Teledyne Detcon Modbus register maps
Updated 17 November 2026
8 Teledyne Detcon models, 172 registers in all, each re-typed from Teledyne Detcon’s own free documentation and checked against it.
- Sensor (fixed gas detector)
Teledyne Detcon Model CX-IR infrared combustible gas sensor (Modbus RTU)
Teledyne Detcon CX-IR wired infrared gas sensors (RS-485 Modbus RTU and 4-20 mA), instruction manual Document #4428 Rev. 1.9.
Also known as: CX-IR, Detcon CX-IR - Sensor (fixed gas detector)
Teledyne Detcon Model DM-700 electrochemical toxic gas / oxygen sensor (RS-485 Modbus)
Teledyne Detcon DM-700 smart sensors with the 4-20 mA and RS-485 Modbus outputs, instruction manual Document #3207, Rev. 5.9.
Also known as: DM-700, Detcon DM-700, Teledyne Detcon DM-700 - Sensor (fixed gas detector)
Teledyne Detcon Model FP-624D MicroSafe combustible gas sensor (RS-485 Modbus)
Teledyne Detcon FP-624D MicroSafe catalytic LEL sensor with 4-20 mA, relays and RS-485 Modbus RTU, instruction manual Document #3598 Rev. 1.7.
Also known as: FP-624D, MicroSafe FP-624D, Detcon FP-624D - Sensor (fixed gas detector)
Teledyne Detcon Model FP-700 catalytic bead combustible gas sensor (RS-485 Modbus)
Teledyne Detcon FP-700 smart sensors with the 4-20 mA and RS-485 Modbus outputs, instruction manual Document #3168, Rev. 5.7.
Also known as: FP-700, Detcon FP-700, Teledyne Detcon FP-700 - Sensor (fixed gas detector)
Teledyne Detcon Model IR-700 infrared combustible / CO2 gas sensor (RS-485 Modbus)
Teledyne Detcon IR-700 smart sensors with the 4-20 mA and RS-485 Modbus outputs, instruction manual Document #3169, Rev. 4.9.
Also known as: IR-700, Detcon IR-700, Teledyne Detcon IR-700 - Sensor (fixed gas detector)
Teledyne Detcon Model PI-700 photoionization (PID) VOC sensor (RS-485 Modbus)
Teledyne Detcon PI-700 smart sensors with the 4-20 mA and RS-485 Modbus outputs, instruction manual Document #3228, Rev. 4.0.
Also known as: PI-700, Detcon PI-700, Teledyne Detcon PI-700 - Sensor (fixed gas detector)
Teledyne Detcon Model TP-700 MOS (metal oxide) H2S sensor (RS-485 Modbus)
Teledyne Detcon TP-700 smart sensors with the 4-20 mA and RS-485 Modbus outputs, instruction manual Document #3150, Rev. 4.6.
Also known as: TP-700, Detcon TP-700, Teledyne Detcon TP-700 - Sensor controller (gas detection)
Teledyne Detcon Model X40 integrated alarm and control system (Modbus slave port)
Teledyne Detcon X40 gas detection controllers (8 and 32 channel, N4X and N1P enclosures), instruction manual Document #3672 Rev. 3.8, slave port register map.
Also known as: X40-08-N4X, X40-32-N4X, X40-32-N1P, X40 controller
Teledyne Detcon: default communication settings
Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).
| Model | Transport | Unit ID | Serial | Word order | Documented addressing | Registers |
|---|---|---|---|---|---|---|
| Model CX-IR infrared combustible gas sensor (Modbus RTU) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 16 |
| Model DM-700 electrochemical toxic gas / oxygen sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 16 |
| Model FP-624D MicroSafe combustible gas sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 13 |
| Model FP-700 catalytic bead combustible gas sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 16 |
| Model IR-700 infrared combustible / CO2 gas sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 16 |
| Model PI-700 photoionization (PID) VOC sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 16 |
| Model TP-700 MOS (metal oxide) H2S sensor (RS-485 Modbus) | RTU | 1 | 9600 baud, 8N1 | 16-bit only | 0-based | 15 |
| Model X40 integrated alarm and control system (Modbus slave port) | RTU | Not stated | 9600 baud, 8N1 | 16-bit only | 0-based | 64 |