Solar & battery inverters Modbus register maps
Updated 28 October 2026
6 solar & battery inverters register maps from 5 manufacturers: Fronius, SMA, Schneider Electric, SolarEdge, Victron Energy.
- Solar inverter
Fronius Primo GEN24 / Symo GEN24 (Plus) SunSpec int+SF
Fronius Primo/Symo GEN24 (Plus) rest-of-world variants with a battery configured, SunSpec Model Type int+SF; without a battery the MPPT model has 2 inputs and model 124 is absent.
Also known as: Primo GEN24 Plus, Symo GEN24 Plus, Primo GEN24, Symo GEN24, Symo GEN24 10.0 Plus, Primo GEN24 6.0 Plus - Solar inverter
Fronius Symo / Primo / Galvo / Symo Hybrid via Datamanager (SunSpec int+SF)
Fronius inverters read through a Fronius Datamanager (1.0/2.0 card or Hybridmanager) with SunSpec Model Type set to int+SF; model 124 present on Symo Hybrid.
Also known as: Fronius Symo, Fronius Primo, Fronius Galvo, Fronius Symo Hybrid, Fronius IG Plus, Datamanager 2.0 - Solar inverter
Schneider Electric Conext CL three-phase PV inverter 18/20/25 kVA
Conext CL (IEC, PVSCL20E/25E) and Conext CL-NA (PVSCL18NA/25NA) three-phase string inverters, map revision 1.5.
Also known as: Conext CL-NA, Conext CL-E, PVSCL18NA, PVSCL20E, PVSCL25E, PVSCL25NA - Battery inverter
SMA Sunny Tripower Storage X / Sunny Island X (SMA Modbus, ennexOS)
Sunny Tripower Storage X 30/50 (incl. US variants) and Sunny Island X 30/50 (incl. US variants), queried through the System Manager over Modbus TCP.
Also known as: STPS30-20, STPS50-20, STPS27-US-20, STPS60-US-20, SI30-20, SI50-20, SI27-US208-20, SI40-US480-20, SI60-US480-20, Sunny Tripower Storage X 50, Sunny Island X 50 - Solar inverter
SolarEdge SolarEdge inverters (SunSpec logging)
SolarEdge single-, split- and three-phase inverters with SunSpec enabled (SolarEdge Go/SetApp units, or LCD units on firmware 3.xxxx+); meter 1 at the non-Synergy default base.
Also known as: SE5000, Synergy, SolarEdge SunSpec - Battery inverter (GX gateway for inverter/chargers, batteries and solar chargers)
Victron Energy GX device Modbus-TCP (Cerbo GX, Venus GX, Color Control GX)
Victron GX devices running Venus OS with the Modbus-TCP service enabled; register list version 3.81 (document Rev 54). Core system, VE.Bus inverter/charger, battery, solar charger and ESS registers only.
Also known as: Cerbo GX, Cerbo-S GX, Venus GX, Color Control GX, CCGX, Ekrano GX, Octo GX, MultiPlus-II GX, EasySolar-II GX, Venus OS, dbus-modbustcp
Solar & battery inverters: default communication settings
Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).
| Model | Transport | Unit ID | Serial | Word order | Documented addressing | Registers |
|---|---|---|---|---|---|---|
| Primo GEN24 / Symo GEN24 (Plus) SunSpec int+SF | TCP/RTU | 1 | - | 16-bit only | 1-based | 162 |
| Symo / Primo / Galvo / Symo Hybrid via Datamanager (SunSpec int+SF) | TCP/RTU | Not stated | - | 16-bit only | 1-based | 152 |
| Conext CL three-phase PV inverter 18/20/25 kVA | RTU/TCP | 10 | 9600 baud, 8N1 | ABCD | hex 0-based | 51 |
| Sunny Tripower Storage X / Sunny Island X (SMA Modbus, ennexOS) | TCP | 3 | - | ABCD | 0-based | 30 |
| SolarEdge inverters (SunSpec logging) | RTU/TCP | 1 | 115200 baud, 8N1 | 16-bit only | 0-based | 77 |
| GX device Modbus-TCP (Cerbo GX, Venus GX, Color Control GX) | TCP | 100 | - | 16-bit only | 0-based | 128 |