Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters Modbus register map
Updated 19 November 2026
Single-phase energy meters from Rishabh's 21XX line in direct-connected (ED), CT-connected (EC) and RJ12 CT (ER) versions; the Modbus variants have an RS-485 port speaking Modbus RTU (M-Bus variants exist too). Every measured value is an IEEE 754 float in two registers, readable as input registers from 30001 or as holding registers at the same offset from 40001. This map covers voltage, current, power, PF, frequency, demands, total/tariff/partial energies and the main setup registers.
This page lists 85 Modbus registers for the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters — 5 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Rishabh Instruments’s own free documentation (linked below) and checked against it.
- Manufacturer
- Rishabh Instruments
- Model
- RISH ED21XX / EC21XX / ER21XX single-phase energy meters
- Equipment type
- Energy meter
- Registers
- 85 (5 writable)
- Transport
- Modbus RTU
- Default unit ID
- 1
- Default serial
- 9600 baud, 8N1
- Documented addressing
- Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
- 32-bit word order
- ABCD high word first (big-endian)
- Also known as
- RISH ED21X1, RISH EC21X1, RISH ER21X1, RISH ED21XX, RISH EC21XX, RISH ER21XX
Integration notes: Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters
Read 30001-30038 for instantaneous values and 30107-30142 for energies with FC04 (or FC03 at 40001+) and decode each register pair as a big-endian float.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| IR 0 | Voltage | FLOAT32 ABCD | Voltage | Read |
| IR 6 | Current | FLOAT32 ABCD | Current | Read |
| IR 12 | Active Power | FLOAT32 ABCD | Active power | Read |
| IR 30 | Power Factor | FLOAT32 ABCD | Power factor | Read |
| IR 70 | Frequency | FLOAT32 ABCD | Frequency | Read |
| IR 108 | Active Import Energy | FLOAT32 ABCD | Active import energy (kWh) | Read |
Enable Modbus control & writes
Only the Modbus variants have RS-485 (M-Bus variants use a different protocol). Set address and baud/parity from the front-panel setup (address 001 and 9600 baud, no parity by default; check stop bits, see notes) or via 46025/46027.
Byte order & addressing
- Setup values are floats too: total energy formula 1 reads back as 3F 80 00 00.
- Reading or writing half a float returns exception 02.
Network setup
- Comsetup (46027) codes 0-19 pack baud 2400-38400, parity and stop bits.
Watch out for
- Changing CT settings on EC/ER models locks after a countdown (46021); plan CT changes during commissioning.
Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| IR | 0doc 30001 | Voltage | FLOAT32 | ABCD | V | Read | |||
| IR | 6doc 30007 | Current | FLOAT32 | ABCD | A | Read | |||
| IR | 12doc 30013 | Active Power | FLOAT32 | ABCD | W | Read | |||
| IR | 18doc 30019 | Apparent Power | FLOAT32 | ABCD | VA | Read | |||
| IR | 24doc 30025 | Reactive Power | FLOAT32 | ABCD | VAr | Read | |||
| IR | 30doc 30031 | Power Factor | FLOAT32 | ABCD | Read | ||||
| IR | 70doc 30071 | Frequency | FLOAT32 | ABCD | Hz | Read | |||
| IR | 72doc 30073 | W Import Demand | FLOAT32 | ABCD | W | Read | |||
| IR | 74doc 30075 | W Import Max Demand | FLOAT32 | ABCD | W | Read | |||
| IR | 76doc 30077 | W Export Demand | FLOAT32 | ABCD | W | Read | |||
| IR | 78doc 30079 | W Exp. Max Demand | FLOAT32 | ABCD | W | Read | |||
| IR | 80doc 30081 | var Imp. / Ind Demand | FLOAT32 | ABCD | VAr | Read | |||
| IR | 82doc 30083 | var Imp./ Ind Max Demand | FLOAT32 | ABCD | VAr | Read | |||
| IR | 86doc 30087 | var Exp. / Cap Max Demand | FLOAT32 | ABCD | VAr | Read | |||
| IR | 88doc 30089 | va Imp. Demand | FLOAT32 | ABCD | VA | Read | |||
| IR | 90doc 30091 | va Imp. Max Demand | FLOAT32 | ABCD | VA | Read | |||
| IR | 92doc 30093 | va Exp. Demand | FLOAT32 | ABCD | VA | Read | |||
| IR | 94doc 30095 | va Exp. Max Demand | FLOAT32 | ABCD | VA | Read | |||
| IR | 96doc 30097 | Current Imp. Demand | FLOAT32 | ABCD | A | Read | |||
| IR | 98doc 30099 | Current Imp Max. Demand | FLOAT32 | ABCD | A | Read | |||
| IR | 106doc 30107 | Active Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 108doc 30109 | Active Import Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 110doc 30111 | Active Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 112doc 30113 | Active Export Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 114doc 30115 | Reactive Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 116doc 30117 | Reactive Import Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 118doc 30119 | Reactive Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 120doc 30121 | Reactive Export Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 130doc 30131 | Total Active Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 132doc 30133 | Total Active Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 134doc 30135 | Total Reactive Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 136doc 30137 | Total Reactive Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 138doc 30139 | Total Apparent Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 140doc 30141 | Total Apparent Energy | FLOAT32 | ABCD | kVAh | Read | |||
