- Home
- Modbus register maps
- Rishabh Instruments
- RISH LM 1380 multifunction meter
Power meter · Modbus register map
Rishabh Instruments RISH LM 1380 multifunction meter Modbus register map
Updated 17 November 2026
The RISH LM 1380 multifunction meter is a 96 x 96 mm panel multifunction meter that measures voltage, current, power, power factor, frequency, harmonics and energy on 3-phase 4-wire, 3-phase 3-wire or single-phase networks. Its RS-485 port speaks Modbus RTU and every reading is a 32-bit IEEE float in two registers. This map covers the regular per-phase and system parameters (Table 1.1) and the float energy registers (Table 1.3), plus the main setup registers (system type, CT/PT ratios, demand period, communication and word-order settings).
This page lists 277 Modbus registers for the Rishabh Instruments RISH LM 1380 multifunction meter — 12 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Rishabh Instruments’s own free documentation (linked below) and checked against it.
- Manufacturer
- Rishabh Instruments
- Model
- RISH LM 1380 multifunction meter
- Equipment type
- Power meter
- Registers
- 277 (12 writable)
- Transport
- Modbus RTU
- Default unit ID
- 1
- Documented addressing
- Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
- 32-bit word order
- ABCD high word first (big-endian)
- Also known as
- RISH LM 1380, LM1380
Integration notes: Rishabh Instruments RISH LM 1380 multifunction meter
Read measured values with FC04 (or FC03 at the 4X copies) in pairs of registers and decode them as ABCD floats. Settings are floats too and are written with FC16.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| IR 0 | Voltage L1 (Voltage L12 for 3P3W) | FLOAT32 ABCD | Voltage L1 | Read |
| IR 6 | Current L1 | FLOAT32 ABCD | Current L1 | Read |
| IR 52 | Watt Sum | FLOAT32 ABCD | Total active power (Watt Sum) | Read |
| IR 70 | Freq | FLOAT32 ABCD | Frequency | Read |
| IR 62 | PF Avg | FLOAT32 ABCD | Average power factor | Read |
| IR 1800 | Sys Active Energy Import | FLOAT32 ABCD | System active energy import | Read |
| IR 72 | Wh import | FLOAT32 ABCD | Active energy import (Wh import) | Read |
Enable Modbus control & writes
Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.
Byte order & addressing
- Each parameter is two registers; reading or writing only half of a float returns an Illegal Data Address exception.
- Addresses are Modicon-style: subtract 30001 or 40001 for the wire address.
- Limit each read to 40 parameters (80 registers) or less.
Network setup
- Slave address range 1-247; broadcast (address 0) is not supported.
- Allow about 300 ms for the meter to answer before retrying.
Watch out for
- If a password lock is set, write the valid password to the Password register before changing any 4X setting; a wrong password returns exception code 2.
Rishabh Instruments RISH LM 1380 multifunction meter Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| IR | 0doc 30001 | Voltage L1 (Voltage L12 for 3P3W) | FLOAT32 | ABCD | Read | ||||
| IR | 2doc 30003 | Voltage L2 (Voltage L23 for 3P3W) | FLOAT32 | ABCD | Read | ||||
| IR | 4doc 30005 | Voltage L3 (Voltage L31 for 3P3W) | FLOAT32 | ABCD | Read | ||||
| IR | 6doc 30007 | Current L1 | FLOAT32 | ABCD | Read | ||||
| IR | 8doc 30009 | Current L2 | FLOAT32 | ABCD | Read | ||||
| IR | 10doc 30011 | Current L3 | FLOAT32 | ABCD | Read | ||||
| IR | 12doc 30013 | Watt L1 | FLOAT32 | ABCD | Read | ||||
| IR | 14doc 30015 | Watt L2 | FLOAT32 | ABCD | Read | ||||
| IR | 16doc 30017 | Watt L3 | FLOAT32 | ABCD | Read | ||||
| IR | 18doc 30019 | VA L1 | FLOAT32 | ABCD | Read | ||||
| IR | 20doc 30021 | VA L2 | FLOAT32 | ABCD | Read | ||||
| IR | 22doc 30023 | VA L3 | FLOAT32 | ABCD | Read | ||||
| IR | 24doc 30025 | VAR L1 | FLOAT32 | ABCD | Read | ||||
| IR | 26doc 30027 | VAR L2 | FLOAT32 | ABCD | Read | ||||
| IR | 28doc 30029 | VAR L3 | FLOAT32 | ABCD | Read | ||||
| IR | 30doc 30031 | Power Factor L1 | FLOAT32 | ABCD | Read | ||||
| IR | 32doc 30033 | Power Factor L2 | FLOAT32 | ABCD | Read | ||||
| IR | 34doc 30035 | Power Factor L3 | FLOAT32 | ABCD | Read | ||||
| IR | 36doc 30037 | Phase Angle L1 | FLOAT32 | ABCD | Read | ||||
| IR | 38doc 30039 | Phase Angle L2 | FLOAT32 | ABCD | Read | ||||
| IR | 40doc 30041 | Phase Angle L3 | FLOAT32 | ABCD | Read | ||||
| IR | 42doc 30043 | Voltage Avg | FLOAT32 | ABCD | Read | ||||
| IR | 44doc 30045 | Voltage Sum | FLOAT32 | ABCD | Read | ||||
| IR | 46doc 30047 | Current Avg | FLOAT32 | ABCD | Read | ||||
| IR | 48doc 30049 | Current Sum | FLOAT32 | ABCD | Read | ||||
| IR | 50doc 30051 | Watt Avg | FLOAT32 | ABCD | Read | ||||
| IR | 52doc 30053 | Watt Sum | FLOAT32 | ABCD | Read | ||||
| IR | 54doc 30055 | VA Avg | FLOAT32 | ABCD | Read | ||||
| IR | 56doc 30057 | VA Sum | FLOAT32 | ABCD | Read | ||||
