  4. XMP10 humidity and temperature probe (Modbus RTU)

Sensor (humidity and temperature probe) · Modbus register map

Vaisala XMP10 humidity and temperature probe (Modbus RTU) Modbus register map

Updated 19 November 2026

Short answer

XMP10 is a small Vaisala HUMICAP humidity and temperature probe that works stand-alone or as the sensing part of a transmitter such as Origo10. With the Modbus option it talks Modbus RTU on RS-485 and can be daisy-chained. This map covers humidity, temperature and the calculated humidity values as floats and scaled integers, error and status registers, filtering, serial settings and the test registers.

This page lists 26 Modbus registers for the Vaisala XMP10 humidity and temperature probe (Modbus RTU) — 7 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Vaisala’s own free documentation (linked below) and checked against it.

Manufacturer
Vaisala
Model
XMP10 humidity and temperature probe (Modbus RTU)
Equipment type
Sensor (humidity and temperature probe)
Registers
26 (7 writable)
Transport
Modbus RTU
Default unit ID
240
Default serial
19200 baud, 8N2
Documented addressing
1-based (subtract 1 for the wire address)
32-bit word order
CDAB low word first (word-swapped)
Also known as
XMP10, HUMICAP XMP10, Vaisala XMP10
Source document
XMP10 User Guide · M213279EN-A · rev. 2026-04
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Vaisala XMP10 humidity and temperature probe (Modbus RTU)

Integration in brief

Read holding registers 1-4 (wire 0-3) for RH and temperature as low-word-first floats, or 257-258 as integers divided by 10. Check register 513 and the error code at 516 for faults.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 0Relative humidityFLOAT32 CDABRelative humidityRead
HR 2TemperatureFLOAT32 CDABTemperatureRead
HR 8Dew/frost point temperatureFLOAT32 CDABDew/frost pointRead
HR 26EnthalpyFLOAT32 CDABEnthalpyRead
HR 512Error statusINT16Error statusRead
HR 515Error codeINT32 CDABError codeRead

Enable Modbus control & writes

Order the probe with Modbus RTU output (output code M), or from the serial command interface give smode modbus and then reset or power cycle the probe. Serial setting changes also need a power cycle before they apply.

Byte order & addressing

Network setup

Watch out for

Vaisala XMP10 humidity and temperature probe (Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

26 of 26 shown
Vaisala XMP10 humidity and temperature probe (Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
HR0doc 1Relative humidityFLOAT32CDAB%RHRead
HR2doc 3TemperatureFLOAT32CDAB°CRead
HR8doc 9Dew/frost point temperatureFLOAT32CDAB°CRead
HR14doc 15Absolute humidityFLOAT32CDABg/m3Read
HR16doc 17Mixing ratioFLOAT32CDABg/kgRead
HR18doc 19Wet-bulb temperatureFLOAT32CDAB°CRead
HR26doc 27EnthalpyFLOAT32CDABkJ/kgRead
HR256doc 257Relative humidity (integer)INT16× 0.1%RHRead
HR257doc 258Temperature (integer)INT16× 0.1°CRead
HR260doc 261Dew/frost point temperature (integer)INT16× 0.1°CRead
HR263doc 264Absolute humidity (integer)INT16× 0.1g/m3Read
HR264doc 265Mixing ratio (integer)INT16× 0.1g/kgRead
HR265doc 266Wet-bulb temperature (integer)INT16× 0.1°CRead
HR269doc 270Enthalpy (integer)INT16× 0.1kJ/kgRead
HR512doc 513Error statusINT16Read0 = One or more errors active; 1 = No errors
HR515doc 516Error codeSum of active error codes (see bits).INT32CDABReadbit 0 = Temperature measurement error; bit 1 = Humidity measurement error; bit 2 = Humidity sensor failure; bit 3 = Capacitance reference error; bit 4 = Ambient temperature out of range; bit 5 = Firmware checksum mismatch; bit 6 = Device settings corrupted; bit 7 = Additional configuration settings corrupted; bit 8 = Sensor coefficients corrupted; bit 9 = Main configuration settings corrupted; bit 11 = Supply voltage out of range; bit 13 = Non-volatile memory read/write failure
HR517doc 518Security hashChanges whenever settings or adjustments change.INT32CDABRead
HR784doc 785Measurement filtering factor0.001 = maximum filtering, 1.000 = no filtering.FLOAT32CDABRead/write
HR1536doc 1537Modbus address1-247.INT16Read/write
HR1537doc 1538Bit rateTakes effect after restart.INT16Read/write5 = 9600; 6 = 19200; 7 = 38400; 8 = 57600
HR1538doc 1539Parity, data, stop bitsTakes effect after restart.INT16Read/write0 = None, 8, 1; 1 = None, 8, 2; 2 = Even, 8, 1; 3 = Even, 8, 2; 4 = Odd, 8, 1; 5 = Odd, 8, 2
HR1539doc 1540Response delay0-1020 ms in 4 ms steps.INT16msRead/write
HR1540doc 1541ProtocolINT16Read/write6 = Modbus RTU
HR1541doc 1542Restart deviceWrite 1 to restart.INT16Write
HR7936doc 7937Signed integer testAlways reads -12345.INT16Read
HR7937doc 7938Floating point testAlways reads -123.45.FLOAT32CDABRead

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Vaisala XMP10 humidity and temperature probe (Modbus RTU)

What Modbus registers does the Vaisala XMP10 humidity and temperature probe (Modbus RTU) have?

This map lists 26 registers: 26 holding registers. 7 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Vaisala XMP10 humidity and temperature probe (Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers 1-based (subtract 1 for the wire address). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The guide numbers registers in decimal from 1 and also prints the 0-based hex address used in the request. Register 1 is address 0x0000 on the wire; the guide's example frame reads relative humidity at address 0x0000.

What byte order does the Vaisala XMP10 humidity and temperature probe (Modbus RTU) use for 32-bit values?

Multi-register values in this map use CDAB (low word first (word-swapped)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Vaisala XMP10 humidity and temperature probe (Modbus RTU)?

Start with HR 0 Relative humidity (Relative humidity); HR 2 Temperature (Temperature); HR 8 Dew/frost point temperature (Dew/frost point); HR 26 Enthalpy (Enthalpy); HR 512 Error status (Error status); HR 515 Error code (Error code).

How do I enable Modbus control of the Vaisala XMP10 humidity and temperature probe (Modbus RTU)?

Order the probe with Modbus RTU output (output code M), or from the serial command interface give smode modbus and then reset or power cycle the probe. Serial setting changes also need a power cycle before they apply.

Where is the official Vaisala XMP10 humidity and temperature probe (Modbus RTU) Modbus documentation?

The source is XMP10 User Guide (M213279EN-A), revision 2026-04, published free by Vaisala at https://docs.vaisala.com/r/M213279EN-A/en-US.

More Vaisala Modbus register maps

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: XMP10 User Guide · M213279EN-A · rev. 2026-04. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.