 "manufacturer": "Studer Innotec",
 "manufacturer_slug": "studer-innotec",
 "model": "VarioString MPPT solar charge controller (via Xcom-485i)",
 "model_slug": "variostring",
 "short_model": "VarioString",
 "aliases": [
  "VS-70",
  "VS-120",
  "VarioString VS-120",
  "Xcom-485i"
 ],
 "equipment_type": "Solar inverter (MPPT solar charge controller)",
 "applies_to": "Studer VarioString VS-70 and VS-120 MPPT chargers read through an Xcom-485i Modbus RTU gateway, system release R706.",
 "summary": "VarioString is Studer's high-voltage MPPT solar charge controller for Xtender systems; the VS-120 has two PV inputs. An Xcom-485i on the Studer bus answers Modbus RTU for each VarioString. This map lists its user infos (battery, PV and PV1/PV2, production counters, state, errors) as input registers and its parameters as holding registers.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 41,
  "baud": null,
  "parity": "Even",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "0-based",
  "note": "The appendix lists the register exactly as it goes in the request. The protocol spec's example reads info 3001 from register 2 with start address 0x0002 in the frame, and parameter 1107 from register 14 (0x000E)."
 },
 "default_word_order": "ABCD",
 "firmware": "Studer system release R706 (appendix V1.6.44); Xcom-485i protocol V1.1.3",
 "source": {
  "title": "Technical specification Studer Modbus RTU Appendix V1.6.44 (with Technical specification Studer Modbus RTU Protocol V1.1.3)",
  "doc_number": "Appendix V1.6.44 (R706); Protocol V1.1.3",
  "revision_date": "2025-09-03",
  "url": "https://studer-innotec.com/wp-content/uploads/2025/09/Manuel-xcom-485i-technical-specification.zip",
  "pages": "Appendix pp. 45-58 (VarioString parameters pp. 45-53, VarioString infos pp. 53-58); Protocol spec pp. 4-8 (bus settings, unit addressing), pp. 18-25 (examples, offsets, encoding). Both PDFs are inside the ZIP."
 },
 "notes": [
  "PV1/PV2 items apply to the two-input VS-120; on a VS-70 use the plain PV items.",
  "Every info and parameter is an IEEE 754 single-precision float in two registers, high word first. The protocol spec's example reads Xtender info 3001 as 0x41D3 0x3333 = 26.4 °C, and parameter 1107 as 0x4170 0x0000 = 15.0 A.",
  "Each request must read or write exactly 2 registers (one value); asking for more returns an exception. Infos use function 04, parameters function 03 to read and 16 to write.",
  "Parameter registers have three more views at fixed offsets: +2000 = minimum allowed value, +4000 = maximum allowed value (read only), +6000 = write to RAM only. Use the RAM-only offset for anything written repeatedly; flash is only guaranteed for about 1000 writes per parameter.",
  "Enumerated infos count 0, 1, 2 ...; enumerated parameters use one bit per option (1, 2, 4, 8), still sent as a float. Codes shown as '---' in the appendix are unused and left out of the value lists.",
  "Register names keep the Studer info/parameter number in braces, e.g. {3000}. The register is 2 x (number - base) for that device family.",
  "Parameters whose appendix format is MENU are menu headings, not values, and are left out. The appendix's per-row remarks column is not reproduced.",
  "The gateway's own input registers (pending messages at 0-4, device counts at 5-9, gateway identity at 10-14, on unit 1) and the system clock (holding registers 0-7 on unit 2) are described in the protocol spec but live at other unit IDs, so they are not in this register list.",
  "The protocol spec's first read example prints the value as 0x4170 in the PDU table but 0x41F0 in the serial-line frame; 0x4170 matches the stated 15.0 A.",
  "Infos 15103, 15108, 15109 and 15111 (last page of the VarioString info table) were added at verification."
 ],
 "registers": [
  {
   "table": "input_register",
   "address": 0,
   "documented": "0",
   "name": "Battery voltage {15000}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 2,
   "documented": "2",
   "name": "Battery current {15001}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 4,
   "documented": "4",
   "name": "Battery cycle phase {15002}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Bulk",
    "1": "Absorpt.",
    "2": "Equalize",
    "3": "Floating",
    "6": "R.float.",
    "7": "Per.abs."
