Easy Modbus
  1. Home
  2. Modbus register maps
  3. Rishabh Instruments
  4. RISH EM DC 6001 / 6002 multi-channel DC energy meter

Energy meter (DC) · Modbus register map

Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter Modbus register map

Updated 17 November 2026

Short answer

The RISH EM DC 6001/6002 is a 96 x 96 mm programmable DC energy meter with one voltage input and up to four shunt current channels. Modbus RTU on RS-485 returns each value as a 32-bit float. This map covers voltage, per-channel current, power, import/export energy and ampere-hours, demands and min/max values, plus the main setup registers.

This page lists 223 Modbus registers for the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter — 24 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Rishabh Instruments’s own free documentation (linked below) and checked against it.

Manufacturer
Rishabh Instruments
Model
RISH EM DC 6001 / 6002 multi-channel DC energy meter
Equipment type
Energy meter (DC)
Registers
223 (24 writable)
Transport
Modbus RTU
Default unit ID
1
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
32-bit word order
ABCD high word first (big-endian)
Also known as
RISH EM DC 6001, RISH EM DC 6002, EM DC 6001, EM DC 6002
Source document
RISH EM DC Interface Definition · 2-60-006-00-00627 Rev. 0 · rev. 2015-10
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter

Integration in brief

Read measured values with FC04 (or FC03 at the 4X copies) in pairs of registers and decode them as ABCD floats. Settings are floats too and are written with FC16.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 0VoltageFLOAT32 ABCDDC voltageRead
IR 2Current Ch1FLOAT32 ABCDChannel 1 currentRead
IR 10Power Ch1FLOAT32 ABCDChannel 1 powerRead
IR 18Total Import PowerFLOAT32 ABCDTotal import powerRead
IR 38Total Import EnergyFLOAT32 ABCDTotal import energyRead
IR 40Total Export EnergyFLOAT32 ABCDTotal export energyRead

Enable Modbus control & writes

Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.

