Easy Modbus
  1. Home
  2. Modbus register maps
  3. Studer Innotec
  4. VarioString MPPT solar charge controller (via Xcom-485i)

Solar inverter (MPPT solar charge controller) · Modbus register map

Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) Modbus register map

Updated 17 November 2026

Short answer

VarioString is Studer's high-voltage MPPT solar charge controller for Xtender systems; the VS-120 has two PV inputs. An Xcom-485i on the Studer bus answers Modbus RTU for each VarioString. This map lists its user infos (battery, PV and PV1/PV2, production counters, state, errors) as input registers and its parameters as holding registers.

This page lists 261 Modbus registers for the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) — 174 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Studer Innotec’s own free documentation (linked below) and checked against it.

Manufacturer
Studer Innotec
Model
VarioString MPPT solar charge controller (via Xcom-485i)
Equipment type
Solar inverter (MPPT solar charge controller)
Registers
261 (174 writable)
Transport
Modbus RTU
Default unit ID
41
Default serial
8E1
Documented addressing
0-based (the number printed is the address on the wire)
32-bit word order
ABCD high word first (big-endian)
Firmware
Studer system release R706 (appendix V1.6.44); Xcom-485i protocol V1.1.3
Also known as
VS-70, VS-120, VarioString VS-120, Xcom-485i
Source document
Technical specification Studer Modbus RTU Appendix V1.6.44 (with Technical specification Studer Modbus RTU Protocol V1.1.3) · Appendix V1.6.44 (R706); Protocol V1.1.3 · rev. 2025-09-03
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i)

Integration in brief

Fit an Xcom-485i on the Studer communication bus and poll it as a Modbus RTU slave. Each Studer device answers at its own unit ID (offset set by DIP switches 1-2); read infos with function 04 and parameters with 03, always 2 registers at a time, and decode as big-endian float.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 0Battery voltage {15000}FLOAT32 ABCDBattery voltageRead
IR 2Battery current {15001}FLOAT32 ABCDBattery currentRead
IR 8PV voltage {15004}FLOAT32 ABCDPV voltageRead
IR 20PV power {15010}FLOAT32 ABCDPV powerRead
IR 34Production PV in (kWh) for the current day {15017}FLOAT32 ABCDEnergy produced todayRead
IR 46Total PV produced energy {15023}FLOAT32 ABCDTotal produced energyRead
IR 26PV operating mode {15013}FLOAT32 ABCDPV operating modeRead
IR 98Type of error {15049}FLOAT32 ABCDType of errorRead

Enable Modbus control & writes

Install the Xcom-485i on the Studer bus. DIP switches 1-2 set the unit-ID offset (0, 32, 64 or 128) and switches 7-8 set the baud rate (9600, 19200, 38400 or 115200). Frames are 8 data bits, even parity, 1 stop bit.