| IR | 58doc 30059 | VAR Avg | FLOAT32 | ABCD | Read | ||||
| IR | 60doc 30061 | VAr Sum | FLOAT32 | ABCD | Read | ||||
| IR | 62doc 30063 | PF Avg | FLOAT32 | ABCD | Read | ||||
| IR | 64doc 30065 | PF Sum | FLOAT32 | ABCD | Read | ||||
| IR | 66doc 30067 | Phase Angle Avg | FLOAT32 | ABCD | Read | ||||
| IR | 68doc 30069 | Phase Angle Sum | FLOAT32 | ABCD | Read | ||||
| IR | 70doc 30071 | Freq | FLOAT32 | ABCD | Read | ||||
| IR | 72doc 30073 | Wh import | FLOAT32 | ABCD | Read | ||||
| IR | 74doc 30075 | Wh export | FLOAT32 | ABCD | Read | ||||
| IR | 76doc 30077 | VArh Capacitive | FLOAT32 | ABCD | Read | ||||
| IR | 78doc 30079 | VArh Inductive | FLOAT32 | ABCD | Read | ||||
| IR | 80doc 30081 | VAh | FLOAT32 | ABCD | Read | ||||
| IR | 84doc 30085 | kW imp demand | FLOAT32 | ABCD | Read | ||||
| IR | 86doc 30087 | max kW imp demand | FLOAT32 | ABCD | Read | ||||
| IR | 88doc 30089 | kW exp demand | FLOAT32 | ABCD | Read | ||||
| IR | 90doc 30091 | max kW exp demand | FLOAT32 | ABCD | Read | ||||
| IR | 92doc 30093 | kVAr Cap. demand | FLOAT32 | ABCD | Read | ||||
| IR | 94doc 30095 | max kVAr Cap. demand | FLOAT32 | ABCD | Read | ||||
| IR | 96doc 30097 | kVAr Ind. demand | FLOAT32 | ABCD | Read | ||||
| IR | 98doc 30099 | max kVAr Ind. demand | FLOAT32 | ABCD | Read | ||||
| IR | 100doc 30101 | KVA demand | FLOAT32 | ABCD | Read | ||||
| IR | 102doc 30103 | max KVA demand | FLOAT32 | ABCD | Read | ||||
| IR | 104doc 30105 | current demand | FLOAT32 | ABCD | Read | ||||
| IR | 106doc 30107 | max current demand | FLOAT32 | ABCD | Read | ||||
| IR | 108doc 30109 | Wh import Overflow count | FLOAT32 | ABCD | Read | ||||
| IR | 110doc 30111 | Wh Import | FLOAT32 | ABCD | Read | ||||
| IR | 112doc 30113 | Wh export Overflow count | FLOAT32 | ABCD | Read | ||||
| IR | 114doc 30115 | Wh export | FLOAT32 | ABCD | Read | ||||
| IR | 116doc 30117 | VArh Cap. Overflow count | FLOAT32 | ABCD | Read | ||||
| IR | 118doc 30119 | VArh Capacitive | FLOAT32 | ABCD | Read | ||||
| IR | 120doc 30121 | VArh Ind. Overflow count | FLOAT32 | ABCD | Read | ||||
| IR | 122doc 30123 | VARh Inductive | FLOAT32 | ABCD | Read | ||||
| IR | 124doc 30125 | VAh Overflow count | FLOAT32 | ABCD | Read | ||||
| IR | 126doc 30127 | VAh | FLOAT32 | ABCD | Read | ||||
| IR | 132doc 30133 | System Voltage Max | FLOAT32 | ABCD | Read | ||||
| IR | 134doc 30135 | System Voltage Min | FLOAT32 | ABCD | Read | ||||
| IR | 136doc 30137 | RPM | FLOAT32 | ABCD | Read | ||||
| IR | 138doc 30139 | Impulse Rate | FLOAT32 | ABCD | Read | ||||
| IR | 140doc 30141 | System Current Max | FLOAT32 | ABCD | Read | ||||
| IR | 142doc 30143 | System Current Min | FLOAT32 | ABCD | Read | ||||
| IR | 144doc 30145 | Wh imp. depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 146doc 30147 | Wh exp. depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 148doc 30149 | VArh cap. depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 150doc 30151 | VArh ind. depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 152doc 30153 | VAh depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 156doc 30157 | Wh imp OFC depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 158doc 30159 | Wh exp OFC depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 160doc 30161 | VArh Cap. OFC depending on update rate * | FLOAT32 | ABCD | Read | ||||
| IR | 162doc 30163 | VArh Ind. OFC depending on update rate * | FLOAT32 | ABCD | Read | ||||
| IR | 164doc 30165 | VAh OFC depending on update rate* | FLOAT32 | ABCD | Read | ||||
| IR | 168doc 30169 | Re-Active Power Factor L1 | FLOAT32 | ABCD | Read | ||||
| IR | 170doc 30171 | Re-Active Power Factor L2 | FLOAT32 | ABCD | Read | ||||
| IR | 172doc 30173 | Re-Active Power Factor L3 | FLOAT32 | ABCD | Read | ||||
| IR | 174doc 30175 | Average Re-Active Power Factor | FLOAT32 | ABCD | Read | ||||
| IR | 176doc 30177 | Sum Re-Active Power Factor | FLOAT32 | ABCD | Read | ||||
| IR | 178doc 30179 | LF Factor SgnQ(1-(P/S)) L1 | FLOAT32 | ABCD | Read | ||||
| IR | 180doc 30181 | LF Factor SgnQ(1-(P/S)) L2 | FLOAT32 | ABCD | Read | ||||
| IR | 182doc 30183 | LF Factor SgnQ(1-(P/S)) L3 | FLOAT32 | ABCD | Read | ||||
| IR | 184doc 30185 | Average LF Factor SgnQ(1-(P/S)) | FLOAT32 | ABCD | Read | ||||
| IR | 186doc 30187 | Sum LF Factor SgnQ(1-(P/S)) | FLOAT32 | ABCD | Read | ||||
| IR | 188doc 30189 | Displacement Power Factor L1 | FLOAT32 | ABCD | Read | ||||
| IR | 190doc 30191 | Displacement Power Factor L2 | FLOAT32 | ABCD | Read | ||||
| IR | 192doc 30193 | Displacement Power Factor L3 | FLOAT32 | ABCD | Read | ||||
| IR | 194doc 30195 | Average Displacement Power Factor | FLOAT32 | ABCD | Read | ||||
| IR | 196doc 30197 | Sum Displacement Power Factor | FLOAT32 | ABCD | Read | ||||
