 "manufacturer": "Vaisala",
 "manufacturer_slug": "vaisala",
 "model": "WM80 ultrasonic wind sensor (Modbus RTU)",
 "model_slug": "wm80",
 "short_model": "WM80",
 "aliases": [
  "WM80",
  "Vaisala WM80",
  "Ultrasonic Wind Sensor WM80"
 ],
 "equipment_type": "Sensor (ultrasonic wind)",
 "applies_to": "WM80 sensors with RS-485 in Modbus mode (e.g. ordering option C), per user guide M212995EN-F.",
 "summary": "The Vaisala WM80 is a heated ultrasonic wind sensor aimed at uses that need continuous wind data, such as wind turbine control, ship navigation and dynamic positioning. On RS-485 it serves Modbus RTU or an ASCII/NMEA message. This map covers wind speed and direction (sample, instant, average, gust, lull, U/V components), sonic temperature, averaging and heating settings, serial settings, status words, monitoring values and test registers.",
 "transport": [
  "RTU"
 ],
 "defaults": {
  "unit_id": 240,
  "baud": 19200,
  "parity": "None",
  "data_bits": 8,
  "stop_bits": 2,
  "tcp_port": null
 },
 "addressing": {
  "convention": "hex 0-based",
  "note": "The guide prints each register as a hex address with its decimal value (used on the wire) plus a 'register number' equal to the address + 1. Wind speed sample is at address 0x0000 (register number 1)."
 },
 "default_word_order": "CDAB",
 "firmware": null,
 "source": {
  "title": "WM80 User Guide",
  "doc_number": "M212995EN-F",
  "revision_date": "2025-12",
  "url": "https://docs.vaisala.com/r/M212995EN-F/en-US",
  "pages": "pp. 38-39 (Modbus RTU protocol, data types), 72-80 (Appendix B registers)"
 },
 "notes": [
  "All registers are holding registers: read with function 03, write with function 16; function 43 (0x2B) reads device ID.",
  "int32 and float values are two registers in little-endian word order (least significant word first, CDAB), as the guide's data-type table states. Bytes inside each register are big-endian.",
  "Ordering option C ships as Modbus RTU, 19200 bps, N, 8, 2, address 240; the register table also lists 19200 and N82 as defaults.",
  "Left out: the analog output 1/2 settings (Tables 57-58), the diagnostic code int32 registers (reserved for Vaisala diagnostics), product order code, manufacturing date and product name."
 ],
 "registers": [
  {
   "table": "holding_register",
   "address": 0,
   "documented": "0x0000 (0)",
   "name": "Wind speed, sample",
   "description": "10 Hz sample.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 2,
   "documented": "0x0002 (2)",
   "name": "Wind direction, sample",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 4,
   "documented": "0x0004 (4)",
   "name": "Wind speed, instant",
   "description": "Moving average over the instant averaging period.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 6,
   "documented": "0x0006 (6)",
   "name": "Wind direction, instant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 8,
   "documented": "0x0008 (8)",
   "name": "Wind speed, average",
   "description": "Moving average over the statistics period.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 10,
   "documented": "0x000a (10)",
   "name": "Wind direction, average",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 12,
   "documented": "0x000c (12)",
   "name": "Wind speed, lull",
   "description": "Minimum instant speed over the statistics period.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 14,
   "documented": "0x000e (14)",
   "name": "Wind speed, gust",
   "description": "Maximum instant speed over the statistics period.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 16,
   "documented": "0x0010 (16)",
   "name": "Wind direction, lull",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 18,
   "documented": "0x0012 (18)",
   "name": "Wind direction, gust",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 20,
   "documented": "0x0014 (20)",
   "name": "Sonic temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 22,
   "documented": "0x0016 (22)",
   "name": "Wind speed U, sample",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 24,
   "documented": "0x0018 (24)",
   "name": "Wind speed V, sample",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 26,
   "documented": "0x001a (26)",
   "name": "Wind speed U, instant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 28,
   "documented": "0x001c (28)",
   "name": "Wind speed V, instant",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 30,
   "documented": "0x001e (30)",
   "name": "Wind speed U, average",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32,
   "documented": "0x0020 (32)",
   "name": "Wind speed V, average",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 512,
   "documented": "0x0200 (512)",
   "name": "Device status",
   "description": "0 = device OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "2": "Warning (W)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 515,
   "documented": "0x0203 (515)",
   "name": "Operating voltage status",
   "description": "0 = operating voltage OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "2": "Operating voltage too low (U)",
    "3": "Operating voltage too high (O)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 518,
   "documented": "0x0206 (518)",
   "name": "Heating status",
   "description": "0 = heating OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Failure (F)",
    "2": "Warning (W)",
    "3": "Information (I)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 521,
   "documented": "0x0209 (521)",
   "name": "Wind measurement status",
   "description": "0 = wind measurement OK.",
   "data_type": "BITMAP16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": {
    "0": "Measurement volume blocked (S)"
   },
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 768,
   "documented": "0x0300 (768)",
   "name": "Wind averaging method",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Scalar averaging",
    "1": "Vector averaging"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 771,
   "documented": "0x0303 (771)",
   "name": "Wind instant averaging period",
   "description": "0.1-10 s, default 3.0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 773,
   "documented": "0x0305 (773)",
   "name": "Wind statistics period",
   "description": "0.1-3600 s, default 600.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 775,
   "documented": "0x0307 (775)",
   "name": "Invalidation delay",
   "description": "0-20 s, default 4.0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 777,