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 6,
   "documented": "6",
   "name": "PV type of wiring {15003}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Unknown",
    "1": "Independ.",
    "2": "Series",
    "3": "Parallel",
    "4": "Error"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 8,
   "documented": "8",
   "name": "PV voltage {15004}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 10,
   "documented": "10",
   "name": "PV1 voltage {15005}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 12,
   "documented": "12",
   "name": "PV2 voltage {15006}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 14,
   "documented": "14",
   "name": "PV current {15007}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 16,
   "documented": "16",
   "name": "PV1 current {15008}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 18,
   "documented": "18",
   "name": "PV2 current {15009}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 20,
   "documented": "20",
   "name": "PV power {15010}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 22,
   "documented": "22",
   "name": "PV1 power {15011}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 24,
   "documented": "24",
   "name": "PV2 power {15012}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 26,
   "documented": "26",
   "name": "PV operating mode {15013}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Night",
    "1": "Security",
    "2": "OFF",
    "3": "Charge",
    "4": "ChargeV",
    "5": "Charge I",
    "6": "ChargeP",
    "7": "ChargeIpv",
    "8": "ChargeT",
    "10": "Ch.Ibsp"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 28,
   "documented": "28",
   "name": "PV1 operating mode {15014}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Night",
    "1": "Security",
    "2": "OFF",
    "3": "Charge",
    "4": "ChargeV",
    "5": "Charge I",
    "6": "ChargeP",
    "7": "ChargeIpv",
    "8": "ChargeT",
    "10": "Ch.Ibsp"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 30,
   "documented": "30",
   "name": "PV2 operating mode {15015}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Night",
    "1": "Security",
    "2": "OFF",
    "3": "Charge",
    "4": "ChargeV",
    "5": "Charge I",
    "6": "ChargeP",
    "7": "ChargeIpv",
    "8": "ChargeT",
    "10": "Ch.Ibsp"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 32,
   "documented": "32",
   "name": "Production PV in (Ah) for the current day {15016}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 34,
   "documented": "34",
   "name": "Production PV in (kWh) for the current day {15017}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 36,
   "documented": "36",
   "name": "Production PV1 in (kWh) for the current day {15018}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 38,
   "documented": "38",
   "name": "Production PV2 in (kWh) for the current day {15019}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 40,
   "documented": "40",
   "name": "Produced PV energy resettable counter {15020}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 42,
   "documented": "42",
   "name": "Produced PV1 energy resettable counter {15021}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 44,
   "documented": "44",
   "name": "Produced PV2 energy resettable counter {15022}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 46,
   "documented": "46",
   "name": "Total PV produced energy {15023}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "MWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 48,
   "documented": "48",
   "name": "Total PV1 produced energy {15024}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "MWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 50,
   "documented": "50",
   "name": "Total PV2 produced energy {15025}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "MWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 52,
   "documented": "52",
   "name": "Production PV in (Ah) for the previous day {15026}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Ah",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 54,
   "documented": "54",
   "name": "Production PV in (Wh) for the previous day {15027}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 56,
   "documented": "56",
   "name": "Production PV1 in (Wh) for the previous day {15028}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 58,
   "documented": "58",
   "name": "Production PV2 in (Wh) for the previous day {15029}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kWh",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 60,
   "documented": "60",
   "name": "Number of irradiation hours for the current day {15030}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 62,
   "documented": "62",
   "name": "Number of irradiation hours for the previous day {15031}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 64,
   "documented": "64",
   "name": "Battery temperature {15032}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 66,
   "documented": "66",
   "name": "Max PV voltage for the current day {15033}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 68,
   "documented": "68",
   "name": "Max PV1 voltage for the current day {15034}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 70,
   "documented": "70",
   "name": "Max PV2 voltage for the current day {15035}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 72,
   "documented": "72",
   "name": "Max battery current of the current day {15036}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 74,
   "documented": "74",
   "name": "Max PV power for the current day {15037}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 76,
   "documented": "76",
   "name": "Max PV1 power for the current day {15038}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 78,
   "documented": "78",
   "name": "Max PV2 power for the current day {15039}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 80,
   "documented": "80",
   "name": "Max battery voltage for the current day {15040}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 82,
   "documented": "82",
   "name": "Min battery voltage for the current day {15041}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 84,
   "documented": "84",
   "name": "Time in absorption of the current day {15042}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "h",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 86,
   "documented": "86",
   "name": "BAT- and Earth voltage {15043}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 88,
   "documented": "88",
   "name": "PV- and Earth voltage {15044}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 90,
   "documented": "90",
   "name": "PV1- and Earth voltage {15045}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 92,
   "documented": "92",
