   "The MeterBus port is not RS-485; a Morningstar adapter is required."
  ]
 },
 "registers": [
  {
   "table": "coil",
   "address": 0,
   "documented": "0x0000",
   "name": "Equalize triggered",
   "description": "",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 1,
   "documented": "0x0001",
   "name": "Load disconnect",
   "description": "1 forces the load output off.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 2,
   "documented": "0x0002",
   "name": "Charge disconnect",
   "description": "1 forces the charger off.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 16,
   "documented": "0x0010",
   "name": "Clear Ah resettable",
   "description": "Set only; reads 0.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 17,
   "documented": "0x0011",
   "name": "Clear Ah total",
   "description": "Set only; reads 0.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 18,
   "documented": "0x0012",
   "name": "Clear kWh",
   "description": "Set only; reads 0.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 22,
   "documented": "0x0016",
   "name": "Force EEPROM update",
   "description": "Set only; reads 0.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "coil",
   "address": 255,
   "documented": "0x00FF",
   "name": "Reset control",
   "description": "Restarts the controller (needed after EEPROM writes).",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 8,
   "documented": "0x0008",
   "name": "Adc_vb_f - battery voltage",
   "description": "Filtered (about 1 s).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 9,
   "documented": "0x0009",
   "name": "Adc_va_f - array voltage",
   "description": "Solar input terminal voltage.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 10,
   "documented": "0x000A",
   "name": "Adc_vl_f - load voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 11,
   "documented": "0x000B",
   "name": "Adc_ic_f - charging current",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.002415771484375,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 12,
   "documented": "0x000C",
   "name": "Adc_il_f - load current",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.002415771484375,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 13,
   "documented": "0x000D",
   "name": "T_hs - heatsink temperature",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 14,
   "documented": "0x000E",
   "name": "T_batt - battery temperature",
   "description": "Ambient sensor, or RTS if connected.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 15,
   "documented": "0x000F",
   "name": "T_amb - ambient temperature",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16,
   "documented": "0x0010",
   "name": "T_rts - remote temperature sensor",
   "description": "0x80 if no RTS is connected.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 17,
   "documented": "0x0011",
   "name": "Charge state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "START",
    "1": "NIGHT_CHECK",
    "2": "DISCONNECT",
    "3": "NIGHT",
    "4": "FAULT",
    "5": "BULK_CHARGE",
    "6": "ABSORPTION",
    "7": "FLOAT",
    "8": "EQUALIZE"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 18,
   "documented": "0x0012",
   "name": "Array fault bitfield",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Overcurrent",
    "1": "FETs shorted",
    "2": "Software bug",
    "3": "Battery HVD",
    "4": "Array HVD",
    "5": "EEPROM setting edit (reset required)",
    "6": "RTS shorted",
    "7": "RTS was valid, now disconnected",
    "8": "Local temperature sensor failed"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 19,
   "documented": "0x0013",
   "name": "Vb_f - battery voltage, slow filter",
   "description": "About 25 s filter.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20,
   "documented": "0x0014",
   "name": "Vb_ref - charge target voltage",
   "description": "Temperature-compensated regulation reference.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.002950042724609375,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 25,
   "documented": "0x0019",
   "name": "kWh charge",
   "description": "The spec marks it as possibly resettable.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 26,
   "documented": "0x001A",
   "name": "Load state",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "START",
    "1": "LOAD_ON",
    "2": "LVD_WARNING",
    "3": "LVD",
    "4": "FAULT",
    "5": "DISCONNECT"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 27,
   "documented": "0x001B",
   "name": "Load fault bitfield",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "External short circuit",
    "1": "Overcurrent",
    "2": "FETs shorted",
    "3": "Software bug",
    "4": "HVD",
    "5": "Heatsink over-temperature",
    "6": "EEPROM setting edit (reset required)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 28,
   "documented": "0x001C",
   "name": "V_lvd - LVD voltage",
   "description": "Current-compensated low voltage disconnect point.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 37,
   "documented": "0x0025",
   "name": "DIP switch settings",
   "description": "",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Custom battery settings",
    "1": "Custom load settings",
    "2": "Equalize enabled",
    "3": "MODBUS protocol selected (else Meterbus)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 38,
   "documented": "0x0026",
   "name": "LED state",
   "description": "SOC LED pattern code (0-19).",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 39,
   "documented": "0x0027",
   "name": "Power_out - charge output power",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01509857177734375,