Byte order & addressing

Network setup

Watch out for

Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

261 of 261 shown
Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR0Battery voltage {15000}FLOAT32ABCDVRead
IR2Battery current {15001}FLOAT32ABCDARead
IR4Battery cycle phase {15002}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Bulk; 1 = Absorpt.; 2 = Equalize; 3 = Floating; 6 = R.float.; 7 = Per.abs.
IR6PV type of wiring {15003}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Unknown; 1 = Independ.; 2 = Series; 3 = Parallel; 4 = Error
IR8PV voltage {15004}FLOAT32ABCDVRead
IR10PV1 voltage {15005}FLOAT32ABCDVRead
IR12PV2 voltage {15006}FLOAT32ABCDVRead
IR14PV current {15007}FLOAT32ABCDARead
IR16PV1 current {15008}FLOAT32ABCDARead
IR18PV2 current {15009}FLOAT32ABCDARead
IR20PV power {15010}FLOAT32ABCDkWRead
IR22PV1 power {15011}FLOAT32ABCDkWRead
IR24PV2 power {15012}FLOAT32ABCDkWRead
IR26PV operating mode {15013}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Night; 1 = Security; 2 = OFF; 3 = Charge; 4 = ChargeV; 5 = Charge I; 6 = ChargeP; 7 = ChargeIpv; 8 = ChargeT; 10 = Ch.Ibsp
IR28PV1 operating mode {15014}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Night; 1 = Security; 2 = OFF; 3 = Charge; 4 = ChargeV; 5 = Charge I; 6 = ChargeP; 7 = ChargeIpv; 8 = ChargeT; 10 = Ch.Ibsp
IR30PV2 operating mode {15015}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Night; 1 = Security; 2 = OFF; 3 = Charge; 4 = ChargeV; 5 = Charge I; 6 = ChargeP; 7 = ChargeIpv; 8 = ChargeT; 10 = Ch.Ibsp
IR32Production PV in (Ah) for the current day {15016}FLOAT32ABCDAhRead
IR34Production PV in (kWh) for the current day {15017}FLOAT32ABCDkWhRead
IR36Production PV1 in (kWh) for the current day {15018}FLOAT32ABCDkWhRead
IR38Production PV2 in (kWh) for the current day {15019}FLOAT32ABCDkWhRead
IR40Produced PV energy resettable counter {15020}FLOAT32ABCDkWhRead
IR42Produced PV1 energy resettable counter {15021}FLOAT32ABCDkWhRead
IR44Produced PV2 energy resettable counter {15022}FLOAT32ABCDkWhRead
IR46Total PV produced energy {15023}FLOAT32ABCDMWhRead
IR48Total PV1 produced energy {15024}FLOAT32ABCDMWhRead
IR50Total PV2 produced energy {15025}FLOAT32ABCDMWhRead
IR52Production PV in (Ah) for the previous day {15026}FLOAT32ABCDAhRead
IR54Production PV in (Wh) for the previous day {15027}FLOAT32ABCDkWhRead
IR56Production PV1 in (Wh) for the previous day {15028}FLOAT32ABCDkWhRead
IR58Production PV2 in (Wh) for the previous day {15029}FLOAT32ABCDkWhRead
IR60Number of irradiation hours for the current day {15030}FLOAT32ABCDhRead
IR62Number of irradiation hours for the previous day {15031}FLOAT32ABCDhRead
IR64Battery temperature {15032}FLOAT32ABCD°CRead
IR66Max PV voltage for the current day {15033}FLOAT32ABCDVRead
IR68Max PV1 voltage for the current day {15034}FLOAT32ABCDVRead
IR70Max PV2 voltage for the current day {15035}FLOAT32ABCDVRead
IR72Max battery current of the current day {15036}FLOAT32ABCDARead
IR74Max PV power for the current day {15037}FLOAT32ABCDkWRead
IR76Max PV1 power for the current day {15038}FLOAT32ABCDkWRead
IR78Max PV2 power for the current day {15039}FLOAT32ABCDkWRead
IR80Max battery voltage for the current day {15040}FLOAT32ABCDVRead
IR82Min battery voltage for the current day {15041}FLOAT32ABCDVRead
IR84Time in absorption of the current day {15042}FLOAT32ABCDhRead
IR86BAT- and Earth voltage {15043}FLOAT32ABCDVRead
IR88PV- and Earth voltage {15044}FLOAT32ABCDVRead
IR90PV1- and Earth voltage {15045}FLOAT32ABCDVRead
IR92PV2- and Earth voltage {15046}FLOAT32ABCDVRead
IR98Type of error {15049}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = None; 1 = OverV_B; 2 = OverV_PV; 3 = OverV_PV1; 4 = OverV_PV2; 5 = OverI_PV; 6 = OverI_PV1; 7 = OverI_PV2; 8 = GroundBat; 9 = GroundPV; 10 = GroundPV1; 11 = GroundPV2; 12 = OverTemp; 13 = UnderV_B; 14 = Cabling; 15 = Other
IR100Synchronized with Xtender battery cycle {15050}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = No; 1 = Yes
IR102Synchronisation state {15051}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead4 = XTslave; 5 = VTslave; 8 = VTmaster; 9 = Autonom; 10 = VSslave; 11 = VSmaster
IR104Number of days before next equalization {15052}FLOAT32ABCDdaysRead
IR106Battery set point {15053}FLOAT32ABCDVRead