   "name": "PV2- and Earth voltage {15046}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 98,
   "documented": "98",
   "name": "Type of error {15049}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "None",
    "1": "OverV_B",
    "2": "OverV_PV",
    "3": "OverV_PV1",
    "4": "OverV_PV2",
    "5": "OverI_PV",
    "6": "OverI_PV1",
    "7": "OverI_PV2",
    "8": "GroundBat",
    "9": "GroundPV",
    "10": "GroundPV1",
    "11": "GroundPV2",
    "12": "OverTemp",
    "13": "UnderV_B",
    "14": "Cabling",
    "15": "Other"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 100,
   "documented": "100",
   "name": "Synchronized with Xtender battery cycle {15050}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 102,
   "documented": "102",
   "name": "Synchronisation state {15051}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "4": "XTslave",
    "5": "VTslave",
    "8": "VTmaster",
    "9": "Autonom",
    "10": "VSslave",
    "11": "VSmaster"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 104,
   "documented": "104",
   "name": "Number of days before next equalization {15052}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 106,
   "documented": "106",
   "name": "Battery set point {15053}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 108,
   "documented": "108",
   "name": "Battery voltage (minute avg) {15054}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 110,
   "documented": "110",
   "name": "Battery voltage (minute max) {15055}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 112,
   "documented": "112",
   "name": "Battery voltage (minute min) {15056}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 114,
   "documented": "114",
   "name": "Battery current (minute avg) {15057}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 116,
   "documented": "116",
   "name": "PV voltage (minute avg) {15058}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 118,
   "documented": "118",
   "name": "PV1 voltage (minute avg) {15059}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 120,
   "documented": "120",
   "name": "PV2 voltage (minute avg) {15060}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 122,
   "documented": "122",
   "name": "PV power (minute avg) {15061}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 124,
   "documented": "124",
   "name": "PV1 power (minute avg) {15062}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 126,
   "documented": "126",
   "name": "PV2 power (minute avg) {15063}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "kW",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 128,
   "documented": "128",
   "name": "Battery temperature (minute avg) {15064}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 130,
   "documented": "130",
   "name": "Electronic temperature 1 (minute avg) {15065}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 132,
   "documented": "132",
   "name": "Electronic temperature 1 (minute max) {15066}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 134,
   "documented": "134",
   "name": "Electronic temperature 1 (minute min) {15067}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 136,
   "documented": "136",
   "name": "Electronic temperature 2 (minute avg) {15068}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 138,
   "documented": "138",
   "name": "Electronic temperature 2 (minute max) {15069}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 140,
   "documented": "140",
   "name": "Electronic temperature 2 (minute min) {15070}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 142,
   "documented": "142",
   "name": "Number of parameters (in code) {15071}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 144,
   "documented": "144",
   "name": "Number of parameters (in flash) {15072}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 146,
   "documented": "146",
   "name": "Number of infos users {15073}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 148,
   "documented": "148",
   "name": "ID type {15074}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 150,
   "documented": "150",
   "name": "ID bat voltage {15075}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 152,
   "documented": "152",
   "name": "ID HW {15076}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 154,
   "documented": "154",
   "name": "ID SOFT msb {15077}",
   "description": "Software version word, encoded as in the protocol spec's version section.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 156,
   "documented": "156",
   "name": "ID SOFT lsb {15078}",
   "description": "Software version word, encoded as in the protocol spec's version section.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 158,
   "documented": "158",
   "name": "ID SID {15079}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 176,
   "documented": "176",
   "name": "State of auxiliary Aux 1 {15088}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Opened",
    "1": "Closed"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 178,
   "documented": "178",
   "name": "State of auxiliary Aux 2 {15089}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Opened",
    "1": "Closed"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 180,
   "documented": "180",
   "name": "Relay Aux 1 mode {15090}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "A",
    "2": "I",
    "3": "M",
    "4": "M"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 182,
   "documented": "182",
   "name": "Relay Aux 2 mode {15091}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "1": "A",
    "2": "I",
    "3": "M",
    "4": "M"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 204,
   "documented": "204",
   "name": "ID FID msb {15102}",
   "description": "Half of the unit's unique FID number.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 206,
   "documented": "206",
   "name": "ID FID lsb {15103}",
   "description": "Half of the unit's unique FID number.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 216,
   "documented": "216",
   "name": "State of the VarioString {15108}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "Off",
    "1": "On"
   },
   "bits": null
  },
  {
   "table": "input_register",
   "address": 218,
   "documented": "218",
   "name": "Local daily communication error counter (CAN) {15109}",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null
  },
  {
   "table": "input_register",
   "address": 222,
   "documented": "222",
   "name": "Remote entry state {15111}",
   "description": "Enumerated state, sent as a float (1.0 = code 1).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "R",
   "values": {
    "0": "RM EN 0",
    "1": "RM EN 1"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 2,
   "documented": "2",
   "name": "Battery charge current (VS-120) {14001}",