| IR | 142doc 30143 | T1 Active Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 144doc 30145 | T1 Active Import Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 146doc 30147 | T1 Active Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 148doc 30149 | T1 Active Export Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 150doc 30151 | T1 Reactive Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 152doc 30153 | T1 Reactive Import Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 154doc 30155 | T1 Reactive Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 156doc 30157 | T1 Reactive Export Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 166doc 30167 | T1 Total Active Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 168doc 30169 | T1 Total Active Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 170doc 30171 | T1 Total Reactive Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 172doc 30173 | T1 Total Reactive Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 174doc 30175 | T1 Total Apparent Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 176doc 30177 | T1 Total Apparent Energy | FLOAT32 | ABCD | kVAh | Read | |||
| IR | 178doc 30179 | T2 Active Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 180doc 30181 | T2 Active Import Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 182doc 30183 | T2 Active Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 184doc 30185 | T2 Active Export Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 186doc 30187 | T2 Reactive Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 188doc 30189 | T2 Reactive Import Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 190doc 30191 | T2 Reactive Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 192doc 30193 | T2 Reactive Export Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 202doc 30203 | T2 Total Active Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 204doc 30205 | T2 Total Active Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 206doc 30207 | T2 Total Reactive Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 208doc 30209 | T2 Total Reactive Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 210doc 30211 | T2 Total Apparent Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 212doc 30213 | T2 Total Apparent Energy | FLOAT32 | ABCD | kVAh | Read | |||
| IR | 214doc 30215 | Partial Active Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 216doc 30217 | Partial Active Import Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 218doc 30219 | Partial Active Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 220doc 30221 | Partial Active Export Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 222doc 30223 | Partial Reactive Import Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 224doc 30225 | Partial Reactive Import Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 226doc 30227 | Partial Reactive Export Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 228doc 30229 | Partial Reactive Export Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 238doc 30239 | Partial Total Active Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 240doc 30241 | Partial Total Active Energy | FLOAT32 | ABCD | kWh | Read | |||
| IR | 242doc 30243 | Partial TotalReactive Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 244doc 30245 | Partial Total Reactive Energy | FLOAT32 | ABCD | kVArh | Read | |||
| IR | 246doc 30247 | Partial Total Apparent Energy Overflow Count | Roll-overs of the matching energy register. | FLOAT32 | ABCD | Read | |||
| IR | 248doc 30249 | Partial Total Apparent Energy | FLOAT32 | ABCD | kVAh | Read | |||
| IR | 254doc 30255 | No of Interrupts | FLOAT32 | ABCD | Read | ||||
| IR | 256doc 30257 | Impulse Rate | FLOAT32 | ABCD | Read | ||||
| IR | 260doc 30261 | Tariff Status | FLOAT32 | ABCD | Read | ||||
| IR | 262doc 30263 | Current Direction | FLOAT32 | ABCD | Read | 0 = Current in the marked direction; 1 = Current reversed | |||
| HR | 6002doc 46003 | Demand integration time | Demand period in minutes. | FLOAT32 | ABCD | Read/write | 5 = 5 min; 10 = 10 min; 15 = 15 min; 30 = 30 min | ||
| HR | 6006doc 46007 | Total energy counter formula | FLOAT32 | ABCD | Read/write | 1 = Import only; 2 = Export only; 3 = Import + export | |||
| HR | 6008doc 46009 | Import/export reactive energy formula | FLOAT32 | ABCD | Read/write | 1 = Import/export (Q1+Q2 / Q3+Q4); 2 = Inductive/capacitive (Q1+Q3 / Q2+Q4) | |||
| HR | 6024doc 46025 | Modbus address | 1-247. | FLOAT32 | ABCD | Read/write | |||
| HR | 6026doc 46027 | Comsetup | Baud, parity and stop bits in one code. | FLOAT32 | ABCD | Read/write | 0 = 2400 bps, no parity, 1 stop; 1 = 2400 bps, no parity, 2 stop; 2 = 2400 bps, even, 1 stop; 3 = 2400 bps, odd, 1 stop; 4 = 4800 bps, no parity, 1 stop; 5 = 4800 bps, no parity, 2 stop; 6 = 4800 bps, even, 1 stop; 7 = 4800 bps, odd, 1 stop; 8 = 9600 bps, no parity, 1 stop; 9 = 9600 bps, no parity, 2 stop; 10 = 9600 bps, even, 1 stop; 11 = 9600 bps, odd, 1 stop; 12 = 19200 bps, no parity, 1 stop; 13 = 19200 bps, no parity, 2 stop; 14 = 19200 bps, even, 1 stop; 15 = 19200 bps, odd, 1 stop; 16 = 38400 bps, no parity, 1 stop; 17 = 38400 bps, no parity, 2 stop; 18 = 38400 bps, even, 1 stop; 19 = 38400 bps, odd, 1 stop |
Notes on this map
- The data-format table states IEEE 754 floats, most significant byte first. The voltage read example returns 43 66 00 00 (230 V), most significant word first, so word order is ABCD.