| IR | 200doc 30201 | V12 | FLOAT32 | ABCD | Read | ||||
| IR | 202doc 30203 | V23 | FLOAT32 | ABCD | Read | ||||
| IR | 204doc 30205 | V31 | FLOAT32 | ABCD | Read | ||||
| IR | 206doc 30207 | VTHD-R | FLOAT32 | ABCD | Read | ||||
| IR | 208doc 30209 | VTHD-Y | FLOAT32 | ABCD | Read | ||||
| IR | 210doc 30211 | VTHD-B | FLOAT32 | ABCD | Read | ||||
| IR | 212doc 30213 | ITHD-R | FLOAT32 | ABCD | Read | ||||
| IR | 214doc 30215 | ITHD-Y | FLOAT32 | ABCD | Read | ||||
| IR | 216doc 30217 | ITHD-B | FLOAT32 | ABCD | Read | ||||
| IR | 218doc 30219 | System V-THD | FLOAT32 | ABCD | Read | ||||
| IR | 220doc 30221 | System I-THD | FLOAT32 | ABCD | Read | ||||
| IR | 224doc 30225 | Neutral Current (3P4W only) | FLOAT32 | ABCD | Read | ||||
| IR | 226doc 30227 | Run hour | FLOAT32 | ABCD | Read | ||||
| IR | 228doc 30229 | On Hour | FLOAT32 | ABCD | Read | ||||
| IR | 230doc 30231 | No. of interrupts | FLOAT32 | ABCD | Read | ||||
| IR | 242doc 30243 | Phase indicate** | FLOAT32 | ABCD | Read | ||||
| IR | 248doc 30249 | VLN Unbalance (3P4W only) | FLOAT32 | ABCD | Read | ||||
| IR | 250doc 30251 | VLL Unbalance (3P4W and 3P3W only) | FLOAT32 | ABCD | Read | ||||
| IR | 252doc 30253 | Curr. Unbalance (3P4W and 3P3W only) | FLOAT32 | ABCD | Read | ||||
| IR | 254doc 30255 | Distortion VAr L1 | FLOAT32 | ABCD | Read | ||||
| IR | 256doc 30257 | Distortion VAr L2 | FLOAT32 | ABCD | Read | ||||
| IR | 258doc 30259 | Distortion VAr L3 | FLOAT32 | ABCD | Read | ||||
| IR | 260doc 30261 | Distortion VAr AVG | FLOAT32 | ABCD | Read | ||||
| IR | 262doc 30263 | Distortion VAr SUM | FLOAT32 | ABCD | Read | ||||
| IR | 264doc 30265 | Fundamental VAr L1 | FLOAT32 | ABCD | Read | ||||
| IR | 266doc 30267 | Fundamental VAr L2 | FLOAT32 | ABCD | Read | ||||
| IR | 268doc 30269 | Fundamental VAr L3 | FLOAT32 | ABCD | Read | ||||
| IR | 270doc 30271 | Fundamental VAr AVG | FLOAT32 | ABCD | Read | ||||
| IR | 272doc 30273 | Fundamental VAr SUM | FLOAT32 | ABCD | Read | ||||
| IR | 274doc 30275 | RTC Complete Date (DDMMYY) | FLOAT32 | ABCD | Read | ||||
| IR | 276doc 30277 | RTC Complete Time (HH:MM 24 Hour format) | FLOAT32 | ABCD | Read | ||||
| IR | 1800doc 31801 | Sys Active Energy Import | FLOAT32 | ABCD | Read | ||||
| IR | 1802doc 31803 | Sys Active Energy Export | FLOAT32 | ABCD | Read | ||||
| IR | 1804doc 31805 | Sys Reactive Energy Capacitive | FLOAT32 | ABCD | Read | ||||
| IR | 1806doc 31807 | Sys Reactive Energy Inductive | FLOAT32 | ABCD | Read | ||||
| IR | 1808doc 31809 | Sys Apparent Energy | FLOAT32 | ABCD | Read | ||||
| IR | 1812doc 31813 | Sys Active Energy Import OVF Count | FLOAT32 | ABCD | Read | ||||
| IR | 1814doc 31815 | Sys Active Energy Export OVF Count | FLOAT32 | ABCD | Read | ||||
| IR | 1816doc 31817 | Sys Reactive Energy Capacitive OVF Count | FLOAT32 | ABCD | Read | ||||
| IR | 1818doc 31819 | Sys Reactive Energy Inductive OVF Count | FLOAT32 | ABCD | Read | ||||
| IR | 1820doc 31821 | Sys Apparent Energy OVF Count | FLOAT32 | ABCD | Read | ||||
| IR | 1824doc 31825 | Sys Active Energy Import on update rate | FLOAT32 | ABCD | Read | ||||
| IR | 1826doc 31827 | Sys Active Energy Export on update rate | FLOAT32 | ABCD | Read | ||||
| IR | 1828doc 31829 | Sys Reactive Energy Capacitive on update rate | FLOAT32 | ABCD | Read | ||||
| IR | 1830doc 31831 | Sys Reactive Energy Inductive on update rate | FLOAT32 | ABCD | Read | ||||
| IR | 1832doc 31833 | Sys Apparent Energy on time | FLOAT32 | ABCD | Read | ||||
| IR | 1836doc 31837 | Sys Active Energy Imp OVF Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1838doc 31839 | Sys Active Energy Exp OVF Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1840doc 31841 | Sys Reactive Energy Cap OVF Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1842doc 31843 | Sys Reactive Energy Ind OVF Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1844doc 31845 | Sys Apparent Energy OVF Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1848doc 31849 | Sys Total Active Energy | FLOAT32 | ABCD | Read | ||||
| IR | 1850doc 31851 | Sys Total Reactive Energy | FLOAT32 | ABCD | Read | ||||
| IR | 1852doc 31853 | Sys Total Apparent Energy | FLOAT32 | ABCD | Read | ||||
| IR | 1854doc 31855 | Sys Total Active Energy OFL Count | FLOAT32 | ABCD | Read | ||||
| IR | 1856doc 31857 | Sys Total Reactive Energy OFL Count | FLOAT32 | ABCD | Read | ||||
| IR | 1858doc 31859 | Sys Total Apparent Energy OFL Count | FLOAT32 | ABCD | Read | ||||