   "description": "Expert level. Range 0 to 120, default 120.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Adc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 4,
   "documented": "4",
   "name": "Configuration of PV modules (VS-120) {14002}",
   "description": "Basic level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Automatic",
    "2": "Independent",
    "4": "Serial",
    "8": "Parallel"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 10,
   "documented": "10",
   "name": "Floating voltage {14005}",
   "description": "Expert level. Range 37.9 to 68.2, default 54.4.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 12,
   "documented": "12",
   "name": "Force phase of floating {14006}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 16,
   "documented": "16",
   "name": "Absorption phase allowed {14008}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 18,
   "documented": "18",
   "name": "Absorption voltage {14009}",
   "description": "Expert level. Range 37.9 to 68.2, default 57.6.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 20,
   "documented": "20",
   "name": "Force absorption phase {14010}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 22,
   "documented": "22",
   "name": "Absorption duration {14011}",
   "description": "Expert level. Range 5 to 510, default 120.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 24,
   "documented": "24",
   "name": "End of absorption triggered by the current {14012}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 26,
   "documented": "26",
   "name": "Current threshold to end absorption phase {14013}",
   "description": "Expert level. Range 2 to 120, default 10.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Adc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 34,
   "documented": "34",
   "name": "Equalization allowed {14017}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 36,
   "documented": "36",
   "name": "Force equalization {14018}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 38,
   "documented": "38",
   "name": "Equalization before absorption phase {14019}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 40,
   "documented": "40",
   "name": "Equalization current {14020}",
   "description": "Expert level. Range 2 to 120, default 80.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Adc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 42,
   "documented": "42",
   "name": "Equalization voltage {14021}",
   "description": "Expert level. Range 52.1 to 68.2, default 62.4.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 44,
   "documented": "44",
   "name": "Equalization duration {14022}",
   "description": "Expert level. Range 5 to 510, default 30.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 46,
   "documented": "46",
   "name": "Equalization with fixed interval {14023}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 48,
   "documented": "48",
   "name": "Days between equalizations {14024}",
   "description": "Expert level. Range 1 to 365, default 26.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "days",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 50,
   "documented": "50",
   "name": "End of equalization triggered by the current {14025}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 52,
   "documented": "52",
   "name": "Current threshold to end equalization phase {14026}",
   "description": "Expert level. Range 4 to 30, default 10.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Adc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 56,
   "documented": "56",
   "name": "Force a new cycle {14028}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 58,
   "documented": "58",
   "name": "Voltage level 1 to start a new cycle {14029}",
   "description": "Expert level. Range 37.9 to 68.2, default 48.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 60,
   "documented": "60",
   "name": "Time period under voltage level 1 to start a new cycle {14030}",
   "description": "Expert level. Range 0 to 240, default 30.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 62,
   "documented": "62",
   "name": "Voltage level 2 to start a new cycle {14031}",
   "description": "Expert level. Range 37.9 to 68.2, default 47.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 64,
   "documented": "64",
   "name": "Time period under voltage level 2 to start a new cycle {14032}",
   "description": "Expert level. Range 0 to 240, default 2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 66,
   "documented": "66",
   "name": "Cycling restricted {14033}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 68,
   "documented": "68",
   "name": "Minimal delay between cycles {14034}",
   "description": "Expert level. Range 0 to 540, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 70,
   "documented": "70",
   "name": "Temperature compensation {14035}",
   "description": "Expert level. Range -8 to 0, default -3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "mV/°C/cell",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 72,
   "documented": "72",
   "name": "Synchronisation battery cycle with Xtender {14036}",
   "description": "Basic level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 76,
   "documented": "76",
   "name": "ON of the VarioString {14038}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 78,
   "documented": "78",
   "name": "OFF of the VarioString {14039}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 80,
   "documented": "80",
   "name": "Type of battery grounding {14040}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "No control",
    "2": "Bat+ grounded",
    "4": "Bat- grounded",
    "8": "Bat floating"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 82,
   "documented": "82",
   "name": "Type of PV grounding {14041}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "No control",
    "2": "PV+ grounded",
    "4": "PV- grounded",
    "8": "PV floating"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 84,
   "documented": "84",
   "name": "Type of PV2 grounding {14042}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "No control",
    "2": "PV+ grounded",
    "4": "PV- grounded",
    "8": "PV floating"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 86,
   "documented": "86",
   "name": "Type of MPP tracking algorithm PV {14043}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "P&O",
    "2": "OC ratio",
    "4": "Upv fixed",
    "8": "LSF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 88,
   "documented": "88",
   "name": "PV voltage fixed (for PV in series) {14044}",
   "description": "Expert level. Range 200 to 900, default 700.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 90,
   "documented": "90",
   "name": "Ratio of PV open circuit voltage {14045}",
