Variable frequency drive · Modbus register map
Inovance MD200 series compact AC drive Modbus register map
Updated 19 November 2026
Inovance's compact general-purpose drive for small machines, fans and pumps. Its RS-485 port speaks Modbus RTU. Speed is written as a signed percentage to 1000H, run commands go to 2000H, status and fault sit at 3000H and 8000H, and every parameter (F/A groups at FxxxH/AxxxH, U0 monitors at 70xxH) has its own hex address. This map covers the control registers, the main U0 monitors and the FD communication parameters.
This page lists 46 Modbus registers for the Inovance MD200 series compact AC drive — 16 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Inovance’s own free documentation (linked below) and checked against it.
- Manufacturer
- Inovance
- Model
- MD200 series compact AC drive
- Equipment type
- Variable frequency drive
- Registers
- 46 (16 writable)
- Transport
- Modbus RTU
- Default unit ID
- 1
- Default serial
- 9600 baud, 8N2
- Documented addressing
- hexadecimal, 0-based
- Also known as
- MD200, MD200T, MD200S, MD200-NC, Inovance MD200
Integration notes: Inovance MD200 series compact AC drive
Set F0-02 = 2 and F0-03 = 9, then write the speed as a signed percentage of F0-10 to 1000H (10000 = 100.00 %) and a run code to 2000H. Poll 3000H for run state, 8000H for faults and 7000H-7006H for frequency, voltage, current, power and torque.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| HR 8192 | Control command | UINT16 | Run / stop / reset command | Write |
| HR 4096 | Communication setting | INT16 | Speed reference as % of max frequency | Write |
| HR 12288 | AC drive running status | UINT16 | Forward / reverse / stopped | Read |
| HR 32768 | AC drive fault code | UINT16 | Fault code | Read |
| HR 28672 | U0-00 Running frequency | UINT16 | Running frequency | Read |
| HR 28676 | U0-04 Output current | UINT16 | Output current | Read |
| HR 28674 | U0-02 Bus voltage | UINT16 | DC bus voltage | Read |
Enable Modbus control & writes
F0-02 = 2 (communication) accepts run commands from 2000H; F0-03 = 9 (communication) makes 1000H the main frequency. FD-00..FD-02 set baud, format and address; FD-05 = 1 selects standard Modbus.
Communication loss & watchdog
FD-04 sets a communication timeout (0.0 s = off); when exceeded the drive reports a communication error (Err16).
Byte order & addressing
- 1000H is a percentage, not Hz: 10000 = +100.00 % of F0-10, negative values reverse.
- Output current resolution over Modbus is 0.01 A by default, 0.1 A when FD-06 = 1.
- Default serial format is 8-N-2 (FD-01 = 0), not 8-N-1.
Network setup
- FD-02 address (default 1), FD-00 ones digit = baud (default 5 = 9600 bit/s), FD-01 = data format.
- Restore factory settings over Modbus by writing the user password to 1F00H, then 1 to 1F01H.
Watch out for
- Repeated parameter writes to FxxxH go to EEPROM; use the 0xxxH RAM alias for values that change often.
Inovance MD200 series compact AC drive Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| HR | 4096doc 1000H | Communication setting | -10000 to 10000 = -100.00 to 100.00 % of F0-10 (frequency) or the target quantity. | INT16 | × 0.01 | % | Write | ||
| HR | 7936doc 1F00H | Password verification | FP-00 user password. Write the correct password here before writing 1F01H; a read that returns 8888H means verification passed. | UINT16 | Read/write | ||||
| HR | 7937doc 1F01H | Parameter initialization | UINT16 | Write | 0 = No action; 1 = Restore factory settings (excluding motor parameters); 2 = Clear records; 4 = Back up current user parameters; 20 = Conveyor belt industry macro; 21 = Fan industry macro; 501 = Restore user backup parameters | ||||
