Manufacturer
SATEC Modbus register maps
Updated 17 November 2026
7 SATEC models, 722 registers in all, each re-typed from SATEC’s own free documentation and checked against it.
- Power meter (multi-circuit branch feeder monitor)
SATEC BFM-II branch feeder monitor
SATEC BFM-II multi-circuit meter per Modbus reference guide BG0589 Rev. A12 (May 2024); per-submeter 32-bit measurement registers plus shared setup.
Also known as: BFM II, BFM2, SATEC BFM-II - Power meter (multi-circuit branch feeder monitor)
SATEC BFM136/036 branch feeder monitor
SATEC BFM136 and BFM036 multi-circuit meters per Modbus reference guide BG0395 Rev. A8 (July 2024); per-submeter 32-bit measurement registers plus shared setup.
Also known as: BFM136, BFM036, BFM 136, SATEC BFM136 - Energy meter (multifunction)
SATEC EM133-R residential multifunction meter
SATEC EM133-R (and EM133-XM) multifunction meters, per Modbus reference guide BG0520 Rev. A6 (Oct 2018).
Also known as: EM133, EM133-R, EM133-XM, SATEC EM133 - Power meter (revenue / power quality)
SATEC EM235 / PM335 PRO advanced power meter
SATEC EM235 and PM335 PRO advanced power meters, per Modbus reference guide BG0613 Rev. A8 (Sept 2025).
Also known as: EM235, PM335 PRO, PM335PRO, SATEC EM235, SATEC PM335 - Power meter (power quality analyzer)
SATEC PM174 powermeter and power quality analyzer
SATEC PM174 from firmware 24.3.1, per Modbus reference guide BG0414 Rev. A7 (April 2013).
Also known as: PM174, SATEC PM174, PM 174 - Power meter (power quality analyzer)
SATEC PM175 powermeter and power quality analyzer
SATEC PM175 from firmware 25.2.6, per Modbus reference guide BG0416 Rev. A7 (Nov 2009).
Also known as: PM175, SATEC PM175, PM 175 - Power meter (power quality analyzer)
SATEC PM180 expertmeter high performance analyzer
SATEC PM180 expertmeter, per Modbus reference guide BG0527 Rev. A11 (Sep 2024).
Also known as: PM180, expertmeter PM180, SATEC PM180
SATEC: default communication settings
Factory defaults as the manufacturer documents them. Change one setting at a time on site and write down what you changed. Word order applies to 32-bit values; the addressing column says how the manufacturer prints register numbers (every map on this site also gives the 0-based wire address).
| Model | Transport | Unit ID | Serial | Word order | Documented addressing | Registers |
|---|---|---|---|---|---|---|
| BFM-II branch feeder monitor | RTU/ASCII/TCP | 1 | - | CDAB | 0-based | 83 |
| BFM136/036 branch feeder monitor | RTU/ASCII/TCP | 1 | - | CDAB | 0-based | 72 |
| EM133-R residential multifunction meter | RTU/TCP | Not stated | - | CDAB | 0-based | 104 |
| EM235 / PM335 PRO advanced power meter | RTU/ASCII/TCP | Not stated | - | CDAB | 0-based | 122 |
| PM174 powermeter and power quality analyzer | RTU/ASCII/TCP | Not stated | - | CDAB | 0-based | 103 |
| PM175 powermeter and power quality analyzer | RTU/ASCII/TCP | Not stated | - | CDAB | 0-based | 109 |
| PM180 expertmeter high performance analyzer | RTU/ASCII/TCP | Not stated | - | CDAB | 0-based | 129 |