   "description": "Expert level. Range 0.5 to 1, default 0.7.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 92,
   "documented": "92",
   "name": "Type of MPP tracking algorithm PV2 {14046}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "P&O",
    "2": "OC ratio",
    "4": "Upv fixed",
    "8": "LSF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 94,
   "documented": "94",
   "name": "PV2 voltage fixed {14047}",
   "description": "Expert level. Range 100 to 600, default 500.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 96,
   "documented": "96",
   "name": "Ratio of PV2 open circuit voltage {14048}",
   "description": "Expert level. Range 0.5 to 1, default 0.7.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 102,
   "documented": "102",
   "name": "Reset daily solar production meters {14051}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 104,
   "documented": "104",
   "name": "Reset daily min-max {14052}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 118,
   "documented": "118",
   "name": "Reset of all VarioString {14059}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 130,
   "documented": "130",
   "name": "Battery overvoltage level {14065}",
   "description": "Expert level. Range 37.9 to 68.2, default 68.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 132,
   "documented": "132",
   "name": "Restart voltage level after a battery overvoltage {14066}",
   "description": "Expert level. Range 37.9 to 68.2, default 64.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 134,
   "documented": "134",
   "name": "Restore default settings {14067}",
   "description": "Basic level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 136,
   "documented": "136",
   "name": "Restore factory settings {14068}",
   "description": "Installer level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 138,
   "documented": "138",
   "name": "Parameters saved in flash memory {14069}",
   "description": "Installer level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 142,
   "documented": "142",
   "name": "Operating mode (AUX 1) {14071}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Automatic",
    "2": "Reversed automatic",
    "4": "Manual ON",
    "8": "Manual OFF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 144,
   "documented": "144",
   "name": "Combination of the events for the auxiliary contact (AUX 1) {14072}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Any (Function OR)",
    "1": "All (Function AND)"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 148,
   "documented": "148",
   "name": "Activated in night mode (AUX 1) {14074}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 150,
   "documented": "150",
   "name": "Delay of activation after entering night mode (AUX 1) {14075}",
   "description": "Expert level. Range 0 to 1440, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 152,
   "documented": "152",
   "name": "Activation time for the auxiliary relay in night mode (AUX 1) {14076}",
   "description": "Expert level. Range 0 to 1440, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 156,
   "documented": "156",
   "name": "VarioString is OFF (AUX 1) {14078}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 158,
   "documented": "158",
   "name": "Battery undervoltage (AUX 1) {14079}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 160,
   "documented": "160",
   "name": "Battery overvoltage (AUX 1) {14080}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 162,
   "documented": "162",
   "name": "Earth fault (AUX 1) {14081}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 164,
   "documented": "164",
   "name": "PV error (48h without charge) (AUX 1) {14082}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 166,
   "documented": "166",
   "name": "Overtemperature (AUX 1) {14083}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 168,
   "documented": "168",
   "name": "Bulk charge phase (AUX 1) {14084}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 170,
   "documented": "170",
   "name": "Absorption phase (AUX 1) {14085}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 172,
   "documented": "172",
   "name": "Equalization phase (AUX 1) {14086}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 174,
   "documented": "174",
   "name": "Floating (AUX 1) {14087}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 176,
   "documented": "176",
   "name": "Reduced floating (AUX 1) {14088}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 178,
   "documented": "178",
   "name": "Periodic absorption (AUX 1) {14089}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 182,
   "documented": "182",
   "name": "Battery voltage 1 activate (AUX 1) {14091}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 184,
   "documented": "184",
   "name": "Battery voltage 1 (AUX 1) {14092}",
   "description": "Expert level. Range 36 to 72, default 46.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 186,
   "documented": "186",
   "name": "Delay 1 (AUX 1) {14093}",
   "description": "Expert level. Range 0 to 60, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 188,
   "documented": "188",
   "name": "Battery voltage 2 activate (AUX 1) {14094}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 190,
   "documented": "190",
   "name": "Battery voltage 2 (AUX 1) {14095}",
   "description": "Expert level. Range 36 to 72, default 47.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 192,
   "documented": "192",
   "name": "Delay 2 (AUX 1) {14096}",
   "description": "Expert level. Range 0 to 60, default 10.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 194,
   "documented": "194",
   "name": "Battery voltage 3 activate (AUX 1) {14097}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 196,
   "documented": "196",
   "name": "Battery voltage 3 (AUX 1) {14098}",
   "description": "Expert level. Range 36 to 72, default 48.5.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 198,
   "documented": "198",
   "name": "Delay 3 (AUX 1) {14099}",
   "description": "Expert level. Range 0 to 60, default 60.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 200,
   "documented": "200",
   "name": "Battery voltage to deactivate (AUX 1) {14100}",
   "description": "Expert level. Range 36 to 72, default 54.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 202,
   "documented": "202",
   "name": "Delay to deactivate (AUX 1) {14101}",
   "description": "Expert level. Range 0 to 480, default 60.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 204,
   "documented": "204",
   "name": "Deactivate if battery in floating phase (AUX 1) {14102}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 208,
   "documented": "208",