| HR | 8192doc 2000 | Control command | Needs F0-02 = 2. | UINT16 | Write | 1 = Forward run; 2 = Reverse run; 3 = Forward jog; 4 = Reverse jogging; 5 = Coast to stop; 6 = Decelerate to stop; 7 = Fault reset | |||
| HR | 8193doc 2001 | DO control | Relay must be assigned function 20 (communication control). | BITMAP16 | Write | bit 2 = Relay 1 output control | |||
| HR | 8194doc 2002 | AO control | 0-7FFF = 0-100 %; AO must be assigned function 12. | UINT16 | Write | ||||
| HR | 12288doc 3000H | AC drive running status | UINT16 | Read | 1 = Forward run; 2 = Reverse run; 3 = Stop | ||||
| HR | 28672doc U0-00 (0x7000) | U0-00 Running frequency | UINT16 | × 0.01 | Hz | Read | |||
| HR | 28673doc U0-01 (0x7001) | U0-01 Frequency reference | UINT16 | × 0.01 | Hz | Read | |||
| HR | 28674doc U0-02 (0x7002) | U0-02 Bus voltage | UINT16 | × 0.1 | V | Read | |||
| HR | 28675doc U0-03 (0x7003) | U0-03 Output voltage | UINT16 | V | Read | ||||
| HR | 28676doc U0-04 (0x7004) | U0-04 Output current | 0.01 A with FD-06 = 0 (default); 0.1 A when FD-06 = 1. | UINT16 | × 0.01 | A | Read | ||
| HR | 28677doc U0-05 (0x7005) | U0-05 Output power | INT16 | × 0.1 | kW | Read | |||
| HR | 28678doc U0-06 (0x7006) | U0-06 Output torque | -200.0 to 200.0 %. | INT16 | × 0.1 | % | Read | ||
| HR | 28679doc U0-07 (0x7007) | U0-07 DI state | BITMAP16 | Read | |||||
| HR | 28680doc U0-08 (0x7008) | U0-08 DO state | BITMAP16 | Read | |||||
| HR | 28681doc U0-09 (0x7009) | U0-09 AI1 voltage | -10.57 to 10.57 V. | INT16 | × 0.01 | V | Read | ||
| HR | 28683doc U0-11 (0x700B) | U0-11 External panel potentiometer voltage | INT16 | × 0.01 | V | Read | |||
| HR | 28687doc U0-15 (0x700F) | U0-15 PID reference | UINT16 | % | Read | ||||
| HR | 28688doc U0-16 (0x7010) | U0-16 PID feedback | UINT16 | % | Read | ||||
| HR | 28689doc U0-17 (0x7011) | U0-17 PLC stage | UINT16 | Read | |||||
| HR | 28690doc U0-18 (0x7012) | U0-18 Pulse input frequency | UINT16 | × 0.01 | kHz | Read | |||
| HR | 28692doc U0-20 (0x7014) | U0-20 Remaining running time | UINT16 | × 0.1 | min | Read | |||
| HR | 28693doc U0-21 (0x7015) | U0-21 AI1 voltage before correction | INT16 | × 0.001 | V | Read | |||
| HR | 28697doc U0-25 (0x7019) | U0-25 Current power-on time | UINT16 | min | Read | ||||
| HR | 28698doc U0-26 (0x701A) | U0-26 Current running time | UINT16 | × 0.1 | min | Read | |||
| HR | 28699doc U0-27 (0x701B) | U0-27 Pulse input frequency | UINT16 | Hz | Read | ||||
| HR | 28700doc U0-28 (0x701C) | U0-28 Communication setting | Read-back of the 1000H value. | INT16 | × 0.01 | % | Read | ||
| HR | 28702doc U0-30 (0x701E) | U0-30 Main frequency X | INT16 | × 0.01 | Hz | Read | |||
| HR | 28703doc U0-31 (0x701F) | U0-31 Auxiliary frequency Y | INT16 | × 0.01 | Hz | Read | |||
| HR | 28731doc U0-59 (0x703B) | U0-59 Frequency reference percentage | INT16 | × 0.01 | % | Read | |||
| HR | 28732doc U0-60 (0x703C) | U0-60 Running frequency percentage | INT16 | × 0.01 | % | Read | |||
| HR | 28734doc U0-62 (0x703E) | U0-62 Current fault code | 0-99. | UINT16 | Read | ||||
| HR | 28742doc U0-70 (0x7046) | U0-70 Motor speed | -32767 to 32767 rpm. | INT16 | rpm | Read | |||
| HR | 32768doc 8000H | AC drive fault code | Same codes as F9-14. | UINT16 | Read | 0 = No fault; 1 = Reserved; 2 = Overcurrent during acceleration (Err02); 3 = Overcurrent during deceleration (Err03); 4 = Overcurrent at constant speed (Err04); 5 = Overvoltage during acceleration (Err05); 6 = Overcurrent during deceleration (Err06) [as printed]; 7 = Overvoltage at constant speed (Err07); 8 = Pre-charge resistor overload (Err08); 9 = Undervoltage (Err09); 10 = AC drive overload (Err10); 11 = Motor overload (Err11); 12 = Input phase loss (Err12); 13 = Output phase loss (Err13); 14 = Module overheat (Err14); 15 = External fault (Err15); 16 = Communication error (Err16); 18 = Current detection error (Err18); 19 = Motor auto-tuning error (Err19); 21 = Parameter read/write error (Err21); 23 = Motor short-circuited to ground (Err23); 26 = Running time reached (Err26); 27 = User-defined fault 1; 28 = User-defined fault 2; 29 = Power-on time reached (Err29); 30 = Load loss (Err30); 31 = PID feedback loss during running (Err31); 40 = Fast current limit timeout (Err40); 42 = Excessive speed deviation (Err42); 55 = Slave fault under master/slave control (Err55) | |||