| IR | 1860doc 31861 | Sys Total Active Energy on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1862doc 31863 | Sys Total Reactive Energy on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1864doc 31865 | Sys Total Apparent Energy on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1866doc 31867 | Sys Total Active Energy OFL Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1868doc 31869 | Sys Total Reactive Energy OFL Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1870doc 31871 | Sys Total Apparent Energy OFL Count on update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1872doc 31873 | Active Energy Import L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1874doc 31875 | Active Energy Import L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1876doc 31877 | Active Energy Import L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1878doc 31879 | Active Energy Export L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1880doc 31881 | Active Energy Export L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1882doc 31883 | Active Energy Export L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1884doc 31885 | Reactive Energy Capacitive L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1886doc 31887 | Reactive Energy Capacitive L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1888doc 31889 | Reactive Energy Capacitive L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1890doc 31891 | Reactive Energy Inductive L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1892doc 31893 | Reactive Energy Inductive L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1894doc 31895 | Reactive Energy Inductive L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1896doc 31897 | Apparent Energy L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1898doc 31899 | Apparent Energy L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1900doc 31901 | Apparent Energy L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1908doc 31909 | Total Active Energy L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1910doc 31911 | Total Active Energy L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1912doc 31913 | Total Active Energy L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1914doc 31915 | Total Reactive Energy L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1916doc 31917 | Total Reactive Energy L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1918doc 31919 | Total Reactive Energy L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1920doc 31921 | Total Apparent Energy L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1922doc 31923 | Total Apparent Energy L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1924doc 31925 | Total Apparent Energy L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1926doc 31927 | OVF Count Active Energy Import L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1928doc 31929 | OVF Count Active Energy Import L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1930doc 31931 | OVF Count Active Energy Import L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1932doc 31933 | OVF Count Active Energy Export L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1934doc 31935 | OVF Count Active Energy Export L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1936doc 31937 | OVF Count Active Energy Export L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1938doc 31939 | OVF Count Reactive Energy Capacitive L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1940doc 31941 | OVF Count Reactive Energy Capacitive L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1942doc 31943 | OVF Count Reactive Energy Capacitive L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1944doc 31945 | OVF Count Reactive Energy Inductive L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1946doc 31947 | OVF Count Reactive Energy Inductive L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1948doc 31949 | OVF Count Reactive Energy Inductive L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1950doc 31951 | OVF Count Apparent Energy L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1952doc 31953 | OVF Count Apparent Energy L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1954doc 31955 | OVF Count Apparent Energy L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1962doc 31963 | Total Active Energy OVF Count L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1964doc 31965 | Total Active Energy OVF Count L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1966doc 31967 | Total Active Energy OVF Count L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1968doc 31969 | Total Reactive Energy OVF Count L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1970doc 31971 | Total Reactive Energy OVF Count L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1972doc 31973 | Total Reactive Energy OVF Count L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1974doc 31975 | Total Apparent Energy OVF Count L1 | FLOAT32 | ABCD | Read | ||||
| IR | 1976doc 31977 | Total Apparent Energy OVF Count L2 | FLOAT32 | ABCD | Read | ||||