- Every 3X value is also a 4X holding register at the same offset (30001 -> 40001); only the 3X copies are listed.
- Left out: parameter 42 (printed with the same name as 43), the 'long energy' Table 5 (30513-30655, format not described) and the user-assignable registers (31025-31051).
- Units are as printed (Volts -> V, Amp -> A, Watt -> W). Energy overflow counts increase each time the matching energy passes 99999.999.
- Up to 40 parameters per read request.
- Table 4 prints 'Total Apparent Energy' (and its overflow count) twice in each block: at 30123/30125 and again at 30139/30141 (same for T1 30159/30161 vs 30175/30177, T2 30195/30197 vs 30211/30213, partial 30231/30233 vs 30247/30249). The first copy of each pair is left out because its real meaning is unclear; the second copy sits where the long-energy Table 5 puts total apparent energy.
- Default stop bits are not settled: the front-panel section gives nonE1 (no parity, 1 stop) but Table 6 prints Comsetup default 9 (9600, no parity, 2 stop). Both agree on 9600 baud and no parity. Some setup rows also differ between ED and EC/ER models; only the clearly described rows are listed.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters
What Modbus registers does the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters have?
This map lists 85 registers: 80 input registers, 5 holding registers. 5 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Table 4 prints 3X and 4X numbers next to the hex start address (30001 = 00 00, 30071 = 00 46). Wire address = number - 30001 (FC04) or - 40001 (FC03); every row was checked against the printed hex and parameter number. The setup example reads 46007 at 17 76.
What byte order does the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters use for 32-bit values?
Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.
What are the minimum Modbus registers to integrate the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters?
Start with IR 0 Voltage (Voltage); IR 6 Current (Current); IR 12 Active Power (Active power); IR 30 Power Factor (Power factor); IR 70 Frequency (Frequency); IR 108 Active Import Energy (Active import energy (kWh)).
How do I enable Modbus control of the Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters?
Only the Modbus variants have RS-485 (M-Bus variants use a different protocol). Set address and baud/parity from the front-panel setup (address 001 and 9600 baud, no parity by default; check stop bits, see notes) or via 46025/46027.
Where is the official Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters Modbus documentation?
The source is Operating Manual RISH ED21XX / EC21XX / ER21XX Single Phase AC Energy Meters (DMAN-00IM-1073 Rev. M), revision 09/26, published free by Rishabh Instruments at https://rishabh.co.in/uploads/product/rish-ec21xx-258/RISH%20ED_EC_ER_21XX_Operating_Manual_REV_M.pdf.
More Rishabh Instruments Modbus register maps
- Energy meter (DC)
Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter
Rishabh RISH DC2111 MOD single-channel DC energy meters with RS-485 Modbus, per interface definition DMAN-00IM-1669 Rev. D (08/25).
Also known as: RISH DC2111 MOD, DC2111 - Energy meter
Rishabh Instruments RISH Delta Energy NX multifunction energy meter
Rishabh RISH Delta Energy NX panel energy meters with RS-485 Modbus RTU, per the operating manual on the product page (standard CT version).
Also known as: RISH Delta Energy NX, Delta Energy NX, RISH Delta Energy - Power meter
Rishabh Instruments RISH Delta Power NX multifunction power meter
Rishabh RISH Delta Power NX programmable panel meters with RS-485 Modbus RTU, per operating manual AMAN-00IM-0117 Rev. E.