| HR | 61442doc F0-02 (0xF002) | F0-02 Command source | Set 2 so 2000H commands are accepted. | UINT16 | Read/write | 0 = Operation panel; 1 = Terminal; 2 = Communication | |||
| HR | 61443doc F0-03 (0xF003) | F0-03 Main frequency source X | Set 9 so 1000H sets the speed. | UINT16 | Read/write | 0 = Digital setting (non-retentive); 1 = Digital setting (retentive); 2 = AI1; 3 = External operating panel potentiometer; 5 = Pulse input; 6 = Multi-reference; 7 = Simple PLC; 8 = PID; 9 = Communication | |||
| HR | 61450doc F0-10 (0xF00A) | F0-10 Max. frequency | 50.00-500.00 Hz; 1000H is a percentage of this. | UINT16 | × 0.01 | Hz | Read/write | ||
| HR | 63758doc F9-14 (0xF90E) | F9-14 Type of the 1st fault | Most recent fault; same codes as 8000H. | UINT16 | Read | 0 = No fault; 1 = Reserved; 2 = Overcurrent during acceleration (Err02); 3 = Overcurrent during deceleration (Err03); 4 = Overcurrent at constant speed (Err04); 5 = Overvoltage during acceleration (Err05); 6 = Overcurrent during deceleration (Err06) [as printed]; 7 = Overvoltage at constant speed (Err07); 8 = Pre-charge resistor overload (Err08); 9 = Undervoltage (Err09); 10 = AC drive overload (Err10); 11 = Motor overload (Err11); 12 = Input phase loss (Err12); 13 = Output phase loss (Err13); 14 = Module overheat (Err14); 15 = External fault (Err15); 16 = Communication error (Err16); 18 = Current detection error (Err18); 19 = Motor auto-tuning error (Err19); 21 = Parameter read/write error (Err21); 23 = Motor short-circuited to ground (Err23); 26 = Running time reached (Err26); 27 = User-defined fault 1; 28 = User-defined fault 2; 29 = Power-on time reached (Err29); 30 = Load loss (Err30); 31 = PID feedback loss during running (Err31); 40 = Fast current limit timeout (Err40); 42 = Excessive speed deviation (Err42); 55 = Slave fault under master/slave control (Err55) | |||
| HR | 64768doc FD-00 (0xFD00) | FD-00 Baud rate | Ones digit = Modbus rate: 0 300, 1 600, 2 1200, 3 2400, 4 4800, 5 9600, 6 19200, 7 38400, 8 57600, 9 115200 bit/s. Thousands digit = CANlink. Default 5005. | UINT16 | Read/write | ||||
| HR | 64769doc FD-01 (0xFD01) | FD-01 Modbus data format | UINT16 | Read/write | 0 = No check (8-N-2); 1 = Even parity (8-E-1); 2 = Odd parity (8-O-1); 3 = No check (8-N-1) | ||||
| HR | 64770doc FD-02 (0xFD02) | FD-02 Local address | 0-247, default 1. | UINT16 | Read/write | ||||
| HR | 64771doc FD-03 (0xFD03) | FD-03 Modbus response delay | 0-20 ms, default 2. | UINT16 | ms | Read/write | |||
| HR | 64772doc FD-04 (0xFD04) | FD-04 Communication timeout | 0.0-60.0 s; 0.0 = off. | UINT16 | × 0.1 | s | Read/write | ||
| HR | 64773doc FD-05 (0xFD05) | FD-05 Data transmission protocol | Default 1. | UINT16 | Read/write | 0 = Non-standard Modbus; 1 = Standard Modbus | |||
| HR | 64774doc FD-06 (0xFD06) | FD-06 Current resolution over communication | Sets the scale of U0-04 output current. | UINT16 | Read/write | 0 = 0.01 A (drives up to 55 kW); 1 = 0.1 A |
Notes on this map
- All registers are single 16-bit words. Scales follow the decimals printed in each parameter's range; the guide's read example returns 13 88 (5000) for F0-10 = 50.00 Hz.
- To write F-group parameters without storing them in EEPROM, replace the leading F with 0 (F0-16 -> 0010H); A-group parameters use 4x instead of Ax.