IR108Battery voltage (minute avg) {15054}FLOAT32ABCDVRead
IR110Battery voltage (minute max) {15055}FLOAT32ABCDVRead
IR112Battery voltage (minute min) {15056}FLOAT32ABCDVRead
IR114Battery current (minute avg) {15057}FLOAT32ABCDARead
IR116PV voltage (minute avg) {15058}FLOAT32ABCDVRead
IR118PV1 voltage (minute avg) {15059}FLOAT32ABCDVRead
IR120PV2 voltage (minute avg) {15060}FLOAT32ABCDVRead
IR122PV power (minute avg) {15061}FLOAT32ABCDkWRead
IR124PV1 power (minute avg) {15062}FLOAT32ABCDkWRead
IR126PV2 power (minute avg) {15063}FLOAT32ABCDkWRead
IR128Battery temperature (minute avg) {15064}FLOAT32ABCD°CRead
IR130Electronic temperature 1 (minute avg) {15065}FLOAT32ABCD°CRead
IR132Electronic temperature 1 (minute max) {15066}FLOAT32ABCD°CRead
IR134Electronic temperature 1 (minute min) {15067}FLOAT32ABCD°CRead
IR136Electronic temperature 2 (minute avg) {15068}FLOAT32ABCD°CRead
IR138Electronic temperature 2 (minute max) {15069}FLOAT32ABCD°CRead
IR140Electronic temperature 2 (minute min) {15070}FLOAT32ABCD°CRead
IR142Number of parameters (in code) {15071}FLOAT32ABCDRead
IR144Number of parameters (in flash) {15072}FLOAT32ABCDRead
IR146Number of infos users {15073}FLOAT32ABCDRead
IR148ID type {15074}FLOAT32ABCDRead
IR150ID bat voltage {15075}FLOAT32ABCDVRead
IR152ID HW {15076}FLOAT32ABCDRead
IR154ID SOFT msb {15077}Software version word, encoded as in the protocol spec's version section.FLOAT32ABCDRead
IR156ID SOFT lsb {15078}Software version word, encoded as in the protocol spec's version section.FLOAT32ABCDRead
IR158ID SID {15079}FLOAT32ABCDRead
IR176State of auxiliary Aux 1 {15088}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Opened; 1 = Closed
IR178State of auxiliary Aux 2 {15089}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Opened; 1 = Closed
IR180Relay Aux 1 mode {15090}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead1 = A; 2 = I; 3 = M; 4 = M
IR182Relay Aux 2 mode {15091}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead1 = A; 2 = I; 3 = M; 4 = M
IR204ID FID msb {15102}Half of the unit's unique FID number.FLOAT32ABCDRead
IR206ID FID lsb {15103}Half of the unit's unique FID number.FLOAT32ABCDRead
IR216State of the VarioString {15108}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = Off; 1 = On
IR218Local daily communication error counter (CAN) {15109}FLOAT32ABCDRead
IR222Remote entry state {15111}Enumerated state, sent as a float (1.0 = code 1).FLOAT32ABCDRead0 = RM EN 0; 1 = RM EN 1
HR2Battery charge current (VS-120) {14001}Expert level. Range 0 to 120, default 120.FLOAT32ABCDAdcRead/write
HR4Configuration of PV modules (VS-120) {14002}Basic level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = Automatic; 2 = Independent; 4 = Serial; 8 = Parallel
HR10Floating voltage {14005}Expert level. Range 37.9 to 68.2, default 54.4.FLOAT32ABCDVdcRead/write
HR12Force phase of floating {14006}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR16Absorption phase allowed {14008}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR18Absorption voltage {14009}Expert level. Range 37.9 to 68.2, default 57.6.FLOAT32ABCDVdcRead/write
HR20Force absorption phase {14010}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR22Absorption duration {14011}Expert level. Range 5 to 510, default 120.FLOAT32ABCDminRead/write
HR24End of absorption triggered by the current {14012}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR26Current threshold to end absorption phase {14013}Expert level. Range 2 to 120, default 10.FLOAT32ABCDAdcRead/write
HR34Equalization allowed {14017}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR36Force equalization {14018}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR38Equalization before absorption phase {14019}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR40Equalization current {14020}Expert level. Range 2 to 120, default 80.FLOAT32ABCDAdcRead/write
HR42Equalization voltage {14021}Expert level. Range 52.1 to 68.2, default 62.4.FLOAT32ABCDVdcRead/write
HR44Equalization duration {14022}Expert level. Range 5 to 510, default 30.FLOAT32ABCDminRead/write
HR46Equalization with fixed interval {14023}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR48Days between equalizations {14024}Expert level. Range 1 to 365, default 26.FLOAT32ABCDdaysRead/write
