Laumas TLS weight transmitter with analog output (Modbus RTU) Modbus register map

Updated 17 November 2026

Short answer

The TLS is a single-channel load-cell transmitter with an analog output and RS-485. With the port set to Modbus RTU it gives gross, net and peak weight, a status word, two inputs and two outputs, two setpoints and the analog-output span as holding registers. Tare, zero, calibration and EEPROM saves are triggered by writing codes to one command register.

This page lists 20 Modbus registers for the Laumas TLS weight transmitter with analog output (Modbus RTU) — 9 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Laumas’s own free documentation (linked below) and checked against it.

Manufacturer
Laumas
Model
TLS weight transmitter with analog output (Modbus RTU)
Equipment type
Sensor (load-cell weight transmitter)
Registers
20 (9 writable)
Transport
Modbus RTU
Default unit ID
1
Default serial
9600 baud, 8N1
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
32-bit word order
ABCD high word first (big-endian)
Also known as
TLS, TLS 4-20mA, TLS 0-10V, CASTLTASTATEX
Source document
TLS Installation and User Manual · version 1.19 · unofficial copy
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Laumas TLS weight transmitter with analog output (Modbus RTU)

Integration in brief

Set the serial port to Modbus RTU, then read 40007-40013 with FC3: status word, gross, net and peak weight. Use the status sign bits and the division index (40014) to get the real value. Write 7, 9 and 8 to 40006 for tare on, tare off and zero.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 6Status registerBITMAP16Status wordRead
HR 7Gross weightUINT32 ABCDGross weightRead
HR 9Net weightUINT32 ABCDNet weightRead
HR 13Divisions and units of measureUINT16Division index for decimalsRead
HR 5Command registerUINT16Command registerWrite
HR 24InputsBITMAP16Digital inputsRead

Enable Modbus control & writes

In the serial communication menu choose the Modbus RTU protocol (communication is disabled by default), then set address (1-99, default 1), baud (default 9600), parity (default none) and stop bits (default 1).

Byte order & addressing

Network setup

Watch out for

Laumas TLS weight transmitter with analog output (Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

20 of 20 shown
Laumas TLS weight transmitter with analog output (Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
HR0doc 40001Firmware versionUINT16Read
HR1doc 40002Instrument typeUINT16Read
HR2doc 40003Year of manufactureUINT16Read
HR3doc 40004Serial numberUINT16Read
HR4doc 40005Active programUINT16Read
HR5doc 40006Command registerWrite a command code to run it.UINT16Write0 = No command; 7 = Semi-automatic tare on (net display); 8 = Semi-automatic zero; 9 = Semi-automatic tare off (gross display); 21 = Keypad lock; 22 = Keypad and display unlock; 23 = Keypad and display lock; 99 = Save data in EEPROM; 100 = Tare weight zero setting for calibration; 101 = Save first sample weight for calibration; 104 = Cancel real calibration; 106 = Add sample weight for calibration; 130 = Enable preset tare; 6811 = Write requested analog output current (value in registers 40122-40123); 6812 = Read requested analog output current into 40122-40123; 6813 = Write requested analog output voltage (value in registers 40122-40123); 6814 = Read requested analog output voltage into 40122-40123
HR6doc 40007Status registerWeight sign, stability and error flags.BITMAP16Readbit 0 = Load cell error; bit 1 = AD converter malfunction; bit 2 = Maximum weight exceeded by 9 divisions; bit 3 = Gross weight over 110% of full scale; bit 4 = Gross weight over 999999 or under -999999; bit 5 = Net weight over 999999 or under -999999; bit 7 = Gross weight negative sign; bit 8 = Net weight negative sign; bit 9 = Peak weight negative sign; bit 10 = Net display mode; bit 11 = Weight stable; bit 12 = Weight within +/- 1/4 division of zero
HR7doc 40008Gross weightMagnitude without decimal point; sign is status bit 7.UINT32ABCDRead
HR9doc 40010Net weightMagnitude without decimal point; sign is status bit 8.UINT32ABCDRead
HR11doc 40012Peak weightMagnitude without decimal point; sign is status bit 9.UINT32ABCDRead
HR13doc 40014Divisions and units of measureHigh byte = unit index, low byte = division index.UINT16Read
HR16doc 40017Setpoint 1Weight value without decimal point; RAM until command 99.INT32ABCDRead/write
HR18doc 40019Setpoint 2Weight value without decimal point; RAM until command 99.INT32ABCDRead/write
HR22doc 40023Hysteresis 2Subtracted from setpoint 2 for release.INT32ABCDRead/write
HR24doc 40025InputsBITMAP16Readbit 0 = Input 1 status; bit 1 = Input 2 status
HR25doc 40026OutputsWritable only for outputs configured for PLC control.BITMAP16Read/writebit 0 = Output 1 status; bit 1 = Output 2 status
HR36doc 40037Sample weight for calibrationTest weight in divisions; use with command 101/106. Reads 0 after success.INT32ABCDRead/write
HR42doc 40043Analog output zero weightWeight giving analog zero; save with command 99.INT32ABCDRead/write
HR44doc 40045Analog output full-scale weightWeight giving analog full scale; save with command 99.INT32ABCDRead/write
HR121doc 40122Exchange register 1-2 (analog value)mA or V x 10000 for commands 6811-6814 (REGISTER 1 = H, REGISTER 2 = L).UINT32ABCD× 0.0001Read/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Laumas TLS weight transmitter with analog output (Modbus RTU)

What Modbus registers does the Laumas TLS weight transmitter with analog output (Modbus RTU) have?

This map lists 20 registers: 20 holding registers. 9 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Laumas TLS weight transmitter with analog output (Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The manual prints registers as 40001-40131 and says to subtract 40001 for 0-based clients (40028 -> 27). Its read example asks for start address 0x0007 to read gross weight at 40008, which confirms it.

What byte order does the Laumas TLS weight transmitter with analog output (Modbus RTU) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Laumas TLS weight transmitter with analog output (Modbus RTU)?

Start with HR 6 Status register (Status word); HR 7 Gross weight (Gross weight); HR 9 Net weight (Net weight); HR 13 Divisions and units of measure (Division index for decimals); HR 5 Command register (Command register); HR 24 Inputs (Digital inputs).

How do I enable Modbus control of the Laumas TLS weight transmitter with analog output (Modbus RTU)?

In the serial communication menu choose the Modbus RTU protocol (communication is disabled by default), then set address (1-99, default 1), baud (default 9600), parity (default none) and stop bits (default 1).

Where is the official Laumas TLS weight transmitter with analog output (Modbus RTU) Modbus documentation?

The source is TLS Installation and User Manual (version 1.19). Laumas doesn't publish it on its own website, so this map was re-typed from a free copy at https://www.massload.com/wp-content/uploads/2026/08/TLS_UserManual.pdf. It may be an older revision, so check it against the live unit.

More Laumas Modbus register maps

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: TLS Installation and User Manual · version 1.19 · unofficial copy. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.