Condair Modbus register maps
Updated 17 November 2026
5 Condair models, 338 registers in all, each re-typed from Condair’s own free documentation and checked against it.
- Air handler humidifier (hybrid / spray)
Condair DL II hybrid humidifier (Integrated Controller, Modbus RTU/TCP)
Condair DL with the Integrated Controller, per addendum 2603326-G.
Also known as: Condair DL, Condair DL II, DL - Air handler humidifier (evaporative)
Condair ME II evaporative humidifier / cooler (Integrated Controller, Modbus RTU/TCP)
Condair ME with the Integrated Controller, per addendum 2603326-G.
Also known as: Condair ME, Condair ME II, ME - Pump (reverse osmosis water treatment unit)
Condair RO-E reverse osmosis water treatment (Integrated Controller, Modbus RTU/TCP)
Condair RO-E / RO-E+ with the Integrated Controller, per addendum 2603326-G.
Also known as: Condair RO-E, RO-E+, Condair RO-E+ - Air handler humidifier (resistive steam)
Condair RS II resistive steam humidifier (Integrated Controller, Modbus RTU/TCP)
Condair RS with the Integrated Controller (cylinders A and B), per addendum 2603326-G.
Also known as: Condair RS, Condair RS II, RS - Air handler humidifier (high-pressure room system)
Condair Vita high-pressure humidification system (Integrated Controller, Modbus RTU/TCP)
Condair Vita system with the Integrated Controller, per addendum 2603326-G.
Also known as: Condair Vita, Vita System Master
Condair: default communication settings
Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).
| Model | Transport | Unit ID | Serial | Word order | Documented addressing | Registers |
|---|---|---|---|---|---|---|
| DL II hybrid humidifier (Integrated Controller, Modbus RTU/TCP) | RTU/TCP | 10 | 19200 baud, 8E1 | ABCD | Modicon | 40 |
| ME II evaporative humidifier / cooler (Integrated Controller, Modbus RTU/TCP) | RTU/TCP | 10 | 19200 baud, 8E1 | ABCD | Modicon | 60 |
| RO-E reverse osmosis water treatment (Integrated Controller, Modbus RTU/TCP) | RTU/TCP | 10 | 19200 baud, 8E1 | ABCD | Modicon | 20 |
| RS II resistive steam humidifier (Integrated Controller, Modbus RTU/TCP) | RTU/TCP | 10 | 19200 baud, 8E1 | ABCD | Modicon | 59 |
| Vita high-pressure humidification system (Integrated Controller, Modbus RTU/TCP) | RTU/TCP | 10 | 19200 baud, 8E1 | ABCD | Modicon | 159 |