- Home
- Modbus register maps
- SISGEO
- SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
Sensor (geotechnical: inclinometer, tiltmeter, piezometer, extensometer) · Modbus register map
SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus register map
Updated 17 November 2026
Common Modbus RTU register set of SISGEO's digital geotechnical instruments (in-place inclinometers, tiltmeters, piezometers, extensometers). Input registers give update counters, physical readings as IEEE-754 floats and fixed-point integers, electrical readings, supply voltage and internal temperature/humidity; holding registers hold version, address, baud rate, timed-mode options and power-down.
This page lists 52 Modbus registers for the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) — 4 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from SISGEO’s own free documentation (linked below) and checked against it.
- Manufacturer
- SISGEO
- Model
- SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
- Registers
- 52 (4 writable)
- Transport
- Modbus RTU
- Default unit ID
- Not stated
- Default serial
- 9600 baud, 8N1
- Documented addressing
- hexadecimal, 0-based
- 32-bit word order
- ABCD high word first (big-endian)
- Firmware
- >= 0x0300 (normal mode)
- Also known as
- SISGEO digital in-place inclinometer, SISGEO digital tiltmeter, SISGEO digital piezometer, SISGEO DEX, SISGEO digital extensometer
- Source document
- SISGEO MODBUS protocol manual · EN 05/20 · rev. 2020-05
Integration notes: SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
Read IR_PHYSICAL_COUNT plus the physical float channels in one FC04 request from 0x0200, decode the floats high word first, and use the count to detect new readings.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| IR 512 | IR_PHYSICAL_COUNT | UINT16 | New-reading counter | Read |
| IR 514 | IR_PHYSICAL_CHANNEL_0 | FLOAT32 ABCD | Physical channel 0 | Read |
| IR 516 | IR_PHYSICAL_CHANNEL_1 | FLOAT32 ABCD | Physical channel 1 | Read |
| IR 518 | IR_PHYSICAL_CHANNEL_2 | FLOAT32 ABCD | Physical channel 2 | Read |
| IR 1025 | IR_SUPPLY | UINT16 | Supply voltage | Read |
| IR 1032 | IR_TEMPERATURE | INT16 | Board temperature | Read |
Enable Modbus control & writes
Instruments ship in always-on mode (except DEX/DEX-S) at address and baud set in the user configuration; no enable step.
Byte order & addressing
- Input and holding registers share address numbers but are different data; use FC04 for readings and FC03 for configuration.
- Floats and 32-bit integers are high word first; the configuration Scale pair is low word first.
Network setup
- 9600 baud, 8N1 by default; baud stored in 0x0142 as baud/100.
- Address 1..247 in 0x0103.
- In timed mode units come online after initial + address x incremental delay seconds.
Watch out for
- Writing 0xFF to HR_RESET switches the unit off until power is cycled.
- The moving average needs about two IR_PHYSICAL_CHANGE increments to settle after the input changes.
SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| IR | 512doc 0x200 | IR_PHYSICAL_COUNT | Increments each time all physical channels are updated. | UINT16 | Read | ||||
| IR | 513doc 0x201 | IR_PHYSICAL_CHANGE | Increments when all moving averages have fully refreshed. | UINT16 | Read | ||||
| IR | 514doc 0x202 | IR_PHYSICAL_CHANNEL_0 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 516doc 0x204 | IR_PHYSICAL_CHANNEL_1 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 518doc 0x206 | IR_PHYSICAL_CHANNEL_2 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 520doc 0x208 | IR_PHYSICAL_CHANNEL_3 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 522doc 0x20A | IR_PHYSICAL_CHANNEL_4 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 524doc 0x20C | IR_PHYSICAL_CHANNEL_5 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 526doc 0x20E | IR_PHYSICAL_CHANNEL_6 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 528doc 0x210 | IR_PHYSICAL_CHANNEL_7 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 530doc 0x212 | IR_PHYSICAL_CHANNEL_8 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 532doc 0x214 | IR_PHYSICAL_CHANNEL_9 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 534doc 0x216 | IR_PHYSICAL_CHANNEL_10 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 536doc 0x218 | IR_PHYSICAL_CHANNEL_11 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 538doc 0x21A | IR_PHYSICAL_CHANNEL_12 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 540doc 0x21C | IR_PHYSICAL_CHANNEL_13 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 542doc 0x21E | IR_PHYSICAL_CHANNEL_14 | Physical reading; meaning and unit depend on the instrument and channel. | FLOAT32 | ABCD | Read | |||
