DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) Modbus register map

Updated 17 November 2026

Short answer

The SEN0662 is a maker-grade particulate sensor board built on the Bosch BMV080. With its DIP switch on the UART side it acts as a Modbus RTU slave. Input registers give PM1.0, PM2.5 and PM10 as big-endian floats plus status; holding registers set the address, serial format and measurement mode and start or stop measurement.

This page lists 26 Modbus registers for the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) — 10 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from DFRobot’s own free documentation (linked below) and checked against it.

Manufacturer
DFRobot
Model
SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU)
Equipment type
Sensor (particulate matter)
Registers
26 (10 writable)
Transport
Modbus RTU
Default unit ID
87
Default serial
9600 baud, 8N1
Documented addressing
hexadecimal, 0-based
32-bit word order
ABCD high word first (big-endian)
Firmware
V1.0.0 (0x1000), register map version 0x0004
Also known as
SEN0662, Gravity BMV080, BMV080 PM2.5 sensor, DFRobot BMV080
Source document
Gravity: BMV080 PM2.5 Air Quality Sensor - Modbus Register Definitions (SEN0662 wiki)
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU)

Integration in brief

At 9600 8N1, address 0x57: write 0x0001 to holding register 0x0003 to start measuring, then read six input registers from 0x0006 with function 04 for PM1.0, PM2.5 and PM10 as big-endian floats in ug/m3.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 3Operation CommandUINT16Start measurement commandWrite
IR 6PM1.0FLOAT32 ABCDPM1.0Read
IR 8PM2.5FLOAT32 ABCDPM2.5Read
IR 10PM10FLOAT32 ABCDPM10Read
IR 14Status FlagsBITMAP16Status flagsRead
IR 4Operating StatusUINT16Operating statusRead

Enable Modbus control & writes

Set the module's DIP switch to the UART side; Modbus RTU is then active at the stored address and baud rate.

Byte order & addressing

Network setup

Watch out for

DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

26 of 26 shown
DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR0doc 0x0000Product ID (PIDR)Reads 0x0296 for this module.UINT16Read
IR1doc 0x0001Vendor ID (VIDR)Reads 0x3343 (DFRobot).UINT16Read
IR2doc 0x0002Firmware Version0x1000 = V1.0.0.UINT16Read
IR3doc 0x0003Register Map VersionDefault 0x0004.UINT16Read
IR4doc 0x0004Operating StatusUINT16Read0 = Booting; 1 = Ready, waiting for measurement; 2 = Continuous measurement running; 3 = Duty-cycle measurement running; 4 = Stopped; 5 = Error
IR5doc 0x0005Last Status CodeResult of the last BMV080 SDK call; 0 = success.UINT16Read
IR6doc 0x0006PM1.0Mass concentration, IEEE 754 float, high word first.FLOAT32ABCDµg/m³Read
IR8doc 0x0008PM2.5Mass concentration, IEEE 754 float, high word first.FLOAT32ABCDµg/m³Read
IR10doc 0x000APM10Mass concentration, IEEE 754 float, high word first.FLOAT32ABCDµg/m³Read
IR12doc 0x000COperating DurationFloat, high word first.FLOAT32ABCDsRead
IR14doc 0x000EStatus FlagsStatus bits; bits 10-15 reserved.BITMAP16Readbit 0 = Sensor blockage; bit 1 = PM2.5 out of range; bit 2 = New PM data ready (cleared once data, flags and counter are read); bit 3 = Sensor initialisation complete; bit 4 = Measurement in progress; bit 5 = Parameter change pending; bit 6 = Parameters validated; bit 7 = Parameters being applied; bit 8 = Reserved (always 0 with float map); bit 9 = A float input was NaN/Inf and was written as 0
IR15doc 0x000FSample CounterIncrements per sample; wraps after 65535.UINT16Read
IR16doc 0x0010SDK Major VersionUINT16Read
IR17doc 0x0011SDK Minor VersionUINT16Read
IR18doc 0x0012SDK Patch VersionUINT16Read
IR19doc 0x0013Sensor Unique ID12 ASCII characters across 6 registers, high byte first.STRING[12]Read
HR0doc 0x0000RTU Slave Address1-247, default 0x57; stored in non-volatile memory.UINT16Read/write
HR1doc 0x0001Baud RateStored; applies after reboot.UINT16Read/write1 = 2400; 2 = 4800; 3 = 9600; 4 = 14400; 5 = 19200; 6 = 38400; 7 = 57600; 8 = 115200
HR2doc 0x0002Parity & Stop Bit ConfigurationHigh byte parity: 0 none, 1 even, 2 odd. Low byte stop bits: 1=1, 2=1.5, 3=2.UINT16Read/write
HR3doc 0x0003Operation CommandReads back 0. Not stored.UINT16Write1 = Start measurement; 2 = Stop measurement; 3 = Restore default configuration
HR4doc 0x0004Measurement ModeSend a start command after changing.UINT16Read/write0 = Continuous; 1 = Duty cycle
HR5doc 0x0005Measurement AlgorithmDuty-cycle mode forces Fast Response.UINT16Read/write1 = Fast Response; 2 = Balanced; 3 = High Precision
HR6doc 0x0006Blockage Detection SwitchUINT16Read/write0 = Disabled; 1 = Enabled
HR7doc 0x0007Vibration Filter SwitchUINT16Read/write0 = Disabled; 1 = Enabled
HR8doc 0x0008Integration TimeFloat, high word first; default 10.0.FLOAT32ABCDRead/write
HR10doc 0x000ADuty-Cycle PeriodIntegration time plus sleep time; default 30.UINT16sRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU)

What Modbus registers does the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) have?

This map lists 26 registers: 16 input registers, 10 holding registers. 10 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Registers are listed as hex protocol addresses from 0x0000 and sent unchanged; the wiki's example reads PM1.0 with start address 0x0006 on function 04.

What byte order does the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU)?

Start with HR 3 Operation Command (Start measurement command); IR 6 PM1.0 (PM1.0); IR 8 PM2.5 (PM2.5); IR 10 PM10 (PM10); IR 14 Status Flags (Status flags); IR 4 Operating Status (Operating status).

How do I enable Modbus control of the DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU)?

Set the module's DIP switch to the UART side; Modbus RTU is then active at the stored address and baud rate.

Where is the official DFRobot SEN0662 Gravity BMV080 PM2.5 air quality sensor (UART Modbus RTU) Modbus documentation?

The source is Gravity: BMV080 PM2.5 Air Quality Sensor - Modbus Register Definitions (SEN0662 wiki), published free by DFRobot at https://wiki.dfrobot.com/sen0662/docs/25056.

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: Gravity: BMV080 PM2.5 Air Quality Sensor - Modbus Register Definitions (SEN0662 wiki). Register numbers, types, scaling and units are reproduced as published; descriptions are our own.