HR50End of equalization triggered by the current {14025}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR52Current threshold to end equalization phase {14026}Expert level. Range 4 to 30, default 10.FLOAT32ABCDAdcRead/write
HR56Force a new cycle {14028}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR58Voltage level 1 to start a new cycle {14029}Expert level. Range 37.9 to 68.2, default 48.8.FLOAT32ABCDVdcRead/write
HR60Time period under voltage level 1 to start a new cycle {14030}Expert level. Range 0 to 240, default 30.FLOAT32ABCDminRead/write
HR62Voltage level 2 to start a new cycle {14031}Expert level. Range 37.9 to 68.2, default 47.2.FLOAT32ABCDVdcRead/write
HR64Time period under voltage level 2 to start a new cycle {14032}Expert level. Range 0 to 240, default 2.FLOAT32ABCDminRead/write
HR66Cycling restricted {14033}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR68Minimal delay between cycles {14034}Expert level. Range 0 to 540, default 1.FLOAT32ABCDhoursRead/write
HR70Temperature compensation {14035}Expert level. Range -8 to 0, default -3.FLOAT32ABCDmV/°C/cellRead/write
HR72Synchronisation battery cycle with Xtender {14036}Basic level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR76ON of the VarioString {14038}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR78OFF of the VarioString {14039}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR80Type of battery grounding {14040}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = No control; 2 = Bat+ grounded; 4 = Bat- grounded; 8 = Bat floating
HR82Type of PV grounding {14041}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = No control; 2 = PV+ grounded; 4 = PV- grounded; 8 = PV floating
HR84Type of PV2 grounding {14042}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = No control; 2 = PV+ grounded; 4 = PV- grounded; 8 = PV floating
HR86Type of MPP tracking algorithm PV {14043}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = P&O; 2 = OC ratio; 4 = Upv fixed; 8 = LSF
HR88PV voltage fixed (for PV in series) {14044}Expert level. Range 200 to 900, default 700.FLOAT32ABCDVdcRead/write
HR90Ratio of PV open circuit voltage {14045}Expert level. Range 0.5 to 1, default 0.7.FLOAT32ABCDRead/write
HR92Type of MPP tracking algorithm PV2 {14046}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = P&O; 2 = OC ratio; 4 = Upv fixed; 8 = LSF
HR94PV2 voltage fixed {14047}Expert level. Range 100 to 600, default 500.FLOAT32ABCDVdcRead/write
HR96Ratio of PV2 open circuit voltage {14048}Expert level. Range 0.5 to 1, default 0.7.FLOAT32ABCDRead/write
HR102Reset daily solar production meters {14051}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR104Reset daily min-max {14052}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR118Reset of all VarioString {14059}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR130Battery overvoltage level {14065}Expert level. Range 37.9 to 68.2, default 68.2.FLOAT32ABCDVdcRead/write
HR132Restart voltage level after a battery overvoltage {14066}Expert level. Range 37.9 to 68.2, default 64.8.FLOAT32ABCDVdcRead/write
HR134Restore default settings {14067}Basic level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR136Restore factory settings {14068}Installer level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR138Parameters saved in flash memory {14069}Installer level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR142Operating mode (AUX 1) {14071}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = Automatic; 2 = Reversed automatic; 4 = Manual ON; 8 = Manual OFF
HR144Combination of the events for the auxiliary contact (AUX 1) {14072}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write0 = Any (Function OR); 1 = All (Function AND)
HR148Activated in night mode (AUX 1) {14074}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR150Delay of activation after entering night mode (AUX 1) {14075}Expert level. Range 0 to 1440, default 1.FLOAT32ABCDminRead/write
HR152Activation time for the auxiliary relay in night mode (AUX 1) {14076}Expert level. Range 0 to 1440, default 1.FLOAT32ABCDminRead/write