| IR | 1978doc 31979 | Total Apparent Energy OVF Count L3 | FLOAT32 | ABCD | Read | ||||
| IR | 1980doc 31981 | Active Energy Import L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1982doc 31983 | Active Energy Import L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1984doc 31985 | Active Energy Import L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1986doc 31987 | Active Energy Export L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1988doc 31989 | Active Energy Export L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1990doc 31991 | Active Energy Export L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1992doc 31993 | Reactive Energy Capacitive L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1994doc 31995 | Reactive Energy Capacitive L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1996doc 31997 | Reactive Energy Capacitive L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 1998doc 31999 | Reactive Energy Inductive L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2000doc 32001 | Reactive Energy Inductive L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2002doc 32003 | Reactive Energy Inductive L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2004doc 32005 | Apparent Energy L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2006doc 32007 | Apparent Energy L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2008doc 32009 | Apparent Energy L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2016doc 32017 | Total Active Energy L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2018doc 32019 | Total Active Energy L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2020doc 32021 | Total Active Energy L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2022doc 32023 | Total Reactive Energy L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2024doc 32025 | Total Reactive Energy L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2026doc 32027 | Total Reactive Energy L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2028doc 32029 | Total Apparent Energy L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2030doc 32031 | Total Apparent Energy L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2032doc 32033 | Total Apparent Energy L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2034doc 32035 | OVF Active Energy Import L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2036doc 32037 | OVF Active Energy Import L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2038doc 32039 | OVF Active Energy Import L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2040doc 32041 | OVF Active Energy Export L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2042doc 32043 | OVF Active Energy Export L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2044doc 32045 | OVF Active Energy Export L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2046doc 32047 | OVF Reactive Energy Capacitive L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2048doc 32049 | OVF Reactive Energy Capacitive L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2050doc 32051 | OVF Reactive Energy Capacitive L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2052doc 32053 | OVF Reactive Energy Inductive L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2054doc 32055 | OVF Reactive Energy Inductive L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2056doc 32057 | OVF Reactive Energy Inductive L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2058doc 32059 | OVF Apparent Energy L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2060doc 32061 | OVF Apparent Energy L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2062doc 32063 | OVF Apparent Energy L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2070doc 32071 | Total Active Energy OVF Count L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2072doc 32073 | Total Active Energy OVF Count L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2074doc 32075 | Total Active Energy OVF Count L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2076doc 32077 | Total Reactive Energy OVF Count L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2078doc 32079 | Total Reactive Energy OVF Count L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2080doc 32081 | Total Reactive Energy OVF Count L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2082doc 32083 | Total Apparent Energy OVF Count L1 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2084doc 32085 | Total Apparent Energy OVF Count L2 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2086doc 32087 | Total Apparent Energy OVF Count L3 On Update Rate* | FLOAT32 | ABCD | Read | ||||
| IR | 2088doc 32089 | Digital Input Pulse Counter 1 Value | FLOAT32 | ABCD | Read | ||||