   "name": "Contact activated with the temperature of battery (AUX 1) {14104}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 210,
   "documented": "210",
   "name": "Contact activated over (AUX 1) {14105}",
   "description": "Expert level. Range -10 to 50, default 3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 212,
   "documented": "212",
   "name": "Contact deactivated below (AUX 1) {14106}",
   "description": "Expert level. Range -10 to 50, default 5.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 214,
   "documented": "214",
   "name": "Only activated if the battery is not in bulk phase (AUX 1) {14107}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 218,
   "documented": "218",
   "name": "Contact activated with the SOC 1 of battery (AUX 1) {14109}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 220,
   "documented": "220",
   "name": "Contact activated below SOC 1 (AUX 1) {14110}",
   "description": "Expert level. Range 0 to 100, default 50.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "% SOC",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 222,
   "documented": "222",
   "name": "Delay 1 (AUX 1) {14111}",
   "description": "Expert level. Range 0 to 99, default 12.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 224,
   "documented": "224",
   "name": "Contact activated with the SOC 2 of battery (AUX 1) {14112}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 226,
   "documented": "226",
   "name": "Contact activated below SOC 2 (AUX 1) {14113}",
   "description": "Expert level. Range 0 to 100, default 30.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 228,
   "documented": "228",
   "name": "Delay 2 (AUX 1) {14114}",
   "description": "Expert level. Range 0 to 99, default 0.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 230,
   "documented": "230",
   "name": "Contact activated with the SOC 3 of battery (AUX 1) {14115}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 232,
   "documented": "232",
   "name": "Contact activated below SOC 3 (AUX 1) {14116}",
   "description": "Expert level. Range 0 to 100, default 20.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 234,
   "documented": "234",
   "name": "Delay 3 (AUX 1) {14117}",
   "description": "Expert level. Range 0 to 99, default 0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 236,
   "documented": "236",
   "name": "Contact deactivated over SOC (AUX 1) {14118}",
   "description": "Expert level. Range 0 to 100, default 90.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "% SOC",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 238,
   "documented": "238",
   "name": "Delay to deactivate (AUX 1) {14119}",
   "description": "Expert level. Range 0 to 10, default 0.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 240,
   "documented": "240",
   "name": "Deactivate if battery in floating phase (AUX 1) {14120}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 242,
   "documented": "242",
   "name": "Reset all settings (AUX 1) {14121}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 246,
   "documented": "246",
   "name": "Operating mode (AUX 2) {14123}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Automatic",
    "2": "Reversed automatic",
    "4": "Manual ON",
    "8": "Manual OFF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 248,
   "documented": "248",
   "name": "Combination of the events for the auxiliary contact (AUX 2) {14124}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Any (Function OR)",
    "1": "All (Function AND)"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 252,
   "documented": "252",
   "name": "Activated in night mode (AUX 2) {14126}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 254,
   "documented": "254",
   "name": "Delay of activation after entering night mode (AUX 2) {14127}",
   "description": "Expert level. Range 0 to 1440, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 256,
   "documented": "256",
   "name": "Activation time for the auxiliary relay in night mode (AUX 2) {14128}",
   "description": "Expert level. Range 0 to 1440, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 260,
   "documented": "260",
   "name": "VarioString is OFF (AUX 2) {14130}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 262,
   "documented": "262",
   "name": "Battery undervoltage (AUX 2) {14131}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 264,
   "documented": "264",
   "name": "Battery overvoltage (AUX 2) {14132}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 266,
   "documented": "266",
   "name": "Earth fault (AUX 2) {14133}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 268,
   "documented": "268",
   "name": "PV error (48h without charge) (AUX 2) {14134}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 270,
   "documented": "270",
   "name": "Overtemperature (AUX 2) {14135}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 272,
   "documented": "272",
   "name": "Bulk charge phase (AUX 2) {14136}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 274,
   "documented": "274",
   "name": "Absorption phase (AUX 2) {14137}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 276,
   "documented": "276",
   "name": "Equalization phase (AUX 2) {14138}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 278,
   "documented": "278",
   "name": "Floating (AUX 2) {14139}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 280,
   "documented": "280",
   "name": "Reduced floating (AUX 2) {14140}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 282,
   "documented": "282",
   "name": "Periodic absorption (AUX 2) {14141}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 286,
   "documented": "286",
   "name": "Battery voltage 1 activate (AUX 2) {14143}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 288,
   "documented": "288",
   "name": "Battery voltage 1 (AUX 2) {14144}",
   "description": "Expert level. Range 36 to 72, default 46.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 290,
   "documented": "290",
   "name": "Delay 1 (AUX 2) {14145}",
   "description": "Expert level. Range 0 to 60, default 1.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 292,
   "documented": "292",
   "name": "Battery voltage 2 activate (AUX 2) {14146}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 294,
   "documented": "294",
   "name": "Battery voltage 2 (AUX 2) {14147}",
   "description": "Expert level. Range 36 to 72, default 47.8.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 296,
   "documented": "296",
   "name": "Delay 2 (AUX 2) {14148}",
   "description": "Expert level. Range 0 to 60, default 10.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 298,
   "documented": "298",
   "name": "Battery voltage 3 activate (AUX 2) {14149}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 300,
   "documented": "300",