HR156VarioString is OFF (AUX 1) {14078}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR158Battery undervoltage (AUX 1) {14079}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR160Battery overvoltage (AUX 1) {14080}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR162Earth fault (AUX 1) {14081}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR164PV error (48h without charge) (AUX 1) {14082}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR166Overtemperature (AUX 1) {14083}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR168Bulk charge phase (AUX 1) {14084}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR170Absorption phase (AUX 1) {14085}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR172Equalization phase (AUX 1) {14086}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR174Floating (AUX 1) {14087}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR176Reduced floating (AUX 1) {14088}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR178Periodic absorption (AUX 1) {14089}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR182Battery voltage 1 activate (AUX 1) {14091}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR184Battery voltage 1 (AUX 1) {14092}Expert level. Range 36 to 72, default 46.8.FLOAT32ABCDVdcRead/write
HR186Delay 1 (AUX 1) {14093}Expert level. Range 0 to 60, default 1.FLOAT32ABCDminRead/write
HR188Battery voltage 2 activate (AUX 1) {14094}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR190Battery voltage 2 (AUX 1) {14095}Expert level. Range 36 to 72, default 47.8.FLOAT32ABCDVdcRead/write
HR192Delay 2 (AUX 1) {14096}Expert level. Range 0 to 60, default 10.FLOAT32ABCDminRead/write
HR194Battery voltage 3 activate (AUX 1) {14097}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR196Battery voltage 3 (AUX 1) {14098}Expert level. Range 36 to 72, default 48.5.FLOAT32ABCDVdcRead/write
HR198Delay 3 (AUX 1) {14099}Expert level. Range 0 to 60, default 60.FLOAT32ABCDminRead/write
HR200Battery voltage to deactivate (AUX 1) {14100}Expert level. Range 36 to 72, default 54.FLOAT32ABCDVdcRead/write
HR202Delay to deactivate (AUX 1) {14101}Expert level. Range 0 to 480, default 60.FLOAT32ABCDminRead/write
HR204Deactivate if battery in floating phase (AUX 1) {14102}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR208Contact activated with the temperature of battery (AUX 1) {14104}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR210Contact activated over (AUX 1) {14105}Expert level. Range -10 to 50, default 3.FLOAT32ABCD°CRead/write
HR212Contact deactivated below (AUX 1) {14106}Expert level. Range -10 to 50, default 5.FLOAT32ABCD°CRead/write
HR214Only activated if the battery is not in bulk phase (AUX 1) {14107}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR218Contact activated with the SOC 1 of battery (AUX 1) {14109}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR220Contact activated below SOC 1 (AUX 1) {14110}Expert level. Range 0 to 100, default 50.FLOAT32ABCD% SOCRead/write
HR222Delay 1 (AUX 1) {14111}Expert level. Range 0 to 99, default 12.FLOAT32ABCDhoursRead/write
HR224Contact activated with the SOC 2 of battery (AUX 1) {14112}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR226Contact activated below SOC 2 (AUX 1) {14113}Expert level. Range 0 to 100, default 30.FLOAT32ABCD%Read/write
HR228Delay 2 (AUX 1) {14114}Expert level. Range 0 to 99, default 0.2.FLOAT32ABCDhoursRead/write
HR230Contact activated with the SOC 3 of battery (AUX 1) {14115}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR232Contact activated below SOC 3 (AUX 1) {14116}Expert level. Range 0 to 100, default 20.FLOAT32ABCD%Read/write
HR234Delay 3 (AUX 1) {14117}Expert level. Range 0 to 99, default 0.FLOAT32ABCDhoursRead/write
HR236Contact deactivated over SOC (AUX 1) {14118}Expert level. Range 0 to 100, default 90.FLOAT32ABCD% SOCRead/write
HR238Delay to deactivate (AUX 1) {14119}Expert level. Range 0 to 10, default 0.2.FLOAT32ABCDhoursRead/write
HR240Deactivate if battery in floating phase (AUX 1) {14120}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR242Reset all settings (AUX 1) {14121}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR246Operating mode (AUX 2) {14123}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = Automatic; 2 = Reversed automatic; 4 = Manual ON; 8 = Manual OFF
