Easy Modbus
  1. Home
  2. Modbus register maps
  3. Laumas
  4. WLIGHT weight indicator / transmitter (Modbus RTU)

Sensor (load-cell weight indicator) · Modbus register map

Laumas WLIGHT weight indicator / transmitter (Modbus RTU) Modbus register map

Updated 17 November 2026

Short answer

The WLIGHT is a compact load-cell weight indicator with RS-485. In Modbus RTU mode it offers a small register set: identification, a command register, a status word, gross/net/peak weight as 32-bit pairs, the division and unit setting, and the sample weight used for calibration.

This page lists 12 Modbus registers for the Laumas WLIGHT weight indicator / transmitter (Modbus RTU) — 2 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Laumas’s own free documentation (linked below) and checked against it.

Manufacturer
Laumas
Model
WLIGHT weight indicator / transmitter (Modbus RTU)
Equipment type
Sensor (load-cell weight indicator)
Registers
12 (2 writable)
Transport
Modbus RTU
Default unit ID
1
Default serial
9600 baud, 8N1
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
32-bit word order
ABCD high word first (big-endian)
Also known as
WLIGHT, W LIGHT
Source document
WLIGHT Installation and User Manual · version 1.03 · unofficial copy
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Laumas WLIGHT weight indicator / transmitter (Modbus RTU)

Integration in brief

Choose Modbus RTU in the serial menu, then read 40007-40013 with FC3 for status, gross, net and peak weight. Apply the sign bits and the division index. Write 7, 9 or 8 to 40006 for tare on, tare off and zero.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 6Status registerBITMAP16Status wordRead
HR 7Gross weightUINT32 ABCDGross weightRead
HR 9Net weightUINT32 ABCDNet weightRead
HR 13Divisions and units of measureUINT16Division index for decimalsRead
HR 5Command registerUINT16Command registerRead/write

Enable Modbus control & writes

Serial communication is disabled by default: select the Modbus RTU protocol in the serial menu, then address (1-99, default 1), baud (default 9600), parity (default none), stop bits (default 1).

Byte order & addressing

Network setup

Watch out for

Laumas WLIGHT weight indicator / transmitter (Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

12 of 12 shown
Laumas WLIGHT weight indicator / transmitter (Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
HR0doc 40001Firmware versionUINT16Read
HR1doc 40002Instrument typeUINT16Read
HR2doc 40003Year of manufactureUINT16Read
HR3doc 40004Serial numberUINT16Read
HR4doc 40005Active programUINT16Read
HR5doc 40006Command registerWrite a command code to run it.UINT16Read/write0 = No command; 7 = Semi-automatic tare on (net display); 8 = Semi-automatic zero; 9 = Semi-automatic tare off (gross display); 21 = Keypad lock; 22 = Keypad and display unlock; 23 = Keypad and display lock; 99 = Save data in EEPROM; 100 = Tare weight zero setting for calibration; 101 = Sample weight storage for calibration
HR6doc 40007Status registerWeight sign, stability and error flags.BITMAP16Readbit 0 = Load cell error; bit 1 = AD converter malfunction; bit 2 = Maximum weight exceeded by 9 divisions; bit 3 = Gross weight over 110% of full scale; bit 4 = Gross weight over 999999 or under -999999; bit 5 = Net weight over 999999 or under -999999; bit 7 = Gross weight negative sign; bit 8 = Net weight negative sign; bit 9 = Peak weight negative sign; bit 10 = Net display mode; bit 11 = Weight stable; bit 12 = Weight within +/- 1/4 division of zero
HR7doc 40008Gross weightMagnitude without decimal point; sign is status bit 7.UINT32ABCDRead
HR9doc 40010Net weightMagnitude without decimal point; sign is status bit 8.UINT32ABCDRead
HR11doc 40012Peak weightMagnitude without decimal point; sign is status bit 9.UINT32ABCDRead
HR13doc 40014Divisions and units of measureHigh byte = unit index, low byte = division index.UINT16Read
HR64doc 40065Sample weight for calibrationTest weight in divisions; use with command 101. Reads 0 after success.INT32ABCDRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Laumas WLIGHT weight indicator / transmitter (Modbus RTU)

What Modbus registers does the Laumas WLIGHT weight indicator / transmitter (Modbus RTU) have?

This map lists 12 registers: 12 holding registers. 2 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Laumas WLIGHT weight indicator / transmitter (Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Registers are printed 40001-40066; subtract 40001 for a 0-based client (the manual's own example: 40028 -> 27). The read example uses start address 0x0007 for gross weight at 40008.

What byte order does the Laumas WLIGHT weight indicator / transmitter (Modbus RTU) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Laumas WLIGHT weight indicator / transmitter (Modbus RTU)?

Start with HR 6 Status register (Status word); HR 7 Gross weight (Gross weight); HR 9 Net weight (Net weight); HR 13 Divisions and units of measure (Division index for decimals); HR 5 Command register (Command register).

How do I enable Modbus control of the Laumas WLIGHT weight indicator / transmitter (Modbus RTU)?

Serial communication is disabled by default: select the Modbus RTU protocol in the serial menu, then address (1-99, default 1), baud (default 9600), parity (default none), stop bits (default 1).

Where is the official Laumas WLIGHT weight indicator / transmitter (Modbus RTU) Modbus documentation?

The source is WLIGHT Installation and User Manual (version 1.03). Laumas doesn't publish it on its own website, so this map was re-typed from a free copy at https://www.massload.com/wp-content/uploads/2026/07/Laumas-WLIGHT_UserManual.pdf. It may be an older revision, so check it against the live unit.

More Laumas Modbus register maps

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: WLIGHT Installation and User Manual · version 1.03 · unofficial copy. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.