Solar charge controller (PWM, dual battery) · Modbus register map

Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) Modbus register map

Updated 17 November 2026

Short answer

The SunSaver Duo is a PWM solar charge controller that charges two separate batteries. Via its RJ-11 MeterBus port and Morningstar's MSC adapter it speaks Modbus RTU: both battery voltages and charge currents, solar voltage, duty cycles, charge setpoints in use, state and fault bits, plus EEPROM custom settings and a few coils.

This page lists 52 Modbus registers for the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) — 14 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Morningstar’s own free documentation (linked below) and checked against it.

Manufacturer
Morningstar
Model
SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)
Equipment type
Solar charge controller (PWM, dual battery)
Registers
52 (14 writable)
Transport
Modbus RTU
Default unit ID
1
Default serial
9600 baud, 8N2
Documented addressing
hexadecimal, 0-based
Also known as
SunSaver Duo, SSDuo
Source document
SunSaver Duo MODBUS Specification · V04 · rev. 2019-03-19
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)

Integration in brief

Through the MSC adapter at 9600 8N2, ID 1, read 0x0000-0x0010 for both battery voltages, solar voltage and charge currents, and 0x0108-0x0110 for state, faults and battery states.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 0vb1 - battery 1 voltageUINT16Battery 1 voltageRead
HR 1vb2 - battery 2 voltageUINT16Battery 2 voltageRead
HR 3ia1 - charge current battery 1UINT16Charge current battery 1Read
HR 4ia2 - charge current battery 2UINT16Charge current battery 2Read
HR 264state - controller stateUINT16Controller stateRead
HR 265faults - fault bitfieldBITMAP16Fault bitfieldRead

Enable Modbus control & writes

The meter port auto-detects Meterbus or Modbus; connect the MSC adapter and poll. Coil 0x00F1 switches the port back to Meterbus for a remote meter.

