 "manufacturer": "Sontex",
 "manufacturer_slug": "sontex",
 "model": "Supercal 531 / Superstatic 440 / 449 with Modbus EIA-485 module",
 "model_slug": "supercal-531-modbus-module",
 "short_model": "Supercal 531 Modbus",
 "aliases": [
  "Supercal 531",
  "Superstatic 440",
  "Superstatic 449",
  "Sontex Modbus EIA-485 module",
  "0531P217"
 ],
 "equipment_type": "Energy meter (heat / cooling meter)",
 "applies_to": "Sontex Modbus EIA-485 plug-in module in a Supercal 531 integrator or Superstatic 440/449 heat meter, integrator firmware 3.7 or later; user manual V05 (2019-09).",
 "summary": "Sontex's Supercal 531 integrator and the Superstatic 440/449 heat and cooling meters take an optional RS-485 plug-in module that makes them a Modbus RTU or ASCII slave. Settings and the clock are holding registers, meter values are input registers and error flags are discrete inputs. This map covers the settings block, device information, error flags and the IEEE-754 float copies of energy, volume, pulse inputs, power, flow and temperatures, including the Set-Day stored values.",
 "transport": [
  "RTU",
  "ASCII"
 ],
 "defaults": {
  "unit_id": 1,
  "baud": 19200,
  "parity": "Even",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "Modicon",
  "note": "The manual says register numbering starts at 1, which is physical address 0 in the telegram, and prints Modicon-style references: 40011 is holding wire address 10, 30103 is input wire address 102, 10001 is discrete input 0. Its own Modbus Poll / ModScan screenshots use the same 30713/30103 references."
 },
 "default_word_order": "CDAB",
 "firmware": "Integrator / meter firmware FW 3.7 or higher",
 "source": {
  "title": "Modbus EIA-485 Module for Supercal 531 and Superstatic 440/449 - Instructions for Use",
  "doc_number": "0531P217 V05",
  "revision_date": "2019-09",
  "url": "https://www.neovac.ch/downloadcenter/document-a9b1ddfb-1182-446f-b1b9-132bdb729345.pdf",
  "unofficial": true,
  "pages": "p. 10 (word swapping example), pp. 12-17 (defaults, changing settings), pp. 30-39 (register tables), pp. 40-45 (read-out examples)"
 },
 "notes": [
  "This is an unaltered Sontex manual hosted by the Swiss distributor NeoVac; Sontex keeps its own copy behind a login-only extranet and does not host it publicly.",
  "Word order: the tables label 32-bit values '(h-l)' but every table footer says Sontex uses l-h ordering, and the word-swapping example (p. 10) puts the low word in the first register (30723) and the high word in the next (30724). The ModScan example also uses 'least significant register first'. All 32-bit values here are therefore CDAB.",
  "Units of the float values follow the unit-code register at the start of each block (e.g. 30101 energy: 18 Wh, 19 kWh, 146 MWh, 126 MJ, 226 GJ, 20 BTU).",
  "Left out: the 'long data point' integer copies (30201-30220, 30401-30420, 30601-30618, 30801-30834). Their value must be divided by 10 to the power of a separate Decimals register (0-3), which cannot be expressed as a fixed scale. The float copies carry the same quantities.",
  "Left out: monthly logs 31001-33266 (32 stored months per quantity, 2 registers each, floats from 31003 and longs from 31203), which are long arrays rather than single points.",
  "40020 Flow control is printed as 'MB_RTU=0, MB_RTU=1' (presumably RTU/ASCII, but the source does not say), so no enum is given. 32-bit integers are given as UINT32 because the source does not mark them signed (it marks signed values explicitly elsewhere).",
  "The same document also covers the BACnet MS/TP module; that part is not used here."