   "documented": "0x0309 (777)",
   "name": "Wind direction offset",
   "description": "-180 to 180, default 0.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "deg",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 779,
   "documented": "0x030b (779)",
   "name": "Calm wind threshold",
   "description": "0.2-100, default 0.2.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "m/s",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 783,
   "documented": "0x030f (783)",
   "name": "Heating maximum current",
   "description": "0-10 A, default 10.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "A",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 785,
   "documented": "0x0311 (785)",
   "name": "Heating temperature setpoint",
   "description": "0-55 °C, default 45.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1280,
   "documented": "0x0500 (1280)",
   "name": "Heating enabled",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Disabled",
    "1": "Enabled"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1536,
   "documented": "0x0600 (1536)",
   "name": "Restart device",
   "description": "Write 1 to restart.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1538,
   "documented": "0x0602 (1538)",
   "name": "Bit rate",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "1200",
    "1": "2400",
    "2": "4800",
    "3": "9600",
    "4": "19200",
    "5": "38400",
    "6": "57600",
    "7": "115200"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1539,
   "documented": "0x0603 (1539)",
   "name": "Parity, data, stop bits",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "N81",
    "1": "N82",
    "2": "E81",
    "3": "E82",
    "4": "O81",
    "5": "O82",
    "6": "N71",
    "7": "N72",
    "8": "E71",
    "9": "E72",
    "10": "O71",
    "11": "O72"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1541,
   "documented": "0x0605 (1541)",
   "name": "Interface mode",
   "description": "",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": {
    "0": "Modbus",
    "1": "ASCII/NMEA"
   },
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 1542,
   "documented": "0x0606 (1542)",
   "name": "Modbus address",
   "description": "1-247, default 240.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7424,
   "documented": "0x1d00 (7424)",
   "name": "Vendor name",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7432,
   "documented": "0x1d08 (7432)",
   "name": "Product code",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7440,
   "documented": "0x1d10 (7440)",
   "name": "Product serial number",
   "description": "",
   "data_type": "STRING",
   "length": 8,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7680,
   "documented": "0x1e00 (7680)",
   "name": "Restore factory default settings",
   "description": "Write 1 to restore.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "RW",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7936,
   "documented": "0x1f00 (7936)",
   "name": "Signed integer test",
   "description": "Always reads -12345.",
   "data_type": "INT16",
   "length": 1,
   "word_order": null,
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 7937,
   "documented": "0x1f01 (7937)",
   "name": "Floating point test",
   "description": "Always reads -123.45.",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32768,
   "documented": "0x8000 (32768)",
   "name": "Uptime",
   "description": "",
   "data_type": "INT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "s",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32770,
   "documented": "0x8002 (32770)",
   "name": "Operating voltage",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "V",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32778,
   "documented": "0x800a (32778)",
   "name": "Heating current",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "A",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32780,
   "documented": "0x800c (32780)",
   "name": "Transducer 1 temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32782,
   "documented": "0x800e (32782)",
   "name": "Transducer 2 temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  },
  {
   "table": "holding_register",
   "address": 32784,
   "documented": "0x8010 (32784)",
   "name": "Transducer 3 temperature",
   "description": "",
   "data_type": "FLOAT32",
   "length": 2,
   "word_order": "CDAB",
   "scale": 1,
   "units": "°C",
   "access": "R",
   "values": null,
   "bits": null,
   "offset": 0
  }
 ],
 "integration": {
  "summary": "Read holding registers 0x0000-0x0015 in one request for speed, direction, gust, lull and sonic temperature as low-word-first floats, and check the status words at 0x0200-0x0209.",
  "minimum_registers": [
   {
    "table": "holding_register",
    "address": 4,
    "why": "Instant wind speed"
   },
   {
    "table": "holding_register",
    "address": 6,
    "why": "Instant wind direction"
   },
   {
    "table": "holding_register",
    "address": 8,
    "why": "Average wind speed"
   },
   {
    "table": "holding_register",
    "address": 14,
    "why": "Gust"
   },
   {
    "table": "holding_register",
    "address": 512,
    "why": "Device status"
   },
   {
    "table": "holding_register",
    "address": 521,
    "why": "Wind measurement status"
   }
  ],
  "enable": "Order the sensor with the Modbus RTU communication profile (option C), or in Vaisala Insight PC software select Communication, set Interface mode to Modbus RTU, save, then power-cycle the sensor. Interface mode is also register 0x0605.",
  "watchdog": null,
  "quirks": [
   "Floats and int32 are low word first (CDAB).",
   "Default framing is 8 data bits, no parity, 2 stop bits."
  ],
  "setup": [
   "Defaults: address 240, 19200 baud, N82.",
   "Serial defaults in the register table apply unless the ordered configuration specifies otherwise; check the configuration code with Insight if unsure.",
   "If the Modbus client runs on the same PC as Insight, close Insight first; restart the sensor after changing settings."
  ],
  "gotchas": [
   "Read the test registers 0x1F00-0x1F02 first to confirm addressing and word order."
  ]
 },
 "page": "https://easymodbus.com/modbus-register-maps/vaisala/wm80",
 "address_note": "address = 0-based Modbus wire (PDU) address; documented = as printed in the source.",
 "note": "Re-typed from the manufacturer's public documentation (see source) and verified against it. Registers vary by firmware and options; verify against the live device before writing."
}