   "name": "Battery voltage 3 (AUX 2) {14150}",
   "description": "Expert level. Range 36 to 72, default 48.5.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 302,
   "documented": "302",
   "name": "Delay 3 (AUX 2) {14151}",
   "description": "Expert level. Range 0 to 60, default 60.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 304,
   "documented": "304",
   "name": "Battery voltage to deactivate (AUX 2) {14152}",
   "description": "Expert level. Range 36 to 72, default 54.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 306,
   "documented": "306",
   "name": "Delay to deactivate (AUX 2) {14153}",
   "description": "Expert level. Range 0 to 480, default 60.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 308,
   "documented": "308",
   "name": "Deactivate if battery in floating phase (AUX 2) {14154}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 312,
   "documented": "312",
   "name": "Contact activated with the temperature of battery (AUX 2) {14156}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 314,
   "documented": "314",
   "name": "Contact activated over (AUX 2) {14157}",
   "description": "Expert level. Range -10 to 50, default 3.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 316,
   "documented": "316",
   "name": "Contact deactivated below (AUX 2) {14158}",
   "description": "Expert level. Range -10 to 50, default 5.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "°C",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 318,
   "documented": "318",
   "name": "Only activated if the battery is not in bulk phase (AUX 2) {14159}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 322,
   "documented": "322",
   "name": "Contact activated with the SOC 1 of battery (AUX 2) {14161}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 324,
   "documented": "324",
   "name": "Contact activated below SOC 1 (AUX 2) {14162}",
   "description": "Expert level. Range 0 to 100, default 50.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "% SOC",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 326,
   "documented": "326",
   "name": "Delay 1 (AUX 2) {14163}",
   "description": "Expert level. Range 0 to 99, default 12.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 328,
   "documented": "328",
   "name": "Contact activated with the SOC 2 of battery (AUX 2) {14164}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 330,
   "documented": "330",
   "name": "Contact activated below SOC 2 (AUX 2) {14165}",
   "description": "Expert level. Range 0 to 100, default 30.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 332,
   "documented": "332",
   "name": "Delay 2 (AUX 2) {14166}",
   "description": "Expert level. Range 0 to 99, default 0.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 334,
   "documented": "334",
   "name": "Contact activated with the SOC 3 of battery (AUX 2) {14167}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 336,
   "documented": "336",
   "name": "Contact activated below SOC 3 (AUX 2) {14168}",
   "description": "Expert level. Range 0 to 100, default 20.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "%",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 338,
   "documented": "338",
   "name": "Delay 3 (AUX 2) {14169}",
   "description": "Expert level. Range 0 to 99, default 0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 340,
   "documented": "340",
   "name": "Contact deactivated over SOC (AUX 2) {14170}",
   "description": "Expert level. Range 0 to 100, default 90.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "% SOC",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 342,
   "documented": "342",
   "name": "Delay to deactivate (AUX 2) {14171}",
   "description": "Expert level. Range 0 to 10, default 0.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "hours",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 344,
   "documented": "344",
   "name": "Deactivate if battery in floating phase (AUX 2) {14172}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 346,
   "documented": "346",
   "name": "Reset all settings (AUX 2) {14173}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 348,
   "documented": "348",
   "name": "Block manual programming (dip-switch) {14174}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 350,
   "documented": "350",
   "name": "Type of PV1 grounding {14175}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "No control",
    "2": "PV+ grounded",
    "4": "PV- grounded",
    "8": "PV floating"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 352,
   "documented": "352",
   "name": "Type of MPP tracking algorithm PV1 {14176}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "P&O",
    "2": "OC ratio",
    "4": "Upv fixed",
    "8": "LSF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 354,
   "documented": "354",
   "name": "PV1 voltage fixed {14177}",
   "description": "Expert level. Range 100 to 600, default 500.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 356,
   "documented": "356",
   "name": "Ratio of PV1 open circuit voltage {14178}",
   "description": "Expert level. Range 0.5 to 1, default 0.7.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 358,
   "documented": "358",
   "name": "PV voltage fixed (for PV in //) {14179}",
   "description": "Expert level. Range 100 to 600, default 500.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 364,
   "documented": "364",
   "name": "Reset PV energy meter {14182}",
   "description": "Expert level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 366,
   "documented": "366",
   "name": "Reset total produced PV energy meter {14183}",
   "description": "Qualified service level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 376,
   "documented": "376",
   "name": "VarioString is ON (AUX 1) {14188}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 378,
   "documented": "378",
   "name": "VarioString is ON (AUX 2) {14189}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 380,
   "documented": "380",
   "name": "PV wiring type erased from memory {14190}",
   "description": "Installer level. Write 1.0 to trigger.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "W",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 384,
   "documented": "384",
   "name": "Establishment time (Algo MPPT) {14192}",
   "description": "Installer level. Range 0 to 300, default 0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "sec",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 386,
   "documented": "386",
   "name": "Averaging time (Algo MPPT) {14193}",
   "description": "Installer level. Range 0 to 300, default 0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "sec",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 392,
   "documented": "392",
