- SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)
Battery inverter (off-grid sine wave) · Modbus register map
Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) Modbus register map
Updated 17 November 2026
The SureSine-300 is a Morningstar sine-wave inverter (115 V and 220 V versions). Through its RJ-11 meter port and Morningstar's MSC adapter it speaks Modbus RTU: battery voltage, heatsink temperature, fault/alarm bits, load state and nominal output settings in RAM, a remote-off and reset register, and EEPROM custom disconnect/reconnect voltages.
This page lists 24 Modbus registers for the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) — 12 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Morningstar’s own free documentation (linked below) and checked against it.
- Manufacturer
- Morningstar
- Model
- SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)
- Equipment type
- Battery inverter (off-grid sine wave)
- Registers
- 24 (12 writable)
- Transport
- Modbus RTU
- Default unit ID
- 1
- Default serial
- 9600 baud, 8N2
- Documented addressing
- hexadecimal, 0-based
- Also known as
- SureSine, SureSine-300
- Source document
- SureSine-300 Modbus Specification · V03 · rev. 2008-10-29
Integration notes: Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)
Via the MSC adapter at 9600 8N2, ID 1, read 0x0000-0x000E: battery voltage (x 16.92/65536), heatsink temperature, faults, alarms and load state. Write a non-zero value to 0x000F to switch the AC output off remotely.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| HR 4 | Vb - battery voltage, filtered | UINT16 | Battery voltage | Read |
| HR 11 | Load state | UINT16 | Load state | Read |
| HR 7 | Fault bitfield | BITMAP16 | Faults | Read |
| HR 8 | Alarm bitfield | BITMAP16 | Alarms | Read |
| HR 6 | Ths - heatsink temperature | INT16 | Heatsink temperature | Read |
| HR 15 | m_disconnect - remote off | UINT16 | Remote AC off | Read/write |
Enable Modbus control & writes
No enable step; connect a Morningstar MSC MeterBus-to-RS-232 adapter to the meter port.
Byte order & addressing
- The disconnect state (load state 5) is only entered through the meter or the m_disconnect register.
- Output voltage and frequency registers show the nominal setting, not live measurements.
Network setup
- Serial: 9600 baud, 8 data bits, no parity, 2 stop bits, no flow control.
Watch out for
- Reset the inverter after EEPROM writes to clear the settings-edit fault.
Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| HR | 0doc 0x0000 | adc_vb - battery voltage, unfiltered | DC input voltage. | UINT16 | × 0.0002581787 | V | Read | ||
| HR | 4doc 0x0004 | Vb - battery voltage, filtered | DC input voltage with slow filter. | UINT16 | × 0.0002581787 | V | Read | ||
| HR | 6doc 0x0006 | Ths - heatsink temperature | -128 to +127. | INT16 | °C | Read | |||
| HR | 7doc 0x0007 | Fault bitfield | A fault stops the inverter. | BITMAP16 | Read | bit 0 = Reset; bit 1 = Over-current; bit 3 = Software; bit 4 = HVD; bit 5 = Hot (heatsink over 95 °C); bit 6 = DIP switch; bit 7 = Settings edit | |||
| HR | 8doc 0x0008 | Alarm bitfield | Alarms do not stop the inverter. | BITMAP16 | Read | bit 0 = Heatsink sensor open; bit 1 = Heatsink sensor shorted; bit 3 = Heatsink hot (above 80 °C) | |||
| HR | 10doc 0x000A | DIP switch settings | BITMAP16 | Read | bit 0 = DIP 1 on; bit 1 = DIP 2 on; bit 2 = DIP 3 on; bit 3 = DIP 4 on | ||||
| HR | 11doc 0x000B | Load state | UINT16 | Read | 0 = Start-up; 1 = Load on; 2 = LVD warning; 3 = LVD; 4 = Fault; 5 = Load disconnected (by meter/Modbus); 6 = Load off; 8 = Standby | ||||
| HR | 12doc 0x000C | Modulation index | 0xFF = 100 %. | UINT16 | × 0.390625 | % | Read | ||