| IR | 2090doc 32091 | Digital Input Pulse Counter 2 Value | FLOAT32 | ABCD | Read | ||||
| IR | 2092doc 32093 | Digital Input Pulse Counter 3 Value | FLOAT32 | ABCD | Read | ||||
| IR | 2094doc 32095 | Digital Input Pulse Counter 4 Value | FLOAT32 | ABCD | Read | ||||
| IR | 2096doc 32097 | Digital Input Pulse Counter 1 Overflow | FLOAT32 | ABCD | Read | ||||
| IR | 2098doc 32099 | Digital Input Pulse Counter 2 Overflow | FLOAT32 | ABCD | Read | ||||
| IR | 2100doc 32101 | Digital Input Pulse Counter 3 Overflow | FLOAT32 | ABCD | Read | ||||
| IR | 2102doc 32103 | Digital Input Pulse Counter 4 Overflow | FLOAT32 | ABCD | Read | ||||
| IR | 2104doc 32105 | Run Hour Utility | FLOAT32 | ABCD | Read | ||||
| IR | 2106doc 32107 | On Hour Utility | FLOAT32 | ABCD | Read | ||||
| IR | 2112doc 32113 | No of Interruption | FLOAT32 | ABCD | Read | ||||
| HR | 6002doc 46003 | System Type | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6004doc 46005 | PT Primary | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6006doc 46007 | CT Primary | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6008doc 46009 | PT Secondary | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6010doc 46011 | CT Secondary | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6018doc 46019 | Demand Integration Time | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6036doc 46037 | Reset Parameters | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6038doc 46039 | Password | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6046doc 46047 | Auto Scroll | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6050doc 46051 | Node Address | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6052doc 46053 | RS485 Setup Code | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6054doc 46055 | Register Order/Word Order | Setup parameter (float). | FLOAT32 | ABCD | Read/write | |||
| HR | 6356doc 46357 | Firmware Version Number | Read-only identification value (float). | FLOAT32 | ABCD | Read |
Notes on this map
- Measured values are IEEE-754 32-bit floats in two registers. The manual's example responses (e.g. data bytes 43 5B 41 21 for a current reading) put the most significant register first, so ABCD is the default order.
- Register 46055 (Word Order) can switch the meter to reversed register order; the manual says to write 2141.0 to it and the meter detects which order was used. If floats look wrong, check this setting.
- Every measured value is also readable as a holding register (FC03) at the 4X address printed next to it in the manual; this map lists the 3X (input register, FC04) copies only.
- Rows whose printed hex address does not match the decimal 3X/4X address in the manual were left out rather than guessed.
- Left out: the 32-bit integer energy tables (their integer word order is not demonstrated in the manual), user-assignable registers and data-log blocks.
- Where the register table has no unit column, units are left blank; energy registers follow the energy unit (Wh/kWh/MWh) configured on the meter, and 'OF' / overflow registers count roll-overs of the matching energy register.
- Left out for size: min/max values (Table 1.2), individual harmonics (Table 1.4), old parameters, digital I/O and tariff tables, and data-log blocks.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Rishabh Instruments RISH LM 1380 multifunction meter
What Modbus registers does the Rishabh Instruments RISH LM 1380 multifunction meter have?
This map lists 277 registers: 264 input registers, 13 holding registers. 12 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Rishabh Instruments RISH LM 1380 multifunction meter Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The manual prints 30001/40001-style addresses next to the hex start address actually sent (30001 = 0x0000). Wire address = printed number - 30001 (input registers) or - 40001 (holding registers); every value here was cross-checked against the printed hex address.
What byte order does the Rishabh Instruments RISH LM 1380 multifunction meter use for 32-bit values?
Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.
What are the minimum Modbus registers to integrate the Rishabh Instruments RISH LM 1380 multifunction meter?
Start with IR 0 Voltage L1 (Voltage L12 for 3P3W) (Voltage L1); IR 6 Current L1 (Current L1); IR 52 Watt Sum (Total active power (Watt Sum)); IR 70 Freq (Frequency); IR 62 PF Avg (Average power factor); IR 1800 Sys Active Energy Import (System active energy import); IR 72 Wh import (Active energy import (Wh import)).
How do I enable Modbus control of the Rishabh Instruments RISH LM 1380 multifunction meter?
Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.
Where is the official Rishabh Instruments RISH LM 1380 multifunction meter Modbus documentation?
