  4. SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)

Sensor (geotechnical: inclinometer, tiltmeter, piezometer, extensometer) · Modbus register map

SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus register map

Updated 17 November 2026

Short answer

Common Modbus RTU register set of SISGEO's digital geotechnical instruments (in-place inclinometers, tiltmeters, piezometers, extensometers). Input registers give update counters, physical readings as IEEE-754 floats and fixed-point integers, electrical readings, supply voltage and internal temperature/humidity; holding registers hold version, address, baud rate, timed-mode options and power-down.

This page lists 52 Modbus registers for the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) — 4 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from SISGEO’s own free documentation (linked below) and checked against it.

Manufacturer
SISGEO
Model
SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
Equipment type
Sensor (geotechnical: inclinometer, tiltmeter, piezometer, extensometer)
Registers
52 (4 writable)
Transport
Modbus RTU
Default unit ID
Not stated
Default serial
9600 baud, 8N1
Documented addressing
hexadecimal, 0-based
32-bit word order
ABCD high word first (big-endian)
Firmware
>= 0x0300 (normal mode)
Also known as
SISGEO digital in-place inclinometer, SISGEO digital tiltmeter, SISGEO digital piezometer, SISGEO DEX, SISGEO digital extensometer
Source document
SISGEO MODBUS protocol manual · EN 05/20 · rev. 2020-05
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)

Integration in brief

Read IR_PHYSICAL_COUNT plus the physical float channels in one FC04 request from 0x0200, decode the floats high word first, and use the count to detect new readings.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 512IR_PHYSICAL_COUNTUINT16New-reading counterRead
IR 514IR_PHYSICAL_CHANNEL_0FLOAT32 ABCDPhysical channel 0Read
IR 516IR_PHYSICAL_CHANNEL_1FLOAT32 ABCDPhysical channel 1Read
IR 518IR_PHYSICAL_CHANNEL_2FLOAT32 ABCDPhysical channel 2Read
IR 1025IR_SUPPLYUINT16Supply voltageRead
IR 1032IR_TEMPERATUREINT16Board temperatureRead

Enable Modbus control & writes

Instruments ship in always-on mode (except DEX/DEX-S) at address and baud set in the user configuration; no enable step.