| HR | 13doc 0x000D | Output voltage setting | Nominal rating, not a measurement. | UINT16 | V | Read | |||
| HR | 14doc 0x000E | Output frequency setting | Nominal rating, not a measurement. | UINT16 | Hz | Read | |||
| HR | 15doc 0x000F | m_disconnect - remote off | Non-zero turns the AC output off; write 0 to resume. | UINT16 | Read/write | ||||
| HR | 16doc 0x0010 | modbus_reset - software reset | Non-zero resets the inverter; returns to 0. | UINT16 | Write | ||||
| HR | 57344doc 0xE000 | EVb_min - minimum battery voltage | Since last reset. | UINT16 | × 0.0002581787 | V | Read | ||
| HR | 57345doc 0xE001 | EVb_max - maximum battery voltage | UINT16 | × 0.0002581787 | V | Read | |||
| HR | 57346doc 0xE002 | Emodbus_id - Modbus ID | 1-247, factory 1. | UINT16 | Read/write | ||||
| HR | 57347doc 0xE003 | Emeter_id - MeterBus ID | 1-15, factory 1. | UINT16 | Read/write | ||||
| HR | 57348doc 0xE004 | Ev_lvd2 - custom low voltage disconnect | 0 disables. | UINT16 | × 0.0002581787 | V | Read/write | ||
| HR | 57349doc 0xE005 | Ev_lvr2 - custom low voltage reconnect | UINT16 | × 0.0002581787 | V | Read/write | |||
| HR | 57350doc 0xE006 | Ev_hvd2 - custom high voltage disconnect | UINT16 | × 0.0002581787 | V | Read/write | |||
| HR | 57351doc 0xE007 | Ev_hvr2 - custom high voltage reconnect | UINT16 | × 0.0002581787 | V | Read/write | |||
| HR | 57352doc 0xE008 | Et_lvd_warn2 - LVD warning timer | UINT16 | × 0.1 | s | Read/write | |||
| HR | 57353doc 0xE009 | Ev_lvdwarn_beep2 - LVD beeper limit | UINT16 | × 0.0002581787 | V | Read/write | |||
| HR | 57354doc 0xE00A | Ev_lvrwarn_beep2 - LVD beeper reset limit | UINT16 | × 0.0002581787 | V | Read/write | |||
| HR | 57355doc 0xE00B | Ev_startlvd2 - start-up LVD setting | UINT16 | × 0.0002581787 | V | Read/write |
Notes on this map
- Voltage scaling is n x 16.92 x 2^-16 (V03 corrected this from 2^-15), converted to the multiplier 16.92/65536.
- Left out: AC output current 0x0001/0x0005, because its scale depends on the version (full scale 6.4 A on 220 V units, 17 A on 115/127 V units: n x 6.4 or 17 x 2^-15). Also the raw thermistor and remote-on voltages (no scaling given), the hourmeter 0xE040 and serial number 0xE044-0xE047 (size and word order not stated).
- The parameters page still says 'TriStar' (copied text); the defaults it gives (9600 8N2, ID 1) are for the SureSine.
- The definitions section repeats several addresses (e.g. hertz and volts both 0x000D, EEPROM entries shifted by one, with LVD warning timer 2 described as a voltage); the register tables are followed here.
- Any EEPROM write sets an 'EEPROM changed' fault until the inverter is reset; writes are not verified. FC 0x03/0x04 read, FC 0x06 writes.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)
What Modbus registers does the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) have?
This map lists 24 registers: 24 holding registers. 12 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The spec says all listed addresses are request-PDU addresses, so the hex value in the PDU column goes on the wire unchanged (logical address = PDU + 1).
What are the minimum Modbus registers to integrate the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)?
Start with HR 4 Vb - battery voltage, filtered (Battery voltage); HR 11 Load state (Load state); HR 7 Fault bitfield (Faults); HR 8 Alarm bitfield (Alarms); HR 6 Ths - heatsink temperature (Heatsink temperature); HR 15 m_disconnect - remote off (Remote AC off).
How do I enable Modbus control of the Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus)?
No enable step; connect a Morningstar MSC MeterBus-to-RS-232 adapter to the meter port.