The source is Rish LM1380 Interface Manual (DMAN-00IM-0925 Rev. A), revision 2022-04, published free by Rishabh Instruments at https://rishabh.co.in/uploads/product/rish-lm1380-96/Rish_LM1380_Interface_Manual.pdf.
More Rishabh Instruments Modbus register maps
- Energy meter (DC)
Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter
Rishabh RISH DC2111 MOD single-channel DC energy meters with RS-485 Modbus, per interface definition DMAN-00IM-1669 Rev. D (08/25).
Also known as: RISH DC2111 MOD, DC2111 - Energy meter
Rishabh Instruments RISH Delta Energy NX multifunction energy meter
Rishabh RISH Delta Energy NX panel energy meters with RS-485 Modbus RTU, per the operating manual on the product page (standard CT version).
Also known as: RISH Delta Energy NX, Delta Energy NX, RISH Delta Energy - Power meter
Rishabh Instruments RISH Delta Power NX multifunction power meter
Rishabh RISH Delta Power NX programmable panel meters with RS-485 Modbus RTU, per operating manual AMAN-00IM-0117 Rev. E.
Also known as: RISH Delta Power NX, Delta Power NX, RISH Delta Power - Power meter
Rishabh Instruments RISH Delta VAF NX volt/amp/frequency panel meter
Rishabh RISH Delta VAF NX programmable panel meters with RS-485 Modbus RTU, per operating manual AMAN-00IM-0118 Rev. F.
Also known as: RISH Delta VAF NX, Delta VAF NX, RISH Delta VAF - Power meter (demand controller)
Rishabh Instruments RISH DMCi touch-screen demand controller with TOD
Rishabh RISH DMCi 96 x 96 mm touch-screen demand controllers with the optional RS-485 Modbus output, per interface definition DMAN-00IM-0578 Rev. A (09/16).
Also known as: RISH DMCi, DMCi, Rish DMCi demand controller - Energy meter
Rishabh Instruments RISH EC43xx / ER43xx DIN-rail energy meters
Rishabh RISH EC43xx and ER43xx DIN-rail digital energy meters with RS-485 Modbus, per interface definition DMAN-00IM-09xx Rev. F (11/25).
Also known as: EC4311, EC4321, ER4311, ER4321, RISH EC43X1, EC43XX, ER43XX - Energy meter
Rishabh Instruments RISH ED11XX / EC11XX / ER11XX single-phase DIN-rail energy meters
Rishabh RISH ED11XX (direct), EC11XX (CT) and ER11XX (RJ12 CT) single-phase DIN-rail meters in their Modbus (x1) versions, per operating manual DMAN-00IM-1071 Rev. M.
Also known as: RISH ED11X1, RISH EC11X1, RISH ER11X1, ED1111, EC1111, ER1111, RISH ED11XX, RISH EC11XX, RISH ER11XX - Energy meter
Rishabh Instruments RISH ED21XX / EC21XX / ER21XX single-phase energy meters
Rishabh RISH ED21XX (direct), EC21XX (CT) and ER21XX (RJ12 CT) single-phase meters in their Modbus versions, per operating manual DMAN-00IM-1073 Rev. M.
Also known as: RISH ED21X1, RISH EC21X1, RISH ER21X1, RISH ED21XX, RISH EC21XX, RISH ER21XX - Energy meter
Rishabh Instruments RISH EM 1320 / 1330 / 1340 / 2340 programmable energy meters
Rishabh RISH EM 1320/1330/1340 and EM 2320/2330/2340 panel energy meters with RS-485 Modbus, per interface definition DMAN-00IM-0721 Rev. B (06/2020). Rows marked 'only 2340' apply to the dual-source EM 2340.
Also known as: RISH EM 1320, RISH EM 1330, RISH EM 1340, RISH EM 2320, RISH EM 2330, RISH EM 2340, EM2340DS - Energy meter
Rishabh Instruments RISH EM 3490 DS dual-source (utility/generator) energy meter
Rishabh RISH EM 3490 DS dual-source energy meters (separate utility and generator energy) with RS-485 Modbus, per manual Rev G.
Also known as: RISH EM 3490 DS, EM3490DS, EM 3490DS - Energy meter
Rishabh Instruments RISH EM 3490 SS single-phase energy meter
Rishabh RISH EM 3490 SS single-phase energy meters with the optional RS-485 Modbus output, per the 1-phase manual Rev D.
Also known as: RISH EM 3490 SS 1P, EM3490SS 1P, EM 3490 SS single-phase - Energy meter
Rishabh Instruments RISH EM 3490 SS three-phase single-source energy meter
Rishabh RISH EM 3490 SS three-phase energy meters with the optional RS-485 Modbus output, per the 3-phase manual Rev E.
Also known as: RISH EM 3490 SS 3P, EM3490SS 3P, EM 3490 SS three-phase - Energy meter (DC)
Rishabh Instruments RISH EM DC 6000 programmable DC energy meter
Rishabh RISH EM DC 6000 single-channel programmable DC energy meters with RS-485 Modbus, per interface definition DMAN-00IM-0862 Rev. 0 (12/2020).
