Studer Innotec Modbus register maps

Updated 17 November 2026

5 Studer Innotec models, 1,182 registers in all, each re-typed from Studer Innotec’s own free documentation and checked against it.

5 of 5 shown

Studer Innotec: default communication settings

Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).

ModelTransportUnit IDSerialWord orderDocumented addressingRegisters
BSP battery status processor (via Xcom-485i)RTU618E1ABCD0-based60
VarioString MPPT solar charge controller (via Xcom-485i)RTU418E1ABCD0-based261
VarioTrack MPPT solar charge controller (via Xcom-485i)RTU218E1ABCD0-based318
Xcom-CAN in BMS mode (lithium battery link, via Xcom-485i)RTU618E1ABCD0-based74
Xtender XTH / XTM / XTS inverter-charger (via Xcom-485i)RTU118E1ABCD0-based469