Where is the official Morningstar SureSine-300 off-grid sine-wave inverter (Modbus RTU via MeterBus) Modbus documentation?
The source is SureSine-300 Modbus Specification (V03), revision 2008-10-29, published free by Morningstar at https://www.morningstarcorp.com/wp-content/uploads/technical-doc-suresine-modbus-specification-en.pdf.
More Morningstar Modbus register maps
- Solar charge controller (PWM, dual battery)
Morningstar SunSaver Duo dual-battery PWM charge controller (Modbus RTU via MeterBus)
Morningstar SunSaver Duo through the MSC MeterBus-to-RS-232 adapter; Modbus specification V04 (19 March 2019). 16-bit registers only.
Also known as: SunSaver Duo, SSDuo - Solar charge controller (MPPT, battery charger)
Morningstar SunSaver MPPT solar charge controller (Modbus RTU via MeterBus)
Morningstar SunSaver MPPT through the MSC MeterBus-to-RS-232 adapter; Modbus specification v11.
Also known as: SunSaver MPPT, SS-MPPT - Solar charge controller (PWM charge / load / diversion)
Morningstar TriStar TS-45 / TS-60 PWM charge, load and diversion controller (Modbus RTU)
Morningstar TriStar TS-45 and TS-60 (non-MPPT) on the RS-232 port; Modbus specification V07 (31 Jan 2020).
Also known as: TS-45, TS-60, TriStar, TriStar PWM
Other solar & battery inverters register maps
- Solar inverter
SolarEdge SolarEdge inverters (SunSpec logging)
SolarEdge single-, split- and three-phase inverters with SunSpec enabled (SolarEdge Go/SetApp units, or LCD units on firmware 3.xxxx+); meter 1 at the non-Synergy default base.
Also known as: SE5000, Synergy, SolarEdge SunSpec - Battery inverter (GX gateway for inverter/chargers, batteries and solar chargers)
Victron Energy GX device Modbus-TCP (Cerbo GX, Venus GX, Color Control GX)
Victron GX devices running Venus OS with the Modbus-TCP service enabled; register list version 3.81 (document Rev 54). Core system, VE.Bus inverter/charger, battery, solar charger and ESS registers only.
Also known as: Cerbo GX, Cerbo-S GX, Venus GX, Color Control GX, CCGX, Ekrano GX, Octo GX, MultiPlus-II GX, EasySolar-II GX, Venus OS, dbus-modbustcp - Battery charger (industrial float charger, UPS-type DC system)
HindlePower ATevo battery charger (Modbus communications adapter)
HindlePower ATevo battery chargers with the serial or Ethernet communications adapter set to Modbus, per the ATevo Communications online manual version 1.3.
Also known as: ATevo, ATevo Communications - Sensor (battery monitor for Studer systems)
Studer Innotec BSP battery status processor (via Xcom-485i)
Studer BSP-500 and BSP-1200 battery status processors read through an Xcom-485i Modbus RTU gateway, system release R706.
Also known as: BSP-500, BSP-1200, BSP500, BSP1200, Xcom-485i - Solar inverter
Fronius Primo GEN24 / Symo GEN24 (Plus) SunSpec int+SF
Fronius Primo/Symo GEN24 (Plus) rest-of-world variants with a battery configured, SunSpec Model Type int+SF; without a battery the MPPT model has 2 inputs and model 124 is absent.
Also known as: Primo GEN24 Plus, Symo GEN24 Plus, Primo GEN24, Symo GEN24, Symo GEN24 10.0 Plus, Primo GEN24 6.0 Plus - Solar inverter gateway (smart dongle)
Huawei SDongleA smart dongle (Modbus TCP)
Huawei SDongleA WLAN/WLAN-FE/4G dongles with firmware V100R001C00SPC100 or later, per MODBUS Interface Definitions issue 05.
Also known as: SDongleA-01, SDongleA-02-CN, SDongleA-03-EU, SDongleA-03-AU, SDongleA-03-KR, SDongleA-03-JP, SDongleA-03-CN
All solar & battery inverters Modbus register maps →
Source: SureSine-300 Modbus Specification · V03 · rev. 2008-10-29. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.