 ],
 "registers": [
  {
   "table": "discrete_input",
   "address": 0,
   "documented": "10001",
   "name": "Error status: temp. sensor 1",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 1,
   "documented": "10002",
   "name": "Error status: temp. sensor 2",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 2,
   "documented": "10003",
   "name": "Error status: flow",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 3,
   "documented": "10004",
   "name": "Error status: MET access",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 4,
   "documented": "10005",
   "name": "Error status: MIO access",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 5,
   "documented": "10006",
   "name": "Error status: EEPROM blank / invalid",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 6,
   "documented": "10007",
   "name": "Error status: AD converter",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 7,
   "documented": "10008",
   "name": "Error status: hardware",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 8,
   "documented": "10009",
   "name": "Error status: supply power",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 9,
   "documented": "10010",
   "name": "Error status: option 1",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 10,
   "documented": "10011",
   "name": "Error status: option 2",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 11,
   "documented": "10012",
   "name": "Error status: A1",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 12,
   "documented": "10013",
   "name": "Error status: A2",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 13,
   "documented": "10014",
   "name": "Error status: internal HW",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 14,
   "documented": "10015",
   "name": "Error status: CRC error",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "discrete_input",
   "address": 15,
   "documented": "10016",
   "name": "Error status: configuration error",
   "description": "1 = error active.",
   "data_type": "BIT",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 0,
   "documented": "30001 - 30002",
   "name": "Fabrication number MET",
   "description": "Meter serial number.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 2,
   "documented": "30003",
   "name": "Firmware version",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 3,
   "documented": "30004 - 30005",
   "name": "Baud rate",
   "description": "",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 5,
   "documented": "30006 - 30007",
   "name": "Running hours",
   "description": "",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 7,
   "documented": "30008",
   "name": "Last Set-Day 1: month",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 8,
   "documented": "30009",
   "name": "Last Set-Day 1: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 9,
   "documented": "30010",
   "name": "Last Set-Day 2: month",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 10,
   "documented": "30011",
   "name": "Last Set-Day 2: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 11,
   "documented": "30012",
   "name": "Last monthly data: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 100,
   "documented": "30101",
   "name": "Energy unit (float block)",
   "description": "Unit code for the energy floats.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "18": "Wh",
    "19": "kWh",
    "146": "MWh",
    "126": "MJ",
    "226": "GJ",
    "20": "BTU"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 102,
   "documented": "30103 - 30104",
   "name": "Energy totalizer heating",
   "description": "Unit per 30101.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 104,
   "documented": "30105 - 30106",
   "name": "Energy totalizer tariff 1",
   "description": "Unit per 30101.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 106,
   "documented": "30107 - 30108",
   "name": "Energy totalizer tariff 2",
   "description": "Unit per 30101.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 108,
   "documented": "30109 - 30110",
   "name": "Energy stored ST1",
   "description": "Energy at Set-Day 1; unit per 30101.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 110,
   "documented": "30111 - 30112",
   "name": "Energy tariff 1 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 112,
   "documented": "30113 - 30114",
   "name": "Energy tariff 2 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 114,
   "documented": "30115 - 30116",
   "name": "Energy stored ST2",
   "description": "Energy at Set-Day 2; unit per 30101.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 116,
   "documented": "30117 - 30118",
   "name": "Energy tariff 1 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 118,
   "documented": "30119 - 30120",
   "name": "Energy tariff 2 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 300,
   "documented": "30301",
   "name": "Volume unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "80": "m3",
    "83": "US gallon"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 302,
   "documented": "30303 - 30304",
   "name": "Volume",
   "description": "Unit per 30301.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 304,
   "documented": "30305 - 30306",
   "name": "Volume tariff 1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 306,
   "documented": "30307 - 30308",
   "name": "Volume tariff 2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 308,
   "documented": "30309 - 30310",
   "name": "Volume stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 310,
   "documented": "30311 - 30312",
   "name": "Volume tariff 1 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 312,
   "documented": "30313 - 30314",
   "name": "Volume tariff 2 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 314,
   "documented": "30315 - 30316",
   "name": "Volume stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 316,
   "documented": "30317 - 30318",
   "name": "Volume tariff 1 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 318,
   "documented": "30319 - 30320",
   "name": "Volume tariff 2 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 500,
   "documented": "30501",
   "name": "Auxiliary A1 unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No unit",
    "18": "Wh",
    "19": "kWh",
    "146": "MWh",
    "126": "MJ",
    "226": "GJ",
    "20": "BTU",
    "80": "m3",
    "83": "US gallon"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 502,
   "documented": "30503 - 30504",
   "name": "Auxiliary A1",
   "description": "Pulse input A1 counter; unit per 30501.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 504,
   "documented": "30505 - 30506",
   "name": "Auxiliary A1 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 506,
   "documented": "30507 - 30508",
   "name": "Auxiliary A1 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 510,
   "documented": "30511",
   "name": "Auxiliary A2 unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "No unit",