Also known as: RISH Delta Power NX, Delta Power NX, RISH Delta Power - Power meter
Rishabh Instruments RISH Delta VAF NX volt/amp/frequency panel meter
Rishabh RISH Delta VAF NX programmable panel meters with RS-485 Modbus RTU, per operating manual AMAN-00IM-0118 Rev. F.
Also known as: RISH Delta VAF NX, Delta VAF NX, RISH Delta VAF - Power meter (demand controller)
Rishabh Instruments RISH DMCi touch-screen demand controller with TOD
Rishabh RISH DMCi 96 x 96 mm touch-screen demand controllers with the optional RS-485 Modbus output, per interface definition DMAN-00IM-0578 Rev. A (09/16).
Also known as: RISH DMCi, DMCi, Rish DMCi demand controller - Energy meter
Rishabh Instruments RISH EC43xx / ER43xx DIN-rail energy meters
Rishabh RISH EC43xx and ER43xx DIN-rail digital energy meters with RS-485 Modbus, per interface definition DMAN-00IM-09xx Rev. F (11/25).
Also known as: EC4311, EC4321, ER4311, ER4321, RISH EC43X1, EC43XX, ER43XX - Energy meter
Rishabh Instruments RISH ED11XX / EC11XX / ER11XX single-phase DIN-rail energy meters
Rishabh RISH ED11XX (direct), EC11XX (CT) and ER11XX (RJ12 CT) single-phase DIN-rail meters in their Modbus (x1) versions, per operating manual DMAN-00IM-1071 Rev. M.
Also known as: RISH ED11X1, RISH EC11X1, RISH ER11X1, ED1111, EC1111, ER1111, RISH ED11XX, RISH EC11XX, RISH ER11XX - Energy meter
Rishabh Instruments RISH EM 1320 / 1330 / 1340 / 2340 programmable energy meters
Rishabh RISH EM 1320/1330/1340 and EM 2320/2330/2340 panel energy meters with RS-485 Modbus, per interface definition DMAN-00IM-0721 Rev. B (06/2020). Rows marked 'only 2340' apply to the dual-source EM 2340.
Also known as: RISH EM 1320, RISH EM 1330, RISH EM 1340, RISH EM 2320, RISH EM 2330, RISH EM 2340, EM2340DS - Energy meter
Rishabh Instruments RISH EM 3490 DS dual-source (utility/generator) energy meter
Rishabh RISH EM 3490 DS dual-source energy meters (separate utility and generator energy) with RS-485 Modbus, per manual Rev G.
Also known as: RISH EM 3490 DS, EM3490DS, EM 3490DS - Energy meter
Rishabh Instruments RISH EM 3490 SS single-phase energy meter
Rishabh RISH EM 3490 SS single-phase energy meters with the optional RS-485 Modbus output, per the 1-phase manual Rev D.
Also known as: RISH EM 3490 SS 1P, EM3490SS 1P, EM 3490 SS single-phase - Energy meter
Rishabh Instruments RISH EM 3490 SS three-phase single-source energy meter
Rishabh RISH EM 3490 SS three-phase energy meters with the optional RS-485 Modbus output, per the 3-phase manual Rev E.
Also known as: RISH EM 3490 SS 3P, EM3490SS 3P, EM 3490 SS three-phase - Energy meter (DC)
Rishabh Instruments RISH EM DC 6000 programmable DC energy meter
Rishabh RISH EM DC 6000 single-channel programmable DC energy meters with RS-485 Modbus, per interface definition DMAN-00IM-0862 Rev. 0 (12/2020).
Also known as: RISH EM DC 6000, EMDC 6000, EM DC6000 - Energy meter (DC)
Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter
Rishabh RISH EM DC 6001 / 6002 multi-channel DC energy meters with RS-485 Modbus, per interface definition 2-60-006-00-00627 Rev. 0 (10/2015).
Also known as: RISH EM DC 6001, RISH EM DC 6002, EM DC 6001, EM DC 6002 - Power meter
Rishabh Instruments RISH LM 1340 multifunction meter
Rishabh RISH LM 1340 panel multifunction instruments with RS-485 Modbus, per interface definition DMAN-00IM-0923 Rev. D (03/2026).
Also known as: RISH LM 1340, LM1340 - Power meter
Rishabh Instruments RISH LM 1360 load manager (LM 13xx)
Rishabh RISH LM 1360 panel meters with RS-485 Modbus, per interface definition DMAN-00IM-0662 Rev. D (01/2024).