HR248Combination of the events for the auxiliary contact (AUX 2) {14124}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write0 = Any (Function OR); 1 = All (Function AND)
HR252Activated in night mode (AUX 2) {14126}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR254Delay of activation after entering night mode (AUX 2) {14127}Expert level. Range 0 to 1440, default 1.FLOAT32ABCDminRead/write
HR256Activation time for the auxiliary relay in night mode (AUX 2) {14128}Expert level. Range 0 to 1440, default 1.FLOAT32ABCDminRead/write
HR260VarioString is OFF (AUX 2) {14130}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR262Battery undervoltage (AUX 2) {14131}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR264Battery overvoltage (AUX 2) {14132}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR266Earth fault (AUX 2) {14133}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR268PV error (48h without charge) (AUX 2) {14134}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR270Overtemperature (AUX 2) {14135}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR272Bulk charge phase (AUX 2) {14136}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR274Absorption phase (AUX 2) {14137}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR276Equalization phase (AUX 2) {14138}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR278Floating (AUX 2) {14139}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR280Reduced floating (AUX 2) {14140}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR282Periodic absorption (AUX 2) {14141}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR286Battery voltage 1 activate (AUX 2) {14143}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR288Battery voltage 1 (AUX 2) {14144}Expert level. Range 36 to 72, default 46.8.FLOAT32ABCDVdcRead/write
HR290Delay 1 (AUX 2) {14145}Expert level. Range 0 to 60, default 1.FLOAT32ABCDminRead/write
HR292Battery voltage 2 activate (AUX 2) {14146}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR294Battery voltage 2 (AUX 2) {14147}Expert level. Range 36 to 72, default 47.8.FLOAT32ABCDVdcRead/write
HR296Delay 2 (AUX 2) {14148}Expert level. Range 0 to 60, default 10.FLOAT32ABCDminRead/write
HR298Battery voltage 3 activate (AUX 2) {14149}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR300Battery voltage 3 (AUX 2) {14150}Expert level. Range 36 to 72, default 48.5.FLOAT32ABCDVdcRead/write
HR302Delay 3 (AUX 2) {14151}Expert level. Range 0 to 60, default 60.FLOAT32ABCDminRead/write
HR304Battery voltage to deactivate (AUX 2) {14152}Expert level. Range 36 to 72, default 54.FLOAT32ABCDVdcRead/write
HR306Delay to deactivate (AUX 2) {14153}Expert level. Range 0 to 480, default 60.FLOAT32ABCDminRead/write
HR308Deactivate if battery in floating phase (AUX 2) {14154}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR312Contact activated with the temperature of battery (AUX 2) {14156}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR314Contact activated over (AUX 2) {14157}Expert level. Range -10 to 50, default 3.FLOAT32ABCD°CRead/write
HR316Contact deactivated below (AUX 2) {14158}Expert level. Range -10 to 50, default 5.FLOAT32ABCD°CRead/write
HR318Only activated if the battery is not in bulk phase (AUX 2) {14159}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR322Contact activated with the SOC 1 of battery (AUX 2) {14161}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR324Contact activated below SOC 1 (AUX 2) {14162}Expert level. Range 0 to 100, default 50.FLOAT32ABCD% SOCRead/write
HR326Delay 1 (AUX 2) {14163}Expert level. Range 0 to 99, default 12.FLOAT32ABCDhoursRead/write
HR328Contact activated with the SOC 2 of battery (AUX 2) {14164}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR330Contact activated below SOC 2 (AUX 2) {14165}Expert level. Range 0 to 100, default 30.FLOAT32ABCD%Read/write
HR332Delay 2 (AUX 2) {14166}Expert level. Range 0 to 99, default 0.2.FLOAT32ABCDhoursRead/write
HR334Contact activated with the SOC 3 of battery (AUX 2) {14167}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR336Contact activated below SOC 3 (AUX 2) {14168}Expert level. Range 0 to 100, default 20.FLOAT32ABCD%Read/write
HR338Delay 3 (AUX 2) {14169}Expert level. Range 0 to 99, default 0.FLOAT32ABCDhoursRead/write