- Left out: U0-14 and U0-19 (decimal places set by F7-12), U0-61 (drive state code, no value table), U0-69 (printed Int16 with a 0.00-655.35 Hz range), single-phase-only monitors (U0-12, U0-13, U0-24, U0-35, U0-65, U0-78) and reserved rows.
- Fault code 6 is printed with the same text as code 3 ('Overcurrent during deceleration'), so its real meaning is unclear. Reserved fault codes are omitted.
- 2000H, 2001H, 2002H and 1000H are write-only; 2001H bits other than relay 1 are reserved on MD200.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Inovance MD200 series compact AC drive
What Modbus registers does the Inovance MD200 series compact AC drive have?
This map lists 46 registers: 46 holding registers. 16 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Inovance MD200 series compact AC drive Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Addresses are hex and go on the wire unchanged: the guide reads F0-10 with 01 03 F0 0A ..., writes AC-16 with 01 06 4C 10 ... and sets the frequency with 01 06 10 00 .... A parameter's address is its group code (F0H-FFH, A0H-AFH, 70H-7FH for U0-UF) followed by its number in hex.
What are the minimum Modbus registers to integrate the Inovance MD200 series compact AC drive?
Start with HR 8192 Control command (Run / stop / reset command); HR 4096 Communication setting (Speed reference as % of max frequency); HR 12288 AC drive running status (Forward / reverse / stopped); HR 32768 AC drive fault code (Fault code); HR 28672 U0-00 Running frequency (Running frequency); HR 28676 U0-04 Output current (Output current); HR 28674 U0-02 Bus voltage (DC bus voltage).
How do I enable Modbus control of the Inovance MD200 series compact AC drive?
F0-02 = 2 (communication) accepts run commands from 2000H; F0-03 = 9 (communication) makes 1000H the main frequency. FD-00..FD-02 set baud, format and address; FD-05 = 1 selects standard Modbus.
What happens when the Inovance MD200 series compact AC drive loses Modbus communication?
FD-04 sets a communication timeout (0.0 s = off); when exceeded the drive reports a communication error (Err16).
Where is the official Inovance MD200 series compact AC drive Modbus documentation?
The source is MD200 Series General-Purpose AC Drive User Guide (19012113 C02), revision 2023-01, published free by Inovance at https://inovance.eu/fileadmin/downloads/Manuals/EN/MD200/MD200_User_Guide_EN_C02_19012113.PDF.
More Inovance Modbus register maps
Other variable frequency drives register maps
- Variable frequency drive
INVT Goodrive10 (GD10) mini VFD
INVT Goodrive10 mini drives using the built-in RS-485 Modbus RTU port, per the GD10 VFD manual V2.9 (chapter 7).
Also known as: GD10, Goodrive10, GD10 mini VFD - Variable frequency drive
INVT Goodrive350A (GD350A) high-performance multifunction VFD
INVT Goodrive350A drives using the built-in RS-485 Modbus RTU port, per the GD350A manual V1.3 (chapter 9).
Also known as: GD350A, Goodrive350A, GD350A series - Variable frequency drive
Lovato Electric VT1 series variable speed drives (Modbus RTU / ASCII)
Lovato VT1 series drives on the built-in RS-485 port, per communication manual I646 GB I 02 21 (Modbus part).
Also known as: VT1, Lovato VT1, VT1 series - Variable frequency drive
NORD Drivesystems SK 540E / SK 545E frequency inverter (built-in Modbus RTU)
NORD SK 500E-series inverters from SK 540E up (SK 540E, SK 545E) on the RS485 interface, per supplementary manual BU 0050 (GB-3111).
Also known as: SK 540E, SK 545E, SK 54xE, NORDAC SK 500E series (SK 540E and above) - Actuator / valve driver (I/O module, 3 analog outputs)
Seneca Z-3AO 3-channel analog output module
Seneca Z-3AO DIN-rail module with three voltage/current outputs and RS-485 Modbus RTU, per user manual MI00260-2-EN.
Also known as: Z-3AO - Variable frequency drive
TECO-Westinghouse E510 Compact (E510N1) inverter (Modbus RTU/ASCII)
TECO-Westinghouse E510 Compact (E510N1) inverters with the built-in RS-485 port (CON2), per communication addendum DOCUMENT-TECO-E510N1-AC002 Ver01 (2017-08).
Also known as: E510N1, E510s, TECO E510 Compact
All variable frequency drives Modbus register maps →
Source: MD200 Series General-Purpose AC Drive User Guide · 19012113 C02 · rev. 2023-01. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.