    "18": "Wh",
    "19": "kWh",
    "146": "MWh",
    "126": "MJ",
    "226": "GJ",
    "20": "BTU",
    "80": "m3",
    "83": "US gallon"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 512,
   "documented": "30513 - 30514",
   "name": "Auxiliary A2",
   "description": "Pulse input A2 counter; unit per 30511.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 514,
   "documented": "30515 - 30516",
   "name": "Auxiliary A2 stored ST1",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 516,
   "documented": "30517 - 30518",
   "name": "Auxiliary A2 stored ST2",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 700,
   "documented": "30701",
   "name": "Power unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "47": "W",
    "48": "kW"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 702,
   "documented": "30703 - 30704",
   "name": "Power",
   "description": "Unit per 30701.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 710,
   "documented": "30711",
   "name": "Flow unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "135": "m3/h"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 712,
   "documented": "30713 - 30714",
   "name": "Flow",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m3/h",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 720,
   "documented": "30721",
   "name": "Temperature unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "62": "°C"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 722,
   "documented": "30723 - 30724",
   "name": "High temperature",
   "description": "Hot-side temperature.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 724,
   "documented": "30725 - 30726",
   "name": "Low temperature",
   "description": "Cold-side temperature.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 730,
   "documented": "30731",
   "name": "Delta temperature unit (float block)",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "63": "K"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "input_register",
   "address": 732,
   "documented": "30733 - 30734",
   "name": "Delta temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "K",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 10,
   "documented": "40011",
   "name": "Actual date: year",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 11,
   "documented": "40012",
   "name": "Actual date: month",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 12,
   "documented": "40013",
   "name": "Actual date: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 13,
   "documented": "40014",
   "name": "Actual time: hour",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 14,
   "documented": "40015",
   "name": "Actual time: minute",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 15,
   "documented": "40016",
   "name": "Actual time: second",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16,
   "documented": "40017",
   "name": "Password 'Communication'",
   "description": "Must be written (1234) in the same telegram as new comm settings.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 17,
   "documented": "40018",
   "name": "Modbus address",
   "description": "1-247.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 18,
   "documented": "40019",
   "name": "Parity",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "None",
    "1": "Odd",
    "2": "Even"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 19,
   "documented": "40020",
   "name": "Flow control (transmission mode)",
   "description": "Source lists 'MB_RTU=0, MB_RTU=1'; see notes.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20,
   "documented": "40021",
   "name": "Stop bits",
   "description": "1 or 2.",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 22,
   "documented": "40023 - 40024",
   "name": "Custom ID",
   "description": "OEM serial number.",
   "data_type": "UINT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24,
   "documented": "40025",
   "name": "Password 'Set Day'",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 25,
   "documented": "40026",
   "name": "Set-Day 1: month",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 26,
   "documented": "40027",
   "name": "Set-Day 1: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 27,
   "documented": "40028",
   "name": "Set-Day 2: month",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 28,
   "documented": "40029",
   "name": "Set-Day 2: day",
   "description": "",
   "data_type": "UINT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Fit the Modbus module, wire D0/D1/Common, and poll input registers with function 04 using low-word-first floats: energy 30103, volume 30303, power 30703, flow 30713 and temperatures 30723/30725/30733, plus their unit codes. Discrete inputs 10001-10016 report meter errors.",
  "minimum_registers": [
   {
    "table": "input_register",
    "address": 100,
    "why": "Energy unit code"
   },
   {
    "table": "input_register",
    "address": 102,
    "why": "Energy totalizer (float)"
   },
   {
    "table": "input_register",
    "address": 302,
    "why": "Volume (float)"
   },
   {
    "table": "input_register",
    "address": 702,
    "why": "Power (float)"
   },
   {
    "table": "input_register",
    "address": 712,
    "why": "Flow (float)"
   },
   {
    "table": "input_register",
    "address": 722,
    "why": "High temperature"
   },
   {
    "table": "input_register",
    "address": 724,
    "why": "Low temperature"
   },
   {
    "table": "discrete_input",
    "address": 2,
    "why": "Flow error flag"
   }
  ],
  "enable": "The integrator detects the module automatically once it is plugged into a module slot; no setting is needed. Baud rate is set with DIP switch S2 (default 19200), bias and termination with DIP switch S1.",
  "watchdog": null,
  "quirks": [
   "32-bit values are low word first (CDAB) even though the tables say '(h-l)'.",
   "Each float block has a unit register two registers before the value; read it once to know whether energy is kWh, MWh or GJ."
  ],
  "setup": [
   "Defaults: address 1, RTU, 19200 baud, 8 data bits, even parity, 1 stop bit.",
   "Address, parity, stop bits and RTU/ASCII can be changed over Modbus by writing 40017 (password) through the wanted register in one telegram; the module then reboots and is silent for 30-60 s. Do not power it down for 90-120 s.",
   "If settings are changed with Prog531/449 over the optical port, the module must be power-cycled (wait 15 s, power off at least 10 s) before they take effect.",
   "In ASCII mode with no parity the module uses 2 stop bits automatically."
  ],
  "gotchas": [
   "The module needs integrator firmware 3.7 or later.",
   "The module is powered from the integrator's mains supply board or an external 12 VDC / 150 mA supply; without that supply it will not answer."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/sontex/supercal-531-modbus-module",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}