Also known as: RISH EM DC 6000, EMDC 6000, EM DC6000 - Energy meter (DC)
Rishabh Instruments RISH EM DC 6001 / 6002 multi-channel DC energy meter
Rishabh RISH EM DC 6001 / 6002 multi-channel DC energy meters with RS-485 Modbus, per interface definition 2-60-006-00-00627 Rev. 0 (10/2015).
Also known as: RISH EM DC 6001, RISH EM DC 6002, EM DC 6001, EM DC 6002 - Power meter
Rishabh Instruments RISH LM 1340 multifunction meter
Rishabh RISH LM 1340 panel multifunction instruments with RS-485 Modbus, per interface definition DMAN-00IM-0923 Rev. D (03/2026).
Also known as: RISH LM 1340, LM1340 - Power meter
Rishabh Instruments RISH LM 1360 load manager (LM 13xx)
Rishabh RISH LM 1360 panel meters with RS-485 Modbus, per interface definition DMAN-00IM-0662 Rev. D (01/2024).
Also known as: RISH LM 1360, LM1360, LM 13xx, LM1360 RJ12 - Power meter
Rishabh Instruments RISH LM1360+ RJ12 smart energy meter
Rishabh RISH LM1360 PLUS RJ12 smart energy meters (RJ12 CT inputs) with RS-485 Modbus, per interface definition DMAN-00IM-0923 Rev. A (01/2026).
Also known as: RISH LM 1360+, LM1360 PLUS RJ12, LM1360+ - Power meter
Rishabh Instruments RISH Master 3440 (class 0.2S) multifunction meter
Rishabh RISH Master 3440 class 0.2S panel meters with RS-485 Modbus, per interface definition DMAN-00IM-0711 Rev. C (05/2019).
Also known as: RISH Master 3440, RM3440, Master 3440 0.2S - Power meter
Rishabh Instruments RISH Master 3440i / 3440iDL (class 0.2S) touch-screen meter
Rishabh RISH Master 3440i and 3440iDL touch-screen class 0.2S meters with RS-485 Modbus, per interface definition DMAN-00IM-0712 Rev. F (10/2026).
Also known as: RISH Master 3440i, RISH Master 3440iDL, RM3440i, RM3440iDL - Power meter (multi-circuit energy meter)
Rishabh Instruments RISH ML 1400 / ML 1410 Multiload Monitor (Modbus RTU)
RISH Multiload Monitor (12 current channels, 4 voltage channels) per interface definition DMAN-00IM-0795 Rev A (08/2020).
Also known as: RISH ML 1400, RISH ML 1410, RISH MLM, Multiload Monitor - Power meter (power factor controller)
Rishabh Instruments RISH PFC 96 / PFC 144 automatic power factor controller
Rishabh RISH PFC 96 and PFC 144 automatic power factor (APFC) controllers with RS-485 Modbus RTU, per interface definition version D (12/18).
Also known as: RISH PFC 96, RISH PFC 144, PFC96, PFC144, RISH PFC-12, APFC
Other power & energy meters register maps
- Power meter (multi-circuit branch feeder monitor)
SATEC BFM-II branch feeder monitor
SATEC BFM-II multi-circuit meter per Modbus reference guide BG0589 Rev. A12 (May 2024); per-submeter 32-bit measurement registers plus shared setup.
Also known as: BFM II, BFM2, SATEC BFM-II - Energy meter (pulse and status concentrator)
Schneider Electric Acti 9 Smartlink Modbus (A9XMSB11) 11-channel I/O and pulse concentrator
Acti 9 Smartlink Modbus RS-485 module A9XMSB11, per user manual DOCA0004EN-06 (04/2016).
Also known as: Acti 9 Smartlink, Smartlink Modbus, A9XMSB11, Acti9 Smartlink - Energy meter
Siemens SENTRON PAC2200
SENTRON 7KM PAC2200 Modbus TCP and Modbus RTU variants (5 A and 65 A), per Equipment Manual 12/2022.
Also known as: 7KM PAC2200 - Energy meter (Ethernet energy monitoring / data logger)
Teracom TCW260 Ethernet energy monitoring module
TCW260 per the Teracom TCW260 user manual Revision R1.19, firmware V3.009 or later.
Also known as: TCW260 - Energy meter
ABB EQ meter B21 (Modbus RTU)
ABB EQ B21 single-phase 65 A DIN meter with the RS485 interface set to Modbus.
Also known as: B21, EQ B21 - Power meter
Accuenergy Acuvim II Series
Accuenergy Acuvim II series multifunction power meters (manual 1040E1303, V3.2.16 revised September 2026).
Also known as: Acuvim IIR, Acuvim IIW
All power & energy meters Modbus register maps →
Source: Rish LM1380 Interface Manual · DMAN-00IM-0925 Rev. A · rev. 2022-04. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.