 "manufacturer": "Vaisala",
 "manufacturer_slug": "vaisala",
 "model": "RM60 PRECICAP radar precipitation sensor (Modbus RTU)",
 "model_slug": "rm60",
 "short_model": "RM60",
 "aliases": [
  "RM60",
  "PRECICAP RM60",
  "Vaisala RM60"
 ],
 "equipment_type": "Sensor (precipitation)",
 "applies_to": "RM60 sensors ordered with communication option 1 (RS-485 Modbus RTU) or switched to Modbus, per user guide M213218EN-B.",
 "summary": "The Vaisala RM60 is a compact radar precipitation sensor that reports rain intensity, accumulation, snow and precipitation type, plus air pressure when that measurement option is ordered. On RS-485 it serves Modbus RTU (or a text data message). This map covers the measurement floats, drop-size distribution, reset and interval settings, serial settings, status and diagnostic registers, device monitoring and the test registers.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 240,
  "baud": 19200,
  "parity": "Even",
  "data_bits": 8,
  "stop_bits": 1,
  "tcp_port": null
 },
 "addressing": {
  "convention": "hex 0-based",
  "note": "The guide prints each register as a hex address with its decimal value (sent on the wire as-is) plus a 'register number' that is the address + 1. The test registers start at 0x1F00, which the guide reads directly."
 },
 "default_word_order": "CDAB",
 "firmware": null,
 "source": {
  "title": "RM60 User Guide",
  "doc_number": "M213218EN-B",
  "revision_date": "2026-08",
  "url": "https://docs.vaisala.com/r/M213218EN-B/en-US",
  "pages": "pp. 26 (default settings), 29-31 (Modbus RTU protocol, data types), 68-73 (Appendix A Modbus registers)"
 },
 "notes": [
  "All registers are holding registers: read with function 03, write with function 16; function 43/14 reads device identification.",
  "int32 and float values are two registers in little-endian word order (least significant word first, CDAB), as the guide's data-type table states and its -123.45 test example shows. Bytes inside each register are big-endian.",
  "The 'differential' accumulation registers restart from zero each time they are read (or reset).",
  "Left out: DSD bins 2-21 (same pattern), the messaging address, autosend message and interval (data-messaging mode only), configuration code, manufacturing date, product name and the module identification strings.",
  "Air pressure (0x0020) is an additional measurement ordering option in the guide."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 32,
   "documented": "0x0020 (32)",
   "name": "Air pressure",
   "description": "Only with the air pressure ordering option.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "hPa",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34,
   "documented": "0x0022 (34)",
   "name": "Precipitation intensity",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "mm/h",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 36,
   "documented": "0x0024 (36)",
   "name": "Precipitation accumulation",
   "description": "Accumulates until reset.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "mm",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 38,
   "documented": "0x0026 (38)",
   "name": "Precipitation accumulation (differential)",
   "description": "Accumulates until read or reset.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "mm",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 42,
   "documented": "0x002a (42)",
   "name": "Precipitation type",
   "description": "SYNOP present-weather code.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 44,
   "documented": "0x002c (44)",
   "name": "Snow accumulation",
   "description": "Accumulates until reset.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "mm",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 46,
   "documented": "0x002e (46)",
   "name": "Snow accumulation (differential)",
   "description": "Accumulates until read or reset.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "mm",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 512,
   "documented": "0x0200 (512)",
   "name": "Device status",
   "description": "0 = device OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "2": "Warning (W)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 513,
   "documented": "0x0201 (513)",
   "name": "Device diagnostic code",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 515,
   "documented": "0x0203 (515)",
   "name": "Operating voltage status",
   "description": "0 = operating voltage OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "2": "Operating voltage too low (U)",
    "3": "Operating voltage too high (O)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 516,
   "documented": "0x0204 (516)",
   "name": "Operating voltage diagnostic code",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 536,
   "documented": "0x0218 (536)",
   "name": "Precipitation measurement status",
   "description": "0 = measurement OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Unavailable (S)",
    "1": "Unreliable (R)",
    "6": "Calibration expired (C)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 537,
   "documented": "0x0219 (537)",
   "name": "Precipitation measurement diagnostic code",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 790,
   "documented": "0x0316 (790)",
   "name": "Measurement interval",
   "description": "12-600 s, default 12.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1536,
   "documented": "0x0600 (1536)",
   "name": "Restart device",
   "description": "Write 1 to restart.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1538,