   "scale_factor_ref": null,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 40,
   "documented": "0x0028",
   "name": "Sweep_Vmp - array Vmp",
   "description": "Found during last MPPT sweep.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 41,
   "documented": "0x0029",
   "name": "Sweep_Pmax - array max power",
   "description": "Found during last sweep.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.01509857177734375,
   "scale_factor_ref": null,
   "units": "W",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42,
   "documented": "0x002A",
   "name": "Sweep_Voc - array Voc",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 43,
   "documented": "0x002B",
   "name": "Vb_min_daily",
   "description": "Today's minimum battery voltage.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 44,
   "documented": "0x002C",
   "name": "Vb_max_daily",
   "description": "Today's maximum battery voltage.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 45,
   "documented": "0x002D",
   "name": "Ahc_daily",
   "description": "Charge Ah today.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 46,
   "documented": "0x002E",
   "name": "Ahl_daily",
   "description": "Load Ah today.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 47,
   "documented": "0x002F",
   "name": "Array fault bitfield, daily",
   "description": "Sticky for the day.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Overcurrent",
    "1": "FETs shorted",
    "2": "Software bug",
    "3": "Battery HVD",
    "4": "Array HVD",
    "5": "EEPROM setting edit (reset required)",
    "6": "RTS shorted",
    "7": "RTS was valid, now disconnected",
    "8": "Local temperature sensor failed"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 48,
   "documented": "0x0030",
   "name": "Load fault bitfield, daily",
   "description": "Sticky for the day.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "External short circuit",
    "1": "Overcurrent",
    "2": "FETs shorted",
    "3": "Software bug",
    "4": "HVD",
    "5": "Heatsink over-temperature",
    "6": "EEPROM setting edit (reset required)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 51,
   "documented": "0x0033",
   "name": "Vb_min - minimum battery voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 52,
   "documented": "0x0034",
   "name": "Vb_max - maximum battery voltage",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57,
   "documented": "0x0039",
   "name": "Va_ref_fixed - fixed array voltage",
   "description": "Non-zero stops MPPT and holds this array voltage. FW v08+.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 58,
   "documented": "0x003A",
   "name": "Va_ref_fixed_pct - array voltage % of Voc",
   "description": "Non-zero holds array at this % of Voc. FW v08+.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.390625,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57344,
   "documented": "0xE000",
   "name": "EV_reg - regulation voltage @25°C",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57345,
   "documented": "0xE001",
   "name": "EV_float - float voltage @25°C",
   "description": "0 disables float.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57346,
   "documented": "0xE002",
   "name": "Et_float - absorption time before float",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57351,
   "documented": "0xE007",
   "name": "EV_eq - equalize voltage @25°C",
   "description": "0 disables equalize.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57352,
   "documented": "0xE008",
   "name": "Et_eqcalendar - days between equalize",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "days",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57371,
   "documented": "0xE01B",
   "name": "EV_hvd - high voltage disconnect",
   "description": "0 disables HVD.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57372,
   "documented": "0xE01C",
   "name": "EV_hvr - high voltage reconnect",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57378,
   "documented": "0xE022",
   "name": "EV_lvd - load low voltage disconnect",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57379,
   "documented": "0xE023",
   "name": "EV_lvr - load low voltage reconnect",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.0030517578125,
   "scale_factor_ref": null,
   "units": "V",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57396,
   "documented": "0xE034",
   "name": "Emodbus_id - Modbus ID",
   "description": "1-247.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57400,
   "documented": "0xE038",
   "name": "Eic_lim - charge current limit",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.002415771484375,
   "scale_factor_ref": null,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57408,
   "documented": "0xE040",
   "name": "Ehourmeter (EEPROM copy)",
   "description": "LO word at 0xE040, HI word at 0xE041.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "scale_factor_ref": null,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57414,
   "documented": "0xE046",
   "name": "EAhc_r - Ah charge resettable (EEPROM)",
   "description": "LO word first.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57416,
   "documented": "0xE048",
   "name": "EAhc_t - Ah charge total (EEPROM)",
   "description": "LO word first.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 57418,
   "documented": "0xE04A",
   "name": "EkWhc - kWh charge (EEPROM)",
   "description": "The spec marks it as possibly resettable.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 0.1,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "page": "https://easymodbus.com/modbus-register-maps/morningstar/sunsaver-mppt",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",