Also known as: RISH LM 1360, LM1360, LM 13xx, LM1360 RJ12 - Power meter
Rishabh Instruments RISH LM 1380 multifunction meter
Rishabh RISH LM 1380 panel multifunction instruments with RS-485 Modbus, per interface definition DMAN-00IM-0925 Rev. A (04/2022).
Also known as: RISH LM 1380, LM1380 - Power meter
Rishabh Instruments RISH LM1360+ RJ12 smart energy meter
Rishabh RISH LM1360 PLUS RJ12 smart energy meters (RJ12 CT inputs) with RS-485 Modbus, per interface definition DMAN-00IM-0923 Rev. A (01/2026).
Also known as: RISH LM 1360+, LM1360 PLUS RJ12, LM1360+ - Power meter
Rishabh Instruments RISH Master 3440 (class 0.2S) multifunction meter
Rishabh RISH Master 3440 class 0.2S panel meters with RS-485 Modbus, per interface definition DMAN-00IM-0711 Rev. C (05/2019).
Also known as: RISH Master 3440, RM3440, Master 3440 0.2S - Power meter
Rishabh Instruments RISH Master 3440i / 3440iDL (class 0.2S) touch-screen meter
Rishabh RISH Master 3440i and 3440iDL touch-screen class 0.2S meters with RS-485 Modbus, per interface definition DMAN-00IM-0712 Rev. F (10/2026).
Also known as: RISH Master 3440i, RISH Master 3440iDL, RM3440i, RM3440iDL - Power meter (multi-circuit energy meter)
Rishabh Instruments RISH ML 1400 / ML 1410 Multiload Monitor (Modbus RTU)
RISH Multiload Monitor (12 current channels, 4 voltage channels) per interface definition DMAN-00IM-0795 Rev A (08/2020).
Also known as: RISH ML 1400, RISH ML 1410, RISH MLM, Multiload Monitor - Power meter (power factor controller)
Rishabh Instruments RISH PFC 96 / PFC 144 automatic power factor controller
Rishabh RISH PFC 96 and PFC 144 automatic power factor (APFC) controllers with RS-485 Modbus RTU, per interface definition version D (12/18).
Also known as: RISH PFC 96, RISH PFC 144, PFC96, PFC144, RISH PFC-12, APFC
Other power & energy meters register maps
- Power meter (power quality analyzer)
SATEC PM175 powermeter and power quality analyzer
SATEC PM175 from firmware 25.2.6, per Modbus reference guide BG0416 Rev. A7 (Nov 2009).
Also known as: PM175, SATEC PM175, PM 175 - Energy meter
Senva EM-RS485 networked energy meter (Modbus RTU/ASCII)
Senva EM-RS485 three-phase energy meters with Senva CVT sensors, firmware v1.1.2, Modbus Protocol Guide 154-0023-0B (2017-04-10).
Also known as: EM-RS485, Senva EM-RS485, Senva protocol energy meter - Sensor (geotechnical: inclinometer, tiltmeter, piezometer, extensometer)
SISGEO SISGEO digital instruments, RS-485 Modbus (firmware 3.x normal mode)
SISGEO digital instruments with firmware 0x0300 or later running in normal (non-legacy) mode, protocol manual EN 05/20.
Also known as: SISGEO digital in-place inclinometer, SISGEO digital tiltmeter, SISGEO digital piezometer, SISGEO DEX, SISGEO digital extensometer - Energy meter
ABB EQ meter A41 / A42 (Modbus RTU)
ABB EQ A41 (direct connected) and A42 (transformer connected) DIN meters whose RS-485 port is set to Modbus.
Also known as: A41, A42, EQ A41, EQ A42 - Power meter (circuit breaker trip unit)
ABB SACE Tmax PR223DS trip unit (Modbus RTU)
ABB SACE PR223DS electronic trip unit (Tmax moulded-case breakers), software version 02.02, per 1SDH000658R0001.
Also known as: PR223DS, Tmax PR223DS, SACE PR223DS - Power meter
BTicino PM multifunction meter F3N200 (Modbus RTU)
BTicino PM multifunction meter catalogue number F3N200 with RS-485, per Modbus table IDP000024 v1.01.
Also known as: F3N200, BTicino PM F3N200
All power & energy meters Modbus register maps →
Source: Operating Manual RISH ED21XX / EC21XX / ER21XX Single Phase AC Energy Meters · DMAN-00IM-1073 Rev. M · rev. 09/26. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.