Sensor (ultrasonic wind) · Modbus register map

Vaisala WM80 ultrasonic wind sensor (Modbus RTU) Modbus register map

Updated 19 November 2026

Short answer

The Vaisala WM80 is a heated ultrasonic wind sensor aimed at uses that need continuous wind data, such as wind turbine control, ship navigation and dynamic positioning. On RS-485 it serves Modbus RTU or an ASCII/NMEA message. This map covers wind speed and direction (sample, instant, average, gust, lull, U/V components), sonic temperature, averaging and heating settings, serial settings, status words, monitoring values and test registers.

This page lists 47 Modbus registers for the Vaisala WM80 ultrasonic wind sensor (Modbus RTU) — 15 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Vaisala’s own free documentation (linked below) and checked against it.

Manufacturer
Vaisala
Model
WM80 ultrasonic wind sensor (Modbus RTU)
Equipment type
Sensor (ultrasonic wind)
Registers
47 (15 writable)
Transport
Modbus RTU
Default unit ID
240
Default serial
19200 baud, 8N2
Documented addressing
hexadecimal, 0-based
32-bit word order
CDAB low word first (word-swapped)
Also known as
WM80, Vaisala WM80, Ultrasonic Wind Sensor WM80
Source document
WM80 User Guide · M212995EN-F · rev. 2025-12
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: Vaisala WM80 ultrasonic wind sensor (Modbus RTU)

Integration in brief

Read holding registers 0x0000-0x0015 in one request for speed, direction, gust, lull and sonic temperature as low-word-first floats, and check the status words at 0x0200-0x0209.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 4Wind speed, instantFLOAT32 CDABInstant wind speedRead
HR 6Wind direction, instantFLOAT32 CDABInstant wind directionRead
HR 8Wind speed, averageFLOAT32 CDABAverage wind speedRead
HR 14Wind speed, gustFLOAT32 CDABGustRead
HR 512Device statusBITMAP16Device statusRead
HR 521Wind measurement statusBITMAP16Wind measurement statusRead

Enable Modbus control & writes

Order the sensor with the Modbus RTU communication profile (option C), or in Vaisala Insight PC software select Communication, set Interface mode to Modbus RTU, save, then power-cycle the sensor. Interface mode is also register 0x0605.

Byte order & addressing

Network setup

Watch out for

Vaisala WM80 ultrasonic wind sensor (Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

47 of 47 shown
Vaisala WM80 ultrasonic wind sensor (Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
HR0doc 0x0000 (0)Wind speed, sample10 Hz sample.FLOAT32CDABm/sRead
HR2doc 0x0002 (2)Wind direction, sampleFLOAT32CDABdegRead
HR4doc 0x0004 (4)Wind speed, instantMoving average over the instant averaging period.FLOAT32CDABm/sRead
HR6doc 0x0006 (6)Wind direction, instantFLOAT32CDABdegRead
HR8doc 0x0008 (8)Wind speed, averageMoving average over the statistics period.FLOAT32CDABm/sRead
HR10doc 0x000a (10)Wind direction, averageFLOAT32CDABdegRead
HR12doc 0x000c (12)Wind speed, lullMinimum instant speed over the statistics period.FLOAT32CDABm/sRead
HR14doc 0x