   "name": "Type of PV grounding {14196}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "No control",
    "2": "PV+ grounded",
    "4": "PV- grounded",
    "8": "PV floating"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 394,
   "documented": "394",
   "name": "Type of MPP tracking algorithm PV {14197}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "P&O",
    "2": "OC ratio",
    "4": "Upv fixed",
    "8": "LSF"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 396,
   "documented": "396",
   "name": "PV voltage fixed {14198}",
   "description": "Expert level. Range 100 to 600, default 500.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 398,
   "documented": "398",
   "name": "Ratio of PV open circuit voltage {14199}",
   "description": "Expert level. Range 0.5 to 1, default 0.7.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 402,
   "documented": "402",
   "name": "Remote entry active {14201}",
   "description": "Expert level. Option code as a float; one option at a time.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "1": "Closed",
    "2": "Open",
    "4": "Edge"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 404,
   "documented": "404",
   "name": "ON/OFF command {14202}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 406,
   "documented": "406",
   "name": "Activated by AUX1 state {14203}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 408,
   "documented": "408",
   "name": "Start equalization {14204}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 410,
   "documented": "410",
   "name": "Send a message when remote entry changes state {14205}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 414,
   "documented": "414",
   "name": "Contact activated with fixed time schedule (AUX 1) {14207}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 416,
   "documented": "416",
   "name": "Start hour (AUX 1) {14208}",
   "description": "Expert level. Minutes after midnight as a float (0-1440).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 418,
   "documented": "418",
   "name": "End hour (AUX 1) {14209}",
   "description": "Expert level. Minutes after midnight as a float (0-1440).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 422,
   "documented": "422",
   "name": "Contact activated with fixed time schedule (AUX 2) {14211}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 424,
   "documented": "424",
   "name": "Start hour (AUX 2) {14212}",
   "description": "Expert level. Minutes after midnight as a float (0-1440).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 426,
   "documented": "426",
   "name": "End hour (AUX 2) {14213}",
   "description": "Expert level. Minutes after midnight as a float (0-1440).",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "min",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 428,
   "documented": "428",
   "name": "Remote entry (AUX 1) {14214}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 430,
   "documented": "430",
   "name": "Remote entry (AUX 2) {14215}",
   "description": "Expert level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 432,
   "documented": "432",
   "name": "Battery undervoltage {14216}",
   "description": "Expert level. Range 34 to 68.2, default 40.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Vdc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 434,
   "documented": "434",
   "name": "Battery charge current (VS-70) {14217}",
   "description": "Expert level. Range 0 to 70, default 70.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "Adc",
   "access": "RW",
   "values": null,
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 436,
   "documented": "436",
   "name": "VarioString watchdog enabled (SCOM) {14218}",
   "description": "Installer level. Float 0.0 = no, 1.0 = yes.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "",
   "access": "RW",
   "values": {
    "0": "No",
    "1": "Yes"
   },
   "bits": null
  },
  {
   "table": "holding_register",
   "address": 438,
   "documented": "438",
   "name": "VarioString watchdog delay (SCOM) {14219}",
   "description": "Installer level. Range 10 to 300, default 60.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "ABCD",
   "scale": 1,
   "offset": 0,
   "scale_factor_ref": null,
   "units": "sec",
   "access": "RW",
   "values": null,
   "bits": null
  }
 ],
 "integration": {
  "summary": "Fit an Xcom-485i on the Studer communication bus and poll it as a Modbus RTU slave. Each Studer device answers at its own unit ID (offset set by DIP switches 1-2); read infos with function 04 and parameters with 03, always 2 registers at a time, and decode as big-endian float.",
  "minimum_registers": [
   {
    "table": "input_register",
    "address": 0,
    "why": "Battery voltage"
   },
   {
    "table": "input_register",
    "address": 2,
    "why": "Battery current"
   },
   {
    "table": "input_register",
    "address": 8,
    "why": "PV voltage"
   },
   {
    "table": "input_register",
    "address": 20,
    "why": "PV power"
   },
   {
    "table": "input_register",
    "address": 34,
    "why": "Energy produced today"
   },
   {
    "table": "input_register",
    "address": 46,
    "why": "Total produced energy"
   },
   {
    "table": "input_register",
    "address": 26,
    "why": "PV operating mode"
   },
   {
    "table": "input_register",
    "address": 98,
    "why": "Type of error"
   }
  ],
  "enable": "Install the Xcom-485i on the Studer bus. DIP switches 1-2 set the unit-ID offset (0, 32, 64 or 128) and switches 7-8 set the baud rate (9600, 19200, 38400 or 115200). Frames are 8 data bits, even parity, 1 stop bit.",
  "watchdog": null,
  "quirks": [
   "Unit 41 addresses the first VarioString; multicast unit 40 reads the first such device and writes to all of them at once.",
   "Values are floats even for on/off and enumerated items: 1.0 = 0x3F800000."
  ],
  "setup": [
   "With DIP 1-2 off: unit 1 = Xcom-485i gateway, 2 = system, 10 = all Xtenders, 11-19 = single Xtenders, 20 = all VarioTracks, 21-35 = single VarioTracks, 40 = all VarioStrings, 41-55 = single VarioStrings, 60 = all BSP/Xcom-CAN BMS, 61 = the single BSP or Xcom-CAN BMS. Add the DIP offset to each.",
   "Single devices are numbered in the order shown on the RCC remote's device list.",
   "Allow up to 1 s for a reply and send one request at a time; the gateway is slower when the Studer bus is busy."
  ],
  "gotchas": [
   "Writing a parameter at its base register stores it in flash; cyclic writes should use base + 6000 (RAM only).",
   "Some parameters restart an internal timer or algorithm when changed while running.",
   "Parameter levels (Basic/Expert/Installer/QSP) are the RCC access levels printed in the appendix."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/studer-innotec/variostring",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}