Energy meter (DC) · Modbus register map

Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter Modbus register map

Updated 17 November 2026

Short answer

The RISH DC2111 MOD is a DIN-rail DC energy meter for one DC channel. Its RS-485 port speaks Modbus RTU with every reading as a 32-bit float. This map covers voltage, current, power, import/export energy and ampere-hours with their overflow counters, demands, min/max values, hour counters and the basic communication settings.

This page lists 52 Modbus registers for the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter — 4 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Rishabh Instruments’s own free documentation (linked below) and checked against it.

Manufacturer
Rishabh Instruments
Model
RISH DC2111 MOD single-channel DC energy meter
Equipment type
Energy meter (DC)
Registers
52 (4 writable)
Transport
Modbus RTU
Default unit ID
1
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
32-bit word order
ABCD high word first (big-endian)
Also known as
RISH DC2111 MOD, DC2111
Source document
RISH DC2111 MOD - Interface Definition Manual · DMAN-00IM-1669 Rev. D · rev. 2025-08
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter

Integration in brief

Read measured values with FC04 (or FC03 at the 4X copies) in pairs of registers and decode them as ABCD floats. Settings are floats too and are written with FC16.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 0VoltageFLOAT32 ABCDDC voltageRead
IR 2CurrentFLOAT32 ABCDDC currentRead
IR 4PowerFLOAT32 ABCDDC powerRead
IR 6Import EnergyFLOAT32 ABCDImport energyRead
IR 10Export EnergyFLOAT32 ABCDExport energyRead
IR 14Import Ampere HourFLOAT32 ABCDImport ampere-hoursRead

Enable Modbus control & writes

Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.

Byte order & addressing

Network setup

Watch out for

Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

52 of 52 shown
Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
IR0doc 30001VoltageDC voltage.FLOAT32ABCDVRead
IR2doc 30003CurrentDC current.FLOAT32ABCDARead
IR4doc 30005PowerDC power (manual's example: 2000 W).FLOAT32ABCDWRead
IR6doc 30007Import EnergyFLOAT32ABCDRead
IR8doc 30009Import Energy OFFLOAT32ABCDRead
IR10doc 30011Export EnergyFLOAT32ABCDRead
IR12doc 30013Export Energy OFFLOAT32ABCDRead
IR14doc 30015Import Ampere HourFLOAT32ABCDRead
IR16doc 30017Import Ampere Hour OFFLOAT32ABCDRead
IR18doc 30019Export Ampere HourFLOAT32ABCDRead
IR20doc 30021Export Ampere Hour OFFLOAT32ABCDRead
IR22doc 30023Import Power DemandFLOAT32ABCDRead
IR24doc 30025Export Power DemandFLOAT32ABCDRead
IR26doc 30027Import Current DemandFLOAT32ABCDRead
IR28doc 30029Export Current DemandFLOAT32ABCDRead
IR30doc 30031Max VoltageFLOAT32ABCDRead
IR32doc 30033Min VoltageFLOAT32ABCDRead
IR34doc 30035Max CurrentFLOAT32ABCDRead
IR36doc 30037Min CurrentFLOAT32ABCDRead
IR38doc 30039Max Import Power DemandFLOAT32ABCDRead
IR40doc 30041Max Export Power DemandFLOAT32ABCDRead
IR42doc 30043Max Import Current DemandFLOAT32ABCDRead
IR44doc 30045Max Export Current DemandFLOAT32ABCDRead
IR46doc 30047Import Energy on update rateFLOAT32ABCDRead
IR48doc 30049Import Energy on update rate OFFLOAT32ABCDRead
IR50doc 30051Export Energy on update rateFLOAT32ABCDRead
IR52doc 30053Export Energy on update rate OFFLOAT32ABCDRead
IR54doc 30055On HourFLOAT32ABCDRead
IR56doc 30057Run HourFLOAT32ABCDRead
IR58doc 30059No. of InterruptionsFLOAT32ABCDRead
IR60doc 30061Partial Import EnergyFLOAT32ABCDRead
IR62doc 30063Partial Import Energy OFFLOAT32ABCDRead
IR64doc 30065Partial Export EnergyFLOAT32ABCDRead
IR66doc 30067Partial Export Energy OFFLOAT32ABCDRead
IR68doc 30069Partial Import Ampere HourFLOAT32ABCDRead
IR70doc 30071Partial Import Ampere Hour OFFLOAT32ABCDRead
IR72doc 30073Partial Export Ampere HourFLOAT32ABCDRead
IR74doc 30075Partial Export Ampere Hour OFFLOAT32ABCDRead
IR76doc 30077Max PowerFLOAT32ABCDRead
IR78doc 30079Min PowerFLOAT32ABCDRead
IR80doc 30081Total energyFLOAT32ABCDRead
IR82doc 30083Total energy OFFLOAT32ABCDRead
IR88doc 30089Total Ampere HourFLOAT32ABCDRead
IR90doc 30091Total Ampere Hour OFFLOAT32ABCDRead
IR96doc 30097Partial Total energyFLOAT32ABCDRead
IR98doc 30099Partial Total energy OFFLOAT32ABCDRead
IR104doc 30105Partial Total Ampere HourFLOAT32ABCDRead
IR106doc 30107Partial Total Ampere Hour OFFLOAT32ABCDRead
HR2doc 40003Demand PeriodDemand period in minutes (5, 10, 15, 30 or 60).FLOAT32ABCDRead/write
HR4doc 40005Reset parametersWrite a code to reset counters (see manual Table 5).FLOAT32ABCDRead/write
HR6doc 40007RS485 Setup CodeBaud rate / parity / stop bit code (manual Table 6).FLOAT32ABCDRead/write
HR8doc 40009Modbus addressModbus slave address, 1-247.FLOAT32ABCDRead/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter

What Modbus registers does the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter have?

This map lists 52 registers: 48 input registers, 4 holding registers. 4 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The manual prints 30001/40001-style addresses next to the hex start address actually sent (30001 = 0x0000). Wire address = printed number - 30001 (input registers) or - 40001 (holding registers); every value here was cross-checked against the printed hex address.

What byte order does the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter?

Start with IR 0 Voltage (DC voltage); IR 2 Current (DC current); IR 4 Power (DC power); IR 6 Import Energy (Import energy); IR 10 Export Energy (Export energy); IR 14 Import Ampere Hour (Import ampere-hours).

How do I enable Modbus control of the Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter?

Modbus RTU on RS-485 is built in; set the slave address, baud rate and parity from the meter's setup menu or the RS-485 setup register.

Where is the official Rishabh Instruments RISH DC2111 MOD single-channel DC energy meter Modbus documentation?