Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) Modbus register map

Updated 17 November 2026

Short answer

The Trafag 8775 sensor and 879x hybrid monitor measure the density of a specified gas or gas mixture with a pair of quartz oscillators, and report it over Modbus RTU. This map is the manual's 'Legacy' configuration: scaled 16-bit density, pressure and temperature, identification, serial settings and a sensor-status discrete input.

This page lists 13 Modbus registers for the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) — 4 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Trafag’s own free documentation (linked below) and checked against it.

Manufacturer
Trafag
Model
8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map)
Equipment type
Sensor (gas density)
Registers
13 (4 writable)
Transport
Modbus RTU
Default unit ID
Not stated
Documented addressing
0-based (the number printed is the address on the wire)
32-bit word order
ABCD high word first (big-endian)
Also known as
8775, 8791, 8792, 8793, 879x, Trafag gas density monitor
Source document
Software Instruction Sensor/Monitor - 8775 Gas Density Sensor, 879x Hybrid Gas Density Monitor · H73622a · rev. 2025-10
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map)

Integration in brief

Read input registers 0-3 (function 04) for density, pressure and temperature as scaled integers, and discrete input 0 (function 02) for sensor status.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
IR 0Gas densityUINT16Gas density, kg/m3 x 0.01Read
IR 1Gas pressure (abs, @20°C)UINT16Pressure @20°C, kPa x 0.1Read
IR 2Gas temperatureUINT16Gas temperature, K x 0.1Read
DI 0Sensor statusBITSensor error flagRead

Enable Modbus control & writes

Modbus RTU is always active. Server ID, baud rate and parity are holding registers 2-5; register 8 shows which of them are write-protected.

Byte order & addressing

Network setup

Watch out for

Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

13 of 13 shown
Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
DI0Sensor status0 = working properly, 1 = sensor error.BITRead
IR0Gas density0xFFFF when out of range.UINT16× 0.01kg/m3Read
IR1Gas pressure (abs, @20°C)0xFFFF when out of range.UINT16× 0.1kPaRead
IR2Gas temperatureUINT16× 0.1KRead
IR3Gas pressure (abs, at gas temperature)0xFFFF when out of range.UINT16× 0.1kPaRead
IR4Server ID1-247.UINT16Read
IR5doc 5+6Serial numberBig-endian; e.g. 0x075BCD15 = 123456-789.UINT32ABCDRead
IR7Firmware release versionUINT16× 0.01Read
HR2Server ID1-247.UINT16Read/write
HR3doc 3+4Baud rate1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 56000 or 57600.UINT32ABCDbaudRead/write
HR5ParityUINT16Read/write0 = None (2 stop bits); 1 = Odd (1 stop bit); 2 = Even (1 stop bit)
HR7Change to bootloaderUINT16Read/write1 = Enter bootloader mode for 10 s
HR8Write permissionsBit = 0 means writable, 1 means locked.BITMAP16Readbit 0 = Server ID locked; bit 1 = Baud rate locked; bit 2 = Parity locked

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map)

What Modbus registers does the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) have?

This map lists 13 registers: 1 discrete input, 7 input registers, 5 holding registers. 4 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers 0-based (the number printed is the address on the wire). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Addresses are protocol addresses. The manual's example reads density (address 0) with start address 0x0000 and the serial number (address 5) with 0x0005.

What byte order does the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) use for 32-bit values?

Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map)?

Start with IR 0 Gas density (Gas density, kg/m3 x 0.01); IR 1 Gas pressure (abs, @20°C) (Pressure @20°C, kPa x 0.1); IR 2 Gas temperature (Gas temperature, K x 0.1); DI 0 Sensor status (Sensor error flag).

How do I enable Modbus control of the Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map)?

Modbus RTU is always active. Server ID, baud rate and parity are holding registers 2-5; register 8 shows which of them are write-protected.

Where is the official Trafag 8775 gas density sensor / 879x hybrid gas density monitor (legacy Modbus map) Modbus documentation?

The source is Software Instruction Sensor/Monitor - 8775 Gas Density Sensor, 879x Hybrid Gas Density Monitor (H73622a), revision 2025-10, published free by Trafag at https://media.trafag.com/instruction/H73622a_87xx_Software-Instruction-Density-Sensor_A4.pdf.

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: Software Instruction Sensor/Monitor - 8775 Gas Density Sensor, 879x Hybrid Gas Density Monitor · H73622a · rev. 2025-10. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.