Energy meter · Modbus register map

Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) Modbus register map

Updated 17 November 2026

Short answer

The DTS family are compact DIN-rail, panel and socket energy sub-meters and transducers for single-phase, three-phase and DC circuits. Every value is a signed 32-bit integer in two holding registers, low word first. This map covers voltages, currents, frequency, power, power factor, unbalance, nett and split energy counters, identity and CT/PT ratio registers, and the RS-485 settings.

This page lists 78 Modbus registers for the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) — 8 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Measurlogic’s own free documentation (linked below) and checked against it.

Manufacturer
Measurlogic
Model
DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC)
Equipment type
Energy meter
Registers
78 (8 writable)
Transport
Modbus RTU, Modbus TCP
Default unit ID
100
Documented addressing
1-based (subtract 1 for the wire address)
32-bit word order
CDAB low word first (word-swapped)
Also known as
DTS 101, DTS 105, DTS 305, DTS 310, DTS SMX, DTS SKT, DTS DC
Source document
DTS Modbus Map · Version 2.7U · rev. 2012-10-17 · unofficial copy
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC)

Integration in brief

Read holding registers in CDAB 32-bit pairs at address 100 (default). Read EnerPowDivider (16045) first and scale power and energy with raw x divider x 0.001.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 11000Voltage_LN_1INT32 CDABVoltage L1-NRead
HR 11024Current_1INT32 CDABCurrent 1Read
HR 11054PowerP_TotalINT32 CDABTotal active power (raw)Read
HR 14006EnergyP_TotalINT32 CDABTotal nett active energy (raw)Read
HR 16044EnerPowDividerINT32 CDABEnerPowDividerRead/write

Enable Modbus control & writes

Modbus is built in (RS-485 RTU or Ethernet TCP depending on model). Communication parameters and address are normally set with Measurlogic's DTSConfig software.