Byte order & addressing

Network setup

Watch out for

Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

223 of 223 shown
Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR0doc 30001VoltageFLOAT32ABCDVRead
IR2doc 30003Current Ch1FLOAT32ABCDRead
IR4doc 30005Current Ch2FLOAT32ABCDRead
IR6doc 30007Current Ch3FLOAT32ABCDRead
IR8doc 30009Current Ch4FLOAT32ABCDRead
IR10doc 30011Power Ch1FLOAT32ABCDRead
IR12doc 30013Power Ch2FLOAT32ABCDRead
IR14doc 30015Power Ch3FLOAT32ABCDRead
IR16doc 30017Power Ch4FLOAT32ABCDRead
IR18doc 30019Total Import PowerFLOAT32ABCDRead
IR20doc 30021Total export PowerFLOAT32ABCDRead
IR22doc 30023Energy Imp Ch1FLOAT32ABCDRead
IR24doc 30025Energy Imp Ch2FLOAT32ABCDRead
IR26doc 30027Energy Imp Ch3FLOAT32ABCDRead
IR28doc 30029Energy Imp Ch4FLOAT32ABCDRead
IR30doc 30031Energy Exp Ch1FLOAT32ABCDRead
IR32doc 30033Energy Exp Ch2FLOAT32ABCDRead
IR34doc 30035Energy Exp Ch3FLOAT32ABCDRead
IR36doc 30037Energy Exp Ch4FLOAT32ABCDRead
IR38doc 30039Total Import EnergyFLOAT32ABCDRead
IR40doc 30041Total Export EnergyFLOAT32ABCDRead
IR58doc 30059Amp Hour Imp Ch1FLOAT32ABCDRead
IR60doc 30061Amp Hour Imp Ch2FLOAT32ABCDRead
IR62doc 30063Amp Hour Imp Ch3FLOAT32ABCDRead
IR64doc 30065Amp Hour Imp Ch4FLOAT32ABCDRead
IR66doc 30067Amp Hour Exp Ch1FLOAT32ABCDRead
IR68doc 30069Amp Hour Exp Ch2FLOAT32ABCDRead
IR70doc 30071Amp Hour Exp Ch3FLOAT32ABCDRead
IR72doc 30073Amp Hour Exp Ch4FLOAT32ABCDRead
IR74doc 30075Total Import AHFLOAT32ABCDRead
IR76doc 30077Total Export AHFLOAT32ABCDRead
IR78doc 30079Import Power Demand Ch1FLOAT32ABCDRead
IR80doc 30081Import Power Demand Ch2FLOAT32ABCDRead
IR82doc 30083Import Power Demand Ch3FLOAT32ABCDRead
IR84doc 30085Import Power Demand Ch4FLOAT32ABCDRead
IR86doc 30087Export Power Demand Ch1FLOAT32ABCDRead
IR88doc 30089Export Power Demand Ch2FLOAT32ABCDRead
IR90doc 30091Export Power Demand Ch3FLOAT32ABCDRead
IR92doc 30093Export Power Demand Ch4FLOAT32ABCDRead
IR94doc 30095Total Import Power DemandFLOAT32ABCDRead
IR96doc 30097Total Export Power DemandFLOAT32ABCDRead
IR98doc 30099Import Current Demand Ch1FLOAT32ABCDRead
IR100doc 30101Import Current Demand Ch2FLOAT32ABCDRead
IR102doc 30103Import Current Demand Ch3FLOAT32ABCDRead
IR104doc 30105Import Current Demand Ch4FLOAT32ABCDRead
IR106doc 30107Export Current Demand Ch1FLOAT32ABCDRead
IR108doc 30109Export Current Demand Ch2FLOAT32ABCDRead
IR110doc 30111Export Current Demand Ch3FLOAT32ABCDRead
IR112doc 30113Export Current Demand Ch4FLOAT32ABCDRead
IR114doc 30115Total Import Current DemandFLOAT32ABCDRead
IR116doc 30117Total Export Current DemandFLOAT32ABCDRead
IR118doc 30119Max VoltageFLOAT32ABCDRead
IR120doc 30121Min VoltageFLOAT32ABCDRead
IR122doc 30123Max Current Ch1FLOAT32ABCDRead
IR124doc 30125Max Current Ch2FLOAT32ABCDRead
IR126doc 30127Max Current Ch3FLOAT32ABCDRead
IR128doc 30129Max Current Ch4FLOAT32ABCDRead
IR130doc 30131Min Current Ch1FLOAT32ABCDRead
IR132doc 30133Min Current Ch2FLOAT32ABCDRead
IR134doc 30135Min Current Ch3FLOAT32ABCDRead
IR136doc 30137Min Current Ch4FLOAT32ABCDRead
IR138doc 30139Max Import Power Demand Ch1FLOAT32ABCDRead
IR140doc 30141Max Import Power Demand Ch2FLOAT32ABCDRead
IR142doc 30143Max Import Power Demand Ch3FLOAT32ABCDRead
IR144doc 30145Max Import Power Demand Ch4FLOAT32ABCDRead
IR146doc 30147Max Export Power Demand Ch1FLOAT32ABCDRead
IR148doc 30149Max Export Power Demand Ch2FLOAT32ABCDRead
IR150doc 30151Max Export Power Demand Ch3FLOAT32ABCDRead
IR152doc 30153Max Export Power Demand Ch4FLOAT32ABCDRead
IR154doc 30155Max Import Current Demand Ch1FLOAT32ABCDRead
IR156doc 30157Max Import Current Demand Ch2FLOAT32ABCDRead
IR158doc 30159Max Import Current Demand Ch3FLOAT32ABCDRead
IR160doc 30161Max Import Current Demand Ch4FLOAT32ABCDRead
IR162doc 30163Max Export Current Demand Ch1FLOAT32ABCDRead
IR164doc 30165Max Export Current Demand Ch2FLOAT32ABCDRead
IR166doc 30167Max Export Current Demand Ch3FLOAT32ABCDRead
IR168doc 30169Max Export Current Demand Ch4FLOAT32ABCDRead
IR170doc 30171Energy Imp Ch1 on update rateFLOAT32ABCDRead
IR172doc 30173Energy Imp Ch2 on update rateFLOAT32ABCDRead