HR340Contact deactivated over SOC (AUX 2) {14170}Expert level. Range 0 to 100, default 90.FLOAT32ABCD% SOCRead/write
HR342Delay to deactivate (AUX 2) {14171}Expert level. Range 0 to 10, default 0.2.FLOAT32ABCDhoursRead/write
HR344Deactivate if battery in floating phase (AUX 2) {14172}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR346Reset all settings (AUX 2) {14173}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR348Block manual programming (dip-switch) {14174}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR350Type of PV1 grounding {14175}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = No control; 2 = PV+ grounded; 4 = PV- grounded; 8 = PV floating
HR352Type of MPP tracking algorithm PV1 {14176}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = P&O; 2 = OC ratio; 4 = Upv fixed; 8 = LSF
HR354PV1 voltage fixed {14177}Expert level. Range 100 to 600, default 500.FLOAT32ABCDVdcRead/write
HR356Ratio of PV1 open circuit voltage {14178}Expert level. Range 0.5 to 1, default 0.7.FLOAT32ABCDRead/write
HR358PV voltage fixed (for PV in //) {14179}Expert level. Range 100 to 600, default 500.FLOAT32ABCDVdcRead/write
HR364Reset PV energy meter {14182}Expert level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR366Reset total produced PV energy meter {14183}Qualified service level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR376VarioString is ON (AUX 1) {14188}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR378VarioString is ON (AUX 2) {14189}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR380PV wiring type erased from memory {14190}Installer level. Write 1.0 to trigger.FLOAT32ABCDWrite
HR384Establishment time (Algo MPPT) {14192}Installer level. Range 0 to 300, default 0.FLOAT32ABCDsecRead/write
HR386Averaging time (Algo MPPT) {14193}Installer level. Range 0 to 300, default 0.FLOAT32ABCDsecRead/write
HR392Type of PV grounding {14196}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = No control; 2 = PV+ grounded; 4 = PV- grounded; 8 = PV floating
HR394Type of MPP tracking algorithm PV {14197}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = P&O; 2 = OC ratio; 4 = Upv fixed; 8 = LSF
HR396PV voltage fixed {14198}Expert level. Range 100 to 600, default 500.FLOAT32ABCDVdcRead/write
HR398Ratio of PV open circuit voltage {14199}Expert level. Range 0.5 to 1, default 0.7.FLOAT32ABCDRead/write
HR402Remote entry active {14201}Expert level. Option code as a float; one option at a time.FLOAT32ABCDRead/write1 = Closed; 2 = Open; 4 = Edge
HR404ON/OFF command {14202}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR406Activated by AUX1 state {14203}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR408Start equalization {14204}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR410Send a message when remote entry changes state {14205}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR414Contact activated with fixed time schedule (AUX 1) {14207}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR416Start hour (AUX 1) {14208}Expert level. Minutes after midnight as a float (0-1440).FLOAT32ABCDminRead/write
HR418End hour (AUX 1) {14209}Expert level. Minutes after midnight as a float (0-1440).FLOAT32ABCDminRead/write
HR422Contact activated with fixed time schedule (AUX 2) {14211}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR424Start hour (AUX 2) {14212}Expert level. Minutes after midnight as a float (0-1440).FLOAT32ABCDminRead/write
HR426End hour (AUX 2) {14213}Expert level. Minutes after midnight as a float (0-1440).FLOAT32ABCDminRead/write
HR428Remote entry (AUX 1) {14214}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR430Remote entry (AUX 2) {14215}Expert level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR432Battery undervoltage {14216}Expert level. Range 34 to 68.2, default 40.FLOAT32ABCDVdcRead/write
HR434Battery charge current (VS-70) {14217}Expert level. Range 0 to 70, default 70.FLOAT32ABCDAdcRead/write
HR436VarioString watchdog enabled (SCOM) {14218}Installer level. Float 0.0 = no, 1.0 = yes.FLOAT32ABCDRead/write0 = No; 1 = Yes
HR438VarioString watchdog delay (SCOM) {14219}Installer level. Range 10 to 300, default 60.FLOAT32ABCDsecRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i)