| IR | 544doc 0x220 | IR_PHYSICAL_INT_COUNT | Same counter as IR_PHYSICAL_COUNT. | UINT16 | Read | ||||
| IR | 546doc 0x222 | IR_PHYSICAL_INT_CHANNEL_0 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 548doc 0x224 | IR_PHYSICAL_INT_CHANNEL_1 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 550doc 0x226 | IR_PHYSICAL_INT_CHANNEL_2 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 552doc 0x228 | IR_PHYSICAL_INT_CHANNEL_3 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 554doc 0x22A | IR_PHYSICAL_INT_CHANNEL_4 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 556doc 0x22C | IR_PHYSICAL_INT_CHANNEL_5 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 558doc 0x22E | IR_PHYSICAL_INT_CHANNEL_6 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 560doc 0x230 | IR_PHYSICAL_INT_CHANNEL_7 | Physical reading x the channel's configured multiplier (default 1), rounded. | INT32 | ABCD | Read | |||
| IR | 578doc 0x242 | IR_ELECTRICAL_CHANNEL_0 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 580doc 0x244 | IR_ELECTRICAL_CHANNEL_1 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 582doc 0x246 | IR_ELECTRICAL_CHANNEL_2 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 584doc 0x248 | IR_ELECTRICAL_CHANNEL_3 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 586doc 0x24A | IR_ELECTRICAL_CHANNEL_4 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 588doc 0x24C | IR_ELECTRICAL_CHANNEL_5 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 590doc 0x24E | IR_ELECTRICAL_CHANNEL_6 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 592doc 0x250 | IR_ELECTRICAL_CHANNEL_7 | Electrical value of the channel (e.g. mV). | FLOAT32 | ABCD | Read | |||
| IR | 1025doc 0x0401 | IR_SUPPLY | Supply voltage. | UINT16 | × 0.1 | V | Read | ||
| IR | 1026doc 0x0402 | IR_UID_0 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1027doc 0x0403 | IR_UID_1 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1028doc 0x0404 | IR_UID_2 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1029doc 0x0405 | IR_UID_3 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1030doc 0x0406 | IR_UID_4 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1031doc 0x0407 | IR_UID_5 | Factory-set unique ID word. | UINT16 | Read | ||||
| IR | 1032doc 0x0408 | IR_TEMPERATURE | Electronics board temperature. | INT16 | × 0.1 | °C | Read | ||
| IR | 1033doc 0x0409 | IR_HUMIDITY | Humidity inside the instrument (leak detection). | UINT16 | × 0.1 | %RH | Read | ||
| HR | 0doc 0x0000 | HR_VERSION_FW | Firmware version, MSB major / LSB minor in hex (e.g. 0x0311). | UINT16 | Read | ||||
| HR | 1doc 0x0001 | HR_VERSION_HW | Hardware version of the electronics board. | UINT16 | Read | ||||
| HR | 2doc 0x0002 | HR_VERSION_BIOS | Bootloader (BIOS) version. | UINT16 | Read | ||||
| HR | 16doc 0x0010 | HR_RESET | Write 0xFF to power the unit down until the next power cycle. | UINT16 | Write | 255 = Power the unit down | |||
| HR | 258doc 0x0102 | HR_USR_OPTIONS (Timed) | 0 = always on; else MSB incremental delay, LSB initial delay (s). | UINT16 | Read/write | 0 = Always on (timed mode off) | |||
| HR | 259doc 0x0103 | HR_USR_CFG_ADDRESS | Modbus slave address, 1..247. | UINT16 | Read/write | ||||
| HR | 260doc 0x0104 | HR_USR_CFG_SERIAL_1 | Serial number part 1 (writes have no effect). | UINT16 | Read | ||||
| HR | 261doc 0x0105 | HR_USR_CFG_SERIAL_2 | Serial number part 2. | UINT16 | Read | ||||
| HR | 322doc 0x0142 | HR_USR_CFG_BAUD | Baud rate / 100 (96 = 9600). | UINT16 | Read/write |
Notes on this map
- Word order: the manual shows the float's sign/exponent bits in the first register (e.g. 0x202) and the rest in the second, and states for integer and fixed-point pairs that the most significant word comes first. All listed 32-bit values are ABCD.
- The channel-configuration 'Scale' pair is the exception: the manual says it is stored least significant word first. Those configuration registers (0x0148 onward) are not listed.
- What each physical channel holds (tilt, pressure, temperature, etc.) depends on the instrument; see its own datasheet and user manual.