IR174doc 30175Energy Imp Ch3 on update rateFLOAT32ABCDRead
IR176doc 30177Energy Imp Ch4 on update rateFLOAT32ABCDRead
IR178doc 30179Energy Import Ch1 on update rate OFFLOAT32ABCDRead
IR180doc 30181Energy Import Ch2 on update rate OFFLOAT32ABCDRead
IR182doc 30183Energy Import Ch3 on update rate OFFLOAT32ABCDRead
IR184doc 30185Energy Import Ch4 on update rate OFFLOAT32ABCDRead
IR186doc 30187Energy Exp Ch1 on update rateFLOAT32ABCDRead
IR188doc 30189Energy Exp Ch2 on update rateFLOAT32ABCDRead
IR190doc 30191Energy Exp Ch3 on update rateFLOAT32ABCDRead
IR192doc 30193Energy Exp Ch4 on update rateFLOAT32ABCDRead
IR194doc 30195Energy Export Ch1 on update rate OFFLOAT32ABCDRead
IR196doc 30197Energy Export Ch2 on update rate OFFLOAT32ABCDRead
IR198doc 30199Energy Export Ch3 on update rate OFFLOAT32ABCDRead
IR200doc 30201Energy Export Ch4 on update rate OFFLOAT32ABCDRead
IR202doc 30203On HourFLOAT32ABCDRead
IR204doc 30205Run Hour Ch1FLOAT32ABCDRead
IR206doc 30207Run Hour Ch2FLOAT32ABCDRead
IR208doc 30209Run Hour Ch3FLOAT32ABCDRead
IR210doc 30211Run Hour Ch4FLOAT32ABCDRead
IR212doc 30213No. of InterruptionsFLOAT32ABCDRead
IR214doc 30215Old Energy Imp Ch 1FLOAT32ABCDRead
IR216doc 30217Old Energy Imp Ch 2FLOAT32ABCDRead
IR218doc 30219Old Energy Imp Ch 3FLOAT32ABCDRead
IR220doc 30221Old Energy Imp Ch 4FLOAT32ABCDRead
IR222doc 30223Old Energy Import Ch1 OFFLOAT32ABCDRead
IR224doc 30225Old Energy Import Ch2 OFFLOAT32ABCDRead
IR226doc 30227Old Energy Import Ch3 OFFLOAT32ABCDRead
IR228doc 30229Old Energy Import Ch4 OFFLOAT32ABCDRead
IR230doc 30231Old Energy Exp Ch 1FLOAT32ABCDRead
IR232doc 30233Old Energy Exp Ch 2FLOAT32ABCDRead
IR234doc 30235Old Energy Exp Ch 3FLOAT32ABCDRead
IR236doc 30237Old Energy Exp Ch 4FLOAT32ABCDRead
IR238doc 30239Old Energy Export Ch1 OFFLOAT32ABCDRead
IR240doc 30241Old Energy Export Ch2 OFFLOAT32ABCDRead
IR242doc 30243Old Energy Export Ch3 OFFLOAT32ABCDRead
IR244doc 30245Old Energy Export Ch4 OFFLOAT32ABCDRead
IR246doc 30247Old Amp Hour Imp Ch1FLOAT32ABCDRead
IR248doc 30249Old Amp Hour Imp Ch2FLOAT32ABCDRead
IR250doc 30251Old Amp Hour Imp Ch3FLOAT32ABCDRead
IR252doc 30253Old Amp Hour Imp Ch4FLOAT32ABCDRead
IR254doc 30255Old Amp Hour Exp Ch1FLOAT32ABCDRead
IR256doc 30257Old Amp Hour Exp Ch2FLOAT32ABCDRead
IR258doc 30259Old Amp Hour Exp Ch3FLOAT32ABCDRead
IR260doc 30261Old Amp Hour Exp Ch4FLOAT32ABCDRead
IR262doc 30263Old Max Import Power Demand Ch1FLOAT32ABCDRead
IR264doc 30265Old Max Import Power Demand Ch2FLOAT32ABCDRead
IR266doc 30267Old Max Import Power Demand Ch3FLOAT32ABCDRead
IR268doc 30269Old Max Import Power Demand Ch4FLOAT32ABCDRead
IR270doc 30271Old Max Export Power Demand Ch1FLOAT32ABCDRead
IR272doc 30273Old Max Export Power Demand Ch2FLOAT32ABCDRead
IR274doc 30275Old Max Export Power Demand Ch3FLOAT32ABCDRead
IR276doc 30277Old Max Export Power Demand Ch4FLOAT32ABCDRead
IR278doc 30279Old Max Import Current Demand Ch1FLOAT32ABCDRead
IR280doc 30281Old Max Import Current Demand Ch2FLOAT32ABCDRead
IR282doc 30283Old Max Import Current Demand Ch3FLOAT32ABCDRead
IR284doc 30285Old Max Import Current Demand Ch4FLOAT32ABCDRead
IR286doc 30287Old Max Export Current Demand Ch1FLOAT32ABCDRead
IR288doc 30289Old Max Export Current Demand Ch2FLOAT32ABCDRead
IR290doc 30291Old Max Export Current Demand Ch3FLOAT32ABCDRead
IR292doc 30293Old Max Export Current Demand Ch4FLOAT32ABCDRead
IR294doc 30295Old On HourFLOAT32ABCDRead
IR296doc 30297Old Run Hour Ch1FLOAT32ABCDRead
IR298doc 30299Old Run Hour Ch2FLOAT32ABCDRead
IR300doc 30301Old Run Hour Ch3FLOAT32ABCDRead
IR302doc 30303Old Run Hour Ch4FLOAT32ABCDRead
IR304doc 30305Old No. of InterruptionsFLOAT32ABCDRead
IR306doc 30307Energy Import Ch1 OFFLOAT32ABCDRead
IR308doc 30309Energy Import Ch2 OFFLOAT32ABCDRead
IR310doc 30311Energy Import Ch3 OFFLOAT32ABCDRead
IR312doc 30313Energy Import Ch4 OFFLOAT32ABCDRead
IR314doc 30315Energy Export Ch1 OFFLOAT32ABCDRead
IR316doc 30317Energy Export Ch2 OFFLOAT32ABCDRead
IR318doc 30319Energy Export Ch3 OFFLOAT32ABCDRead
IR320doc 30321Energy Export Ch4 OFFLOAT32ABCDRead
IR322doc 30323Total Import Energy OFFLOAT32ABCDRead