What Modbus registers does the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) have?

This map lists 261 registers: 87 input registers, 174 holding registers. 174 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers 0-based (the number printed is the address on the wire). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The appendix lists the register exactly as it goes in the request. The protocol spec's example reads info 3001 from register 2 with start address 0x0002 in the frame, and parameter 1107 from register 14 (0x000E).

What byte order does the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i)?

Start with IR 0 Battery voltage {15000} (Battery voltage); IR 2 Battery current {15001} (Battery current); IR 8 PV voltage {15004} (PV voltage); IR 20 PV power {15010} (PV power); IR 34 Production PV in (kWh) for the current day {15017} (Energy produced today); IR 46 Total PV produced energy {15023} (Total produced energy); IR 26 PV operating mode {15013} (PV operating mode); IR 98 Type of error {15049} (Type of error).

How do I enable Modbus control of the Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i)?

Install the Xcom-485i on the Studer bus. DIP switches 1-2 set the unit-ID offset (0, 32, 64 or 128) and switches 7-8 set the baud rate (9600, 19200, 38400 or 115200). Frames are 8 data bits, even parity, 1 stop bit.

Where is the official Studer Innotec VarioString MPPT solar charge controller (via Xcom-485i) Modbus documentation?

The source is Technical specification Studer Modbus RTU Appendix V1.6.44 (with Technical specification Studer Modbus RTU Protocol V1.1.3) (Appendix V1.6.44 (R706); Protocol V1.1.3), revision 2025-09-03, published free by Studer Innotec at https://studer-innotec.com/wp-content/uploads/2025/09/Manuel-xcom-485i-technical-specification.zip.

More Studer Innotec Modbus register maps

Other solar & battery inverters register maps

All solar & battery inverters Modbus register maps →

Source: Technical specification Studer Modbus RTU Appendix V1.6.44 (with Technical specification Studer Modbus RTU Protocol V1.1.3) · Appendix V1.6.44 (R706); Protocol V1.1.3 · rev. 2025-09-03. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.