   "documented": "0x0602 (1538)",
   "name": "Bit rate",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1200",
    "1": "2400",
    "2": "4800",
    "3": "9600",
    "4": "19200",
    "5": "38400",
    "6": "57600",
    "7": "115200"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1539,
   "documented": "0x0603 (1539)",
   "name": "Parity, data, stop bits",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "N81",
    "1": "N82",
    "2": "E81",
    "3": "E82",
    "4": "O81",
    "5": "O82",
    "6": "N71",
    "7": "N72",
    "8": "E71",
    "9": "E72",
    "10": "O71",
    "11": "O72"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1541,
   "documented": "0x0605 (1541)",
   "name": "Interface mode",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Modbus RTU",
    "1": "Data messaging"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1542,
   "documented": "0x0606 (1542)",
   "name": "Modbus address",
   "description": "1-247, default 240.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7424,
   "documented": "0x1d00 (7424)",
   "name": "Vendor name",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7432,
   "documented": "0x1d08 (7432)",
   "name": "Product code",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7440,
   "documented": "0x1d10 (7440)",
   "name": "Product serial number",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7680,
   "documented": "0x1e00 (7680)",
   "name": "Restore factory default settings",
   "description": "Write 1 to start.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7936,
   "documented": "0x1f00 (7936)",
   "name": "Signed integer test",
   "description": "Always reads -12345.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7937,
   "documented": "0x1f01 (7937)",
   "name": "Floating point test",
   "description": "Always reads -123.45.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7939,
   "documented": "0x1f03 (7939)",
   "name": "Text string test",
   "description": "Reads the text \"-123.45\".",
   "data_type": "STRING",
   "length": 4,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 9472,
   "documented": "0x2500 (9472)",
   "name": "Reset accumulation counter",
   "description": "Write 1 to zero the four accumulation registers.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 9473,
   "documented": "0x2501 (9473)",
   "name": "Accumulation counter reset value",
   "description": "Accumulations roll to 0 at this value; 0-1000, default 1000.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "mm",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32768,
   "documented": "0x8000 (32768)",
   "name": "Uptime",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32770,
   "documented": "0x8002 (32770)",
   "name": "Operating voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32772,
   "documented": "0x8004 (32772)",
   "name": "Digital 3.3 V supply",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32774,
   "documented": "0x8006 (32774)",
   "name": "Digital 5 V supply",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32780,
   "documented": "0x800c (32780)",
   "name": "Device tilt angle",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34816,
   "documented": "0x8800 (34816)",
   "name": "Autocalibration",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": {
    "0": "Up to date",
    "1": "In progress"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34817,
   "documented": "0x8801 (34817)",
   "name": "Reflectivity factor",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "dBZ",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34819,
   "documented": "0x8803 (34819)",
   "name": "DSD bin 1",
   "description": "Drop size distribution; bins 2-22 follow every 2 registers.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m-3 mm-1",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 34861,
   "documented": "0x882d (34861)",
   "name": "DSD bin 22",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m-3 mm-1",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Read holding registers 0x0022-0x0027 for intensity and accumulation as low-word-first floats, 0x002A for precipitation type, and check the status words at 0x0200 and 0x0218.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 34,
    "why": "Precipitation intensity"
   },
   {
    "table": "holding_register",
    "address": 36,
    "why": "Precipitation accumulation"
   },
   {
    "table": "holding_register",
    "address": 42,
    "why": "Precipitation type (SYNOP)"
   },
   {
    "table": "holding_register",
    "address": 512,
    "why": "Device status"
   },
   {
    "table": "holding_register",
    "address": 536,
    "why": "Measurement status"
   }
  ],
  "enable": "Order communication option 1 (Modbus RTU), or set Interface mode to Modbus RTU in Insight PC software (Configure device > Communication), save, and power-cycle the sensor.",
  "watchdog": null,
  "quirks": [
   "Floats and int32 are low word first (CDAB).",
   "Reading a differential accumulation register resets it."
  ],
  "setup": [
   "Option 1 default: RS-485 Modbus RTU, 19200 baud, 8 data bits, even parity, 1 stop bit, address 240.",
   "After changing settings in Insight, the guide has you power-cycle the sensor (cable off for 5 s) before connecting the Modbus client."
  ],
  "gotchas": [
   "Read the test registers at 0x1F00-0x1F06 first to confirm addressing and word order."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/vaisala/rm60",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}