IR324doc 30325Total Export Energy OFFLOAT32ABCDRead
IR326doc 30327AH Import Ch1 OFFLOAT32ABCDRead
IR328doc 30329AH Import Ch2 OFFLOAT32ABCDRead
IR330doc 30331AH Import Ch3 OFFLOAT32ABCDRead
IR332doc 30333AH Import Ch4 OFFLOAT32ABCDRead
IR334doc 30335AH Export Ch1 OFFLOAT32ABCDRead
IR336doc 30337AH Export Ch2 OFFLOAT32ABCDRead
IR338doc 30339AH Export Ch3 OFFLOAT32ABCDRead
IR340doc 30341AH Export Ch4 OFFLOAT32ABCDRead
IR342doc 30343Total Import AH OFFLOAT32ABCDRead
IR344doc 30345Total Export AH OFFLOAT32ABCDRead
IR346doc 30347Old AH Import Ch1 OFFLOAT32ABCDRead
IR348doc 30349Old AH Import Ch2 OFFLOAT32ABCDRead
IR350doc 30351Old AH Import Ch3 OFFLOAT32ABCDRead
IR352doc 30353Old AH Import Ch4 OFFLOAT32ABCDRead
IR354doc 30355Old AH Export Ch1 OFFLOAT32ABCDRead
IR356doc 30357Old AH Export Ch2 OFFLOAT32ABCDRead
IR358doc 30359Old AH Export Ch3 OFFLOAT32ABCDRead
IR360doc 30361Old AH Export Ch4 OFFLOAT32ABCDRead
IR362doc 30363Relay 1 StatusFLOAT32ABCDRead
IR364doc 30365Relay 2 StatusFLOAT32ABCDRead
IR366doc 30367Relay 3 StatusFLOAT32ABCDRead
IR368doc 30369Relay 4 StatusFLOAT32ABCDRead
IR370doc 30371Timer 1 On DelayFLOAT32ABCDRead
IR372doc 30373Timer 2 On DelayFLOAT32ABCDRead
IR374doc 30375Timer 3 On DelayFLOAT32ABCDRead
IR376doc 30377Timer 4 On DelayFLOAT32ABCDRead
IR378doc 30379Timer 1 Off DelayFLOAT32ABCDRead
IR380doc 30381Timer 2 Off DelayFLOAT32ABCDRead
IR382doc 30383Timer 3 Off DelayFLOAT32ABCDRead
IR384doc 30385Timer 4 Off DelayFLOAT32ABCDRead
IR386doc 30387Timer 1 No of CyclesFLOAT32ABCDRead
IR388doc 30389Timer 2 No of CyclesFLOAT32ABCDRead
IR390doc 30391Timer 3 No of CyclesFLOAT32ABCDRead
IR392doc 30393Timer 4 No of CyclesFLOAT32ABCDRead
IR394doc 30395RTC MinFLOAT32ABCDRead
IR396doc 30397RTC HourFLOAT32ABCDRead
IR398doc 30399RTC Day of WeekFLOAT32ABCDRead
IR400doc 30401RTC DateFLOAT32ABCDRead
IR402doc 30403RTC MonthFLOAT32ABCDRead
IR404doc 30405RTC YearFLOAT32ABCDRead
IR406doc 30407RTC Complete Date*FLOAT32ABCDRead
IR408doc 30409RTC Complete Time*FLOAT32ABCDRead
HR2doc 40003Demand Integration TimeSetup parameter (float).FLOAT32ABCDRead/write
HR4doc 40005Reset parametersSetup parameter (float).FLOAT32ABCDRead/write
HR6doc 40007RS485 Setup CodeSetup parameter (float).FLOAT32ABCDRead/write
HR8doc 40009Mod addressSetup parameter (float).FLOAT32ABCDRead/write
HR26doc 40027Nominal VoltageSetup parameter (float).FLOAT32ABCDRead/write
HR28doc 40029Auto Detect Nominal VoltageSetup parameter (float).FLOAT32ABCDRead/write
HR30doc 40031Channel SelectSetup parameter (float).FLOAT32ABCDRead/write
HR32doc 40033Current - Full Scale Ch1Setup parameter (float).FLOAT32ABCDRead/write
HR34doc 40035Current - Full Scale Ch2Setup parameter (float).FLOAT32ABCDRead/write
HR36doc 40037Current - Full Scale Ch3Setup parameter (float).FLOAT32ABCDRead/write
HR38doc 40039Current - Full Scale Ch4Setup parameter (float).FLOAT32ABCDRead/write
HR40doc 40041Current - Shunt Ch1Setup parameter (float).FLOAT32ABCDRead/write
HR42doc 40043Current - Shunt Ch2Setup parameter (float).FLOAT32ABCDRead/write
HR44doc 40045Current - Shunt Ch3Setup parameter (float).FLOAT32ABCDRead/write
HR46doc 40047Current - Shunt Ch4Setup parameter (float).FLOAT32ABCDRead/write
HR60doc 40061Energy Output Ch1Setup parameter (float).FLOAT32ABCDRead/write
HR62doc 40063Energy Output Ch2Setup parameter (float).FLOAT32ABCDRead/write
HR64doc 40065Energy Output Ch3Setup parameter (float).FLOAT32ABCDRead/write
HR66doc 40067Energy Output Ch4Setup parameter (float).FLOAT32ABCDRead/write
HR72doc 40073Register orderSetup parameter (float).FLOAT32ABCDRead/write
HR74doc 40075Auto ScrollSetup parameter (float).FLOAT32ABCDRead/write
HR94doc 40095PasswordSetup parameter (float).FLOAT32ABCDRead/write
HR96doc 40097Serial NumberRead-only identification value (float).FLOAT32ABCDRead
HR98doc 40099Model NumberSetup parameter (float).FLOAT32ABCDRead/write
HR100doc 40101Firmware Version NumberRead-only identification value (float).FLOAT32ABCDRead
HR360doc 40361Password for Energy Starting CountSetup parameter (float).FLOAT32ABCDRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter

