- Home
- Modbus register maps
- Morningstar
Manufacturer
Morningstar Modbus register maps
Updated 17 November 2026
4 Morningstar models, 177 registers in all, each re-typed from Morningstar’s own free documentation and checked against it.
- Solar charge controller (PWM, dual battery)
Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)
Morningstar SunSaver Duo through the MSC MeterBus-to-RS-232 adapter; Modbus specification V04 (19 March 2019). 16-bit registers only.
Also known as: SunSaver Duo, SSDuo - Solar charge controller (MPPT, battery charger)
Morningstar SunSaver MPPT solar charge controller (Modbus RTU via MeterBus)
Morningstar SunSaver MPPT through the MSC MeterBus-to-RS-232 adapter; Modbus specification v11.
Also known as: SunSaver MPPT, SS-MPPT - Battery inverter (off-grid sine wave)
Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)
Morningstar SureSine-300 (115 V and 220 V versions) via the MSC MeterBus adapter; Modbus specification V03 (29 Oct 2008).
Also known as: SureSine, SureSine-300 - Solar charge controller (PWM charge / load / diversion)
Morningstar TriStar TS-45 / TS-60 PWM charge, load and diversion controller (Modbus RTU)
Morningstar TriStar TS-45 and TS-60 (non-MPPT) on the RS-232 port; Modbus specification V07 (31 Jan 2020).
Also known as: TS-45, TS-60, TriStar, TriStar PWM
Morningstar: default communication settings
Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).
| Model | Transport | Unit ID | Serial | Word order | Documented addressing | Registers |
|---|---|---|---|---|---|---|
| SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) | RTU | 1 | 9600 baud, 8N2 | 16-bit only | hex 0-based | 52 |
| SunSaver MPPT solar charge controller (Modbus RTU via MeterBus) | RTU | 1 | 9600 baud, 8N2 | CDAB | hex 0-based | 56 |
| SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) | RTU | 1 | 9600 baud, 8N2 | 16-bit only | hex 0-based | 24 |
| TriStar TS-45 / TS-60 PWM charge, load and diversion controller (Modbus RTU) | RTU | 1 | 9600 baud, 8N2 | ABCD | hex 0-based | 45 |