- Only physical channels 0-14 (float), fixed-point channels 0-7 and electrical channels 0-7 are listed; fixed-point and electrical blocks run to channel 14 at the same 2-register spacing.
- Raw ADC registers (0x260+) are left out: the manual's table repeats addresses 0x260-0x26E for channels 7-14, so the layout cannot be trusted. Legacy-mode registers (0x0100-0x012B input) are also left out.
- IR_PHYSICAL_COUNT changes when a new averaged reading is ready; the manual advises waiting for two increments of IR_PHYSICAL_CHANGE after an input change before trusting the value.
- IR_TEMPERATURE is listed as signed (INT16); the manual gives it in tenths of a degree Celsius but does not state the sign convention.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
What Modbus registers does the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) have?
This map lists 52 registers: 43 input registers, 9 holding registers. 4 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Registers are printed as hexadecimal addresses. The manual lists a holding register at 0x0000 (HR_VERSION_FW, 'read Holding Register 0x0000'), which only exists in 0-based protocol addressing, so the printed hex values are the wire addresses. The input-register tables print short forms such as 0x202; 'documented' keeps the form used in each table.
What byte order does the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) use for 32-bit values?
Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.
What are the minimum Modbus registers to integrate the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)?
Start with IR 512 IR_PHYSICAL_COUNT (New-reading counter); IR 514 IR_PHYSICAL_CHANNEL_0 (Physical channel 0); IR 516 IR_PHYSICAL_CHANNEL_1 (Physical channel 1); IR 518 IR_PHYSICAL_CHANNEL_2 (Physical channel 2); IR 1025 IR_SUPPLY (Supply voltage); IR 1032 IR_TEMPERATURE (Board temperature).
How do I enable Modbus control of the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)?
Instruments ship in always-on mode (except DEX/DEX-S) at address and baud set in the user configuration; no enable step.
Where is the official SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus documentation?
The source is SISGEO MODBUS protocol manual (EN 05/20), revision 2020-05, published free by SISGEO at https://sisgeo.com/wp-content/uploads/2023/07/SISGEO_MODBUS_protocol_manual_-_EN_05_20.pdf.
Other power & energy meters register maps
- Energy meter
ABB EQ meter A41 / A42 (Modbus RTU)
ABB EQ A41 (direct connected) and A42 (transformer connected) DIN meters whose RS-485 port is set to Modbus.
Also known as: A41, A42, EQ A41, EQ A42 - Power meter (circuit breaker trip unit)
ABB SACE Tmax PR223DS trip unit (Modbus RTU)
ABB SACE PR223DS electronic trip unit (Tmax moulded-case breakers), software version 02.02, per 1SDH000658R0001.
Also known as: PR223DS, Tmax PR223DS, SACE PR223DS - Power meter
BTicino PM multifunction meter F3N200 (Modbus RTU)
BTicino PM multifunction meter catalogue number F3N200 with RS-485, per Modbus table IDP000024 v1.01.
Also known as: F3N200, BTicino PM F3N200 - Energy meter (energy analyzer)
Carlo Gavazzi EM24-DIN Ethernet (E1)
EM24-DIN energy analyzers with the E1 Ethernet (RJ45) Modbus TCP port, AV2 and AV5 inputs, X/PFA/PFB, protocol version 0 revision 1.3 (FW 1.0).
Also known as: EM24 E1, EM24_E1, EM24DINAV23XE1X, EM24DINAV23XE1PFA, EM24DINAV23XE1PFB, EM24DINAV53XE1X, EM24DINAV53XE1PFA, EM24DINAV53XE1PFB - Energy meter
Carlo Gavazzi EM580 three-phase AC energy meter for EV chargers (Modbus RTU)
EM580-IS MID/Eichrecht AC meters (DEB, DET, DEA variants, 256/384-bit signatures), protocol version 1.11.
Also known as: EM580-IS, EM580DINAV23XS2DEB, EM580DINAV23XS3DEB, EM580DINAV23XS2DET, EM580DINAV23XS3DET, EM580DINAV23XS2DEA, EM580DINAV23XS3DEA - Power meter
Circutor CVM-C10
Circutor CVM-C10 panel power analyzer, RS-485 versions (ITF, MC, mV, ITF-IN), manual M001B01-03-23A.
Also known as: CVM-C10-ITF-485, CVM-C10-MC-485, CVM-C10-mV-485, CVM-C10-ITF-IN-485
All power & energy meters Modbus register maps →
Source: SISGEO MODBUS protocol manual · EN 05/20 · rev. 2020-05. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.