What Modbus registers does the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter have?

This map lists 223 registers: 197 input registers, 26 holding registers. 24 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The manual prints 30001/40001-style addresses next to the hex start address actually sent (30001 = 0x0000). Wire address = printed number - 30001 (input registers) or - 40001 (holding registers); every value here was cross-checked against the printed hex address.

What byte order does the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter?

Start with IR 0 Voltage (DC voltage); IR 2 Current Ch1 (Channel 1 current); IR 10 Power Ch1 (Channel 1 power); IR 18 Total Import Power (Total import power); IR 38 Total Import Energy (Total import energy); IR 40 Total Export Energy (Total export energy).

How do I enable Modbus control of the Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter?

Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.

Where is the official Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter Modbus documentation?

The source is RISH EM DC Interface Definition (2-60-006-00-00627 Rev. 0), revision 2015-10, published free by Rishabh Instruments at https://rishabh.co.in/uploads/product/multi-channel-dc-energy-meter-rish-em-dc-6001-6002-146/RISH_EM_DC__Interface_definition.pdf.

More Rishabh Instruments Modbus register maps

Other power & energy meters register maps

All power & energy meters Modbus register maps →

Source: RISH EM DC Interface Definition · 2-60-006-00-00627 Rev. 0 · rev. 2015-10. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.