Byte order & addressing

Network setup

Watch out for

Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

52 of 52 shown
Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
CO20doc 0x0014Clear faultsSome faults need 30 s before they can be cleared.BITWrite
CO22doc 0x0016Force EEPROM updateWrites RAM values to EEPROM.BITWrite
CO23doc 0x0017Reset min/max volts and ampsSet only; reads 0.BITWrite
CO241doc 0x00F1Switch to Meterbus protocolHands the port back to the Morningstar remote meter protocol.BITWrite
CO255doc 0x00FFReset controllerReboots the controller software.BITWrite
HR0doc 0x0000vb1 - battery 1 voltageFiltered (about 2.5 s).UINT16× 0.0005555556VRead
HR1doc 0x0001vb2 - battery 2 voltageUINT16× 0.0005555556VRead
HR2doc 0x0002va - solar voltageUINT16× 0.0009689922VRead
HR3doc 0x0003ia1 - charge current battery 1UINT16× 0.0014858841ARead
HR4doc 0x0004ia2 - charge current battery 2UINT16× 0.0014858841ARead
HR8doc 0x0008vref1 - charge reference battery 1Temperature-compensated target voltage.UINT16× 0.0005555556VRead
HR9doc 0x0009vref2 - charge reference battery 2UINT16× 0.0005555556VRead
HR10doc 0x000Adutcyc1 - PWM duty battery 10-417 = 0-100 %.UINT16× 0.2398081535%Read
HR11doc 0x000Bdutcyc2 - PWM duty battery 2UINT16× 0.2398081535%Read
HR12doc 0x000Cvmaxb1 - max battery 1 voltageSince last min/max clear.UINT16× 0.0005555556VRead
HR13doc 0x000Dvminb1 - min battery 1 voltageUINT16× 0.0005555556VRead
HR14doc 0x000Evmaxb2 - max battery 2 voltageUINT16× 0.0005555556VRead
HR15doc 0x000Fvminb2 - min battery 2 voltageUINT16× 0.0005555556VRead
HR16doc 0x0010iamax - max solar currentUINT16× 0.0014858841ARead
HR27doc 0x001Btcompcoef - temperature compensation in useUINT16× 0.0005555556VRead
HR28doc 0x001Cpriority - battery 1 charge priorityShare of charge current to battery 1 (0-417 = 0-100 %).UINT16× 0.2398081535%Read
HR29doc 0x001Dvabs1 - absorption voltage battery 1UINT16× 0.0005555556VRead
HR30doc 0x001Eveql1 - equalize voltage battery 1UINT16× 0.0005555556VRead
HR31doc 0x001Fvfloat1 - float voltage battery 1UINT16× 0.0005555556VRead
HR32doc 0x0020vclamp1 - max regulation voltage battery 1UINT16× 0.0005555556VRead
HR33doc 0x0021tfloat1 - float timer battery 1UINT16minRead
HR34doc 0x0022teq1 - equalize timer battery 1UINT16minRead
HR35doc 0x0023vabs2 - absorption voltage battery 2UINT16× 0.0005555556VRead
HR36doc 0x0024veql2 - equalize voltage battery 2UINT16× 0.0005555556VRead
HR37doc 0x0025vfloat2 - float voltage battery 2UINT16× 0.0005555556VRead
HR38doc 0x0026vclamp2 - max regulation voltage battery 2UINT16× 0.0005555556VRead
HR39doc 0x0027tfloat2 - float timer battery 2UINT16minRead
HR40doc 0x0028teq2 - equalize timer battery 2UINT16minRead
HR262doc 0x0106dc1 - duty cycle battery 1Pre-scaled percent.UINT16%Read
HR263doc 0x0107dc2 - duty cycle battery 2UINT16%Read
HR264doc 0x0108state - controller stateUINT16Read1 = NORMAL; 3 = NIGHT; 4 = FAULT
HR265doc 0x0109faults - fault bitfieldBITMAP16Readbit 0 = Reverse polarity solar; bit 1 = Reverse polarity battery 1; bit 2 = Reverse polarity battery 2; bit 3 = Damaged local temperature sensor; bit 4 = Damaged or removed RTS; bit 5 = Over-current; bit 6 = High temperature disconnect; bit 7 = High voltage disconnect
HR266doc 0x010Aflags - controller flagsBITMAP16Readbit 3 = Regulation; bit 4 = Valid RTS; bit 5 = Alternating; bit 6 = On/off regulation; bit 7 = Started
HR267doc 0x010BDIP switch positionsBITMAP16Readbit 0 = DIP 1; bit 1 = DIP 2; bit 2 = DIP 3; bit 3 = DIP 4; bit 4 = DIP 5
HR269doc 0x010Db1_state - battery 1 charge stateUINT16Read0 = NORMAL; 1 = EQUALIZE; 2 = FLOAT
HR270doc 0x010Eb2_state - battery 2 charge stateUINT16Read0 = NORMAL; 1 = EQUALIZE; 2 = FLOAT
HR271doc 0x010Fb1_detect - battery 1 detectedUINT16Read0 = Disconnected; 1 = Connected
HR272doc 0x0110b2_detect - battery 2 detectedUINT16Read0 = Disconnected; 1 = Connected
HR57346doc 0xE002priority_off - battery 1 priority, DIP 3 offEEPROM custom setting (0-417).UINT16× 0.2398081535%Read/write
HR57347doc 0xE003priority_on - battery 1 priority, DIP 3 onUINT16× 0.2398081535%Read/write
HR57348doc 0xE004tcompcoef - temperature compensation (EEPROM)Per 12 V battery per °C; typical 0.030.UINT16× 0.0005555556VRead/write
HR57350doc 0xE006Battery 1 (DIP 1 off) absorption voltageUINT16× 0.0005555556VRead/write
HR57351doc 0xE007Battery 1 (DIP 1 off) equalize voltage0 disables equalize.UINT16× 0.0005555556VRead/write
HR57352doc 0xE008Battery 1 (DIP 1 off) float voltageUINT16× 0.0005555556VRead/write
HR57362doc 0xE012Battery 2 (DIP 2 off) absorption voltageUINT16× 0.0005555556VRead/write
HR57363doc 0xE013Battery 2 (DIP 2 off) equalize voltageUINT16× 0.0005555556VRead/write
HR57364doc 0xE014Battery 2 (DIP 2 off) float voltageUINT16× 0.0005555556VRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)

What Modbus registers does the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) have?

This map lists 52 registers: 5 coils, 47 holding registers. 14 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The hex PDU address in Morningstar's table is the wire address; the spec says all listed addresses are request-PDU addresses, and its example reads battery 1 voltage at 0x0000 (0x5CD0 = 23760 / 1800 = 13.20 V).

What are the minimum Modbus registers to integrate the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)?

Start with HR 0 vb1 - battery 1 voltage (Battery 1 voltage); HR 1 vb2 - battery 2 voltage (Battery 2 voltage); HR 3 ia1 - charge current battery 1 (Charge current battery 1); HR 4 ia2 - charge current battery 2 (Charge current battery 2); HR 264 state - controller state (Controller state); HR 265 faults - fault bitfield (Fault bitfield).

How do I enable Modbus control of the Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)?

The meter port auto-detects Meterbus or Modbus; connect the MSC adapter and poll. Coil 0x00F1 switches the port back to Meterbus for a remote meter.

Where is the official Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus) Modbus documentation?