Byte order & addressing

Network setup

Watch out for

SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

52 of 52 shown
SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR512doc 0x200IR_PHYSICAL_COUNTIncrements each time all physical channels are updated.UINT16Read
IR513doc 0x201IR_PHYSICAL_CHANGEIncrements when all moving averages have fully refreshed.UINT16Read
IR514doc 0x202IR_PHYSICAL_CHANNEL_0Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR516doc 0x204IR_PHYSICAL_CHANNEL_1Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR518doc 0x206IR_PHYSICAL_CHANNEL_2Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR520doc 0x208IR_PHYSICAL_CHANNEL_3Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR522doc 0x20AIR_PHYSICAL_CHANNEL_4Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR524doc 0x20CIR_PHYSICAL_CHANNEL_5Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR526doc 0x20EIR_PHYSICAL_CHANNEL_6Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR528doc 0x210IR_PHYSICAL_CHANNEL_7Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR530doc 0x212IR_PHYSICAL_CHANNEL_8Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR532doc 0x214IR_PHYSICAL_CHANNEL_9Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR534doc 0x216IR_PHYSICAL_CHANNEL_10Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR536doc 0x218IR_PHYSICAL_CHANNEL_11Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR538doc 0x21AIR_PHYSICAL_CHANNEL_12Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR540doc 0x21CIR_PHYSICAL_CHANNEL_13Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR542doc 0x21EIR_PHYSICAL_CHANNEL_14Physical reading; meaning and unit depend on the instrument and channel.FLOAT32ABCDRead
IR544doc 0x220IR_PHYSICAL_INT_COUNTSame counter as IR_PHYSICAL_COUNT.UINT16Read
IR546doc 0x222IR_PHYSICAL_INT_CHANNEL_0Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR548doc 0x224IR_PHYSICAL_INT_CHANNEL_1Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR550doc 0x226IR_PHYSICAL_INT_CHANNEL_2Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR552doc 0x228IR_PHYSICAL_INT_CHANNEL_3Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR554doc 0x22AIR_PHYSICAL_INT_CHANNEL_4Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR556doc 0x22CIR_PHYSICAL_INT_CHANNEL_5Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR558doc 0x22EIR_PHYSICAL_INT_CHANNEL_6Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR560doc 0x230IR_PHYSICAL_INT_CHANNEL_7Physical reading x the channel's configured multiplier (default 1), rounded.INT32ABCDRead
IR578doc 0x242IR_ELECTRICAL_CHANNEL_0Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR580doc 0x244IR_ELECTRICAL_CHANNEL_1Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR582doc 0x246IR_ELECTRICAL_CHANNEL_2Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR584doc 0x248IR_ELECTRICAL_CHANNEL_3Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR586doc 0x24AIR_ELECTRICAL_CHANNEL_4Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR588doc 0x24CIR_ELECTRICAL_CHANNEL_5Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR590doc 0x24EIR_ELECTRICAL_CHANNEL_6Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR592doc 0x250IR_ELECTRICAL_CHANNEL_7Electrical value of the channel (e.g. mV).FLOAT32ABCDRead
IR1025doc 0x0401IR_SUPPLYSupply voltage.UINT16× 0.1VRead
IR1026doc 0x0402IR_UID_0Factory-set unique ID word.UINT16Read
IR1027doc 0x0403IR_UID_1Factory-set unique ID word.UINT16Read
IR1028doc 0x0404IR_UID_2Factory-set unique ID word.UINT16Read
IR1029doc 0x0405IR_UID_3Factory-set unique ID word.UINT16Read
IR1030doc 0x0406IR_UID_4Factory-set unique ID word.UINT16Read
IR1031doc 0x0407IR_UID_5Factory-set unique ID word.UINT16Read
IR1032doc 0x0408IR_TEMPERATUREElectronics board temperature.INT16× 0.1°CRead
IR1033doc 0x0409IR_HUMIDITYHumidity inside the instrument (leak detection).UINT16× 0.1%RHRead
HR0doc 0x0000HR_VERSION_FWFirmware version, MSB major / LSB minor in hex (e.g. 0x0311).UINT16Read
HR1doc 0x0001HR_VERSION_HWHardware version of the electronics board.UINT16Read
HR2doc 0x0002HR_VERSION_BIOSBootloader (BIOS) version.UINT16Read
HR16doc 0x0010HR_RESETWrite 0xFF to power the unit down until the next power cycle.UINT16Write255 = Power the unit down
HR258doc 0x0102HR_USR_OPTIONS (Timed)0 = always on; else MSB incremental delay, LSB initial delay (s).UINT16Read/write0 = Always on (timed mode off)
HR259doc 0x0103HR_USR_CFG_ADDRESSModbus slave address, 1..247.UINT16Read/write
HR260doc 0x0104HR_USR_CFG_SERIAL_1Serial number part 1 (writes have no effect).UINT16Read
HR261doc 0x0105HR_USR_CFG_SERIAL_2Serial number part 2.UINT16Read
HR322doc 0x0142HR_USR_CFG_BAUDBaud rate / 100 (96 = 9600).UINT16Read/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)

What Modbus registers does the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) have?

This map lists 52 registers: 43 input registers, 9 holding registers. 4 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Registers are printed as hexadecimal addresses. The manual lists a holding register at 0x0000 (HR_VERSION_FW, 'read Holding Register 0x0000'), which only exists in 0-based protocol addressing, so the printed hex values are the wire addresses. The input-register tables print short forms such as 0x202; 'documented' keeps the form used in each table.

What byte order does the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)?

Start with IR 512 IR_PHYSICAL_COUNT (New-reading counter); IR 514 IR_PHYSICAL_CHANNEL_0 (Physical channel 0); IR 516 IR_PHYSICAL_CHANNEL_1 (Physical channel 1); IR 518 IR_PHYSICAL_CHANNEL_2 (Physical channel 2); IR 1025 IR_SUPPLY (Supply voltage); IR 1032 IR_TEMPERATURE (Board temperature).

How do I enable Modbus control of the SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)?

Instruments ship in always-on mode (except DEX/DEX-S) at address and baud set in the user configuration; no enable step.

Where is the official SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode) Modbus documentation?

The source is SISGEO MODBUS protocol manual (EN 05/20), revision 2020-05, published free by SISGEO at https://sisgeo.com/wp-content/uploads/2023/07/SISGEO_MODBUS_protocol_manual_-_EN_05_20.pdf.

Other power & energy meters register maps

All power & energy meters Modbus register maps →

Source: SISGEO MODBUS protocol manual · EN 05/20 · rev. 2020-05. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.