Byte order & addressing

Network setup

Watch out for

Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

78 of 78 shown
Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
HR10002doc 10003DTS_SerialNumberINT32CDABRead
HR10008doc 10009DTS_FW_VersionINT32CDAB× 0.0001Read
HR10014doc 10015DTS_Model_IDINT32CDABRead
HR11000doc 11001Voltage_LN_1On DTS DC meters 11001 is Voltage_DC.INT32CDAB× 0.1VRead
HR11002doc 11003Voltage_LN_2INT32CDAB× 0.1VRead
HR11004doc 11005Voltage_LN_3INT32CDAB× 0.1VRead
HR11006doc 11007Voltage_LN_AverageINT32CDAB× 0.1VRead
HR11008doc 11009Voltage_LL_12INT32CDAB× 0.1VRead
HR11010doc 11011Voltage_LL_23INT32CDAB× 0.1VRead
HR11012doc 11013Voltage_LL_31INT32CDAB× 0.1VRead
HR11014doc 11015Voltage_LL_AverageINT32CDAB× 0.1VRead
HR11024doc 11025Current_1On DTS DC meters 11025 is Current_DC.INT32CDAB× 0.001ARead
HR11026doc 11027Current_2INT32CDAB× 0.001ARead
HR11028doc 11029Current_3INT32CDAB× 0.001ARead
HR11030doc 11031Current_AverageINT32CDAB× 0.001ARead
HR11032doc 11033Current_TotalINT32CDAB× 0.001ARead
HR11034doc 11035Current_NeutralINT32CDAB× 0.001ARead
HR11040doc 11041Frequency_1INT32CDAB× 0.01HzRead
HR11042doc 11043Frequency_2INT32CDAB× 0.01HzRead
HR11044doc 11045Frequency_3INT32CDAB× 0.01HzRead
HR11046doc 11047Frequency_AverageINT32CDAB× 0.01HzRead
HR11048doc 11049PowerP_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get W (11049 is Power_DC on DC meters).INT32CDABRead
HR11050doc 11051PowerP_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get W.INT32CDABRead
HR11052doc 11053PowerP_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get W.INT32CDABRead
HR11054doc 11055PowerP_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get W.INT32CDABRead
HR11056doc 11057PowerS_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get VA.INT32CDABRead
HR11058doc 11059PowerS_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get VA.INT32CDABRead
HR11060doc 11061PowerS_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get VA.INT32CDABRead
HR11062doc 11063PowerS_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get VA.INT32CDABRead
HR11064doc 11065PowerQ_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get var.INT32CDABRead
HR11066doc 11067PowerQ_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get var.INT32CDABRead
HR11068doc 11069PowerQ_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get var.INT32CDABRead
HR11070doc 11071PowerQ_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get var.INT32CDABRead
HR11124doc 11125ACosPF_1Power factor angle.INT32CDAB× 0.1°Read
HR11126doc 11127ACosPF_2Power factor angle.INT32CDAB× 0.1°Read
HR11128doc 11129ACosPF_3Power factor angle.INT32CDAB× 0.1°Read
HR11130doc 11131ACosPF_OverallPower factor angle.INT32CDAB× 0.1°Read
HR11140doc 11141Voltage_Unbalance_LN_1INT32CDAB× 0.01%Read
HR11142doc 11143Voltage_Unbalance_LN_2INT32CDAB× 0.01%Read
HR11144doc 11145Voltage_Unbalance_LN_3INT32CDAB× 0.01%Read
HR11146doc 11147Voltage_Unbalance_LN_WorstINT32CDAB× 0.01%Read
HR11148doc 11149Voltage_Unbalance_LL_12INT32CDAB× 0.01%Read
HR11150doc 11151Voltage_Unbalance_LL_23INT32CDAB× 0.01%Read
HR11152doc 11153Voltage_Unbalance_LL_31INT32CDAB× 0.01%Read
HR11154doc 11155Voltage_Unbalance_LL_WorstINT32CDAB× 0.01%Read
HR11156doc 11157Current_Unbalance_1INT32CDAB× 0.01%Read
HR11158doc 11159Current_Unbalance_2INT32CDAB× 0.01%Read
HR11160doc 11161Current_Unbalance_3INT32CDAB× 0.01%Read
HR11162doc 11163Current_Unbalance_WorstINT32CDAB× 0.01%Read
HR11256doc 11257DemandP_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get W.INT32CDABRead
HR14000doc 14001EnergyP_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get Wh; nett counters are signed (export negative).INT32CDABRead
HR14002doc 14003EnergyP_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get Wh; nett counters are signed (export negative).INT32CDABRead
HR14004doc 14005EnergyP_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get Wh; nett counters are signed (export negative).INT32CDABRead
HR14006doc 14007EnergyP_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get Wh; nett counters are signed (export negative).INT32CDABRead
HR14008doc 14009EnergyS_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get VAh; nett counters are signed (export negative).INT32CDABRead
HR14010doc 14011EnergyS_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get VAh; nett counters are signed (export negative).INT32CDABRead
HR14012doc 14013EnergyS_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get VAh; nett counters are signed (export negative).INT32CDABRead
HR14014doc 14015EnergyS_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get VAh; nett counters are signed (export negative).INT32CDABRead
HR14016doc 14017EnergyQ_1Raw; multiply by EnerPowDivider (16045) x 0.001 to get varh; nett counters are signed (export negative).INT32CDABRead
HR14018doc 14019EnergyQ_2Raw; multiply by EnerPowDivider (16045) x 0.001 to get varh; nett counters are signed (export negative).INT32CDABRead
HR14020doc 14021EnergyQ_3Raw; multiply by EnerPowDivider (16045) x 0.001 to get varh; nett counters are signed (export negative).INT32CDABRead
HR14022doc 14023EnergyQ_TotalRaw; multiply by EnerPowDivider (16045) x 0.001 to get varh; nett counters are signed (export negative).INT32CDABRead
HR14024doc 14025EnergyP_Total_ImpRaw; multiply by EnerPowDivider (16045) x 0.001 to get Wh.INT32CDABRead
HR14026doc 14027EnergyP_Total_ExpRaw; multiply by EnerPowDivider (16045) x 0.001 to get Wh.INT32CDABRead
HR14028doc 14029EnergyQ_Total_ImpRaw; multiply by EnerPowDivider (16045) x 0.001 to get varh.INT32CDABRead
HR14030doc 14031EnergyQ_Total_ExpRaw; multiply by EnerPowDivider (16045) x 0.001 to get varh.INT32CDABRead
HR14080doc 14081GeneralCounter1General input pulse counter.INT32CDABRead
HR14082doc 14083GeneralCounter2General input pulse counter.INT32CDABRead
HR14084doc 14085GeneralCounter3General input pulse counter.INT32CDABRead
HR14086doc 14087GeneralCounter4General input pulse counter.INT32CDABRead
HR16000doc 16001VoltagePrimaryPT primary.INT32CDAB× 0.1VRead/write
HR16002doc 16003VoltageSecondaryPT secondary.INT32CDAB× 0.1VRead/write
HR16008doc 16009CurrentPrimaryCT primary.INT32CDAB× 0.001ARead/write
HR16010doc 16011CurrentSecondaryCT secondary.INT32CDAB× 0.001ARead/write
HR16044doc 16045EnerPowDividerPower/energy resolution divider; default 100 = 0.1 W.INT32CDABRead/write
HR16118doc 16119Rem_BaudrateRS-485 baud rate (9600 or 19200).INT32CDABRead/write
HR16120doc 16121Rem_Parity/DataBits/StopBitsPacked bytes: parity (0 none, 1 odd, 2 even), data bits, stop bits, reserved.INT32CDABRead/write
HR16122doc 16123Rem_AddressRS-485 slave address 1-247.INT32CDABRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC)

What Modbus registers does the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) have?

This map lists 78 registers: 78 holding registers. 8 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers 1-based (subtract 1 for the wire address). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Section 2.1.1 says the published addresses are 1-based in the 4x region; subtract 1 for the wire address (Voltage_LN_1 11001 -> 11000). Some masters want the 4 prefix (411001).

What byte order does the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) use for 32-bit values?

Multi-register values in this map use CDAB (low word first (word-swapped)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC)?

Start with HR 11000 Voltage_LN_1 (Voltage L1-N); HR 11024 Current_1 (Current 1); HR 11054 PowerP_Total (Total active power (raw)); HR 14006 EnergyP_Total (Total nett active energy (raw)); HR 16044 EnerPowDivider (EnerPowDivider).

How do I enable Modbus control of the Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC)?

Modbus is built in (RS-485 RTU or Ethernet TCP depending on model). Communication parameters and address are normally set with Measurlogic's DTSConfig software.

Where is the official Measurlogic DTS family energy sub-meters (DTS 101/105/305/310/SMX/SKT/DC) Modbus documentation?

The source is DTS Modbus Map (Version 2.7U), revision 2012-10-17. Measurlogic doesn't publish it on its own website, so this map was re-typed from a free copy at https://cdn.logic-control.com/docs/measurlogic/Measurlogic%20DTS%20Modbus%20Map%20V2.7U.pdf. It may be an older revision, so check it against the live unit.

Other power & energy meters register maps

All power & energy meters Modbus register maps →

Source: DTS Modbus Map · Version 2.7U · rev. 2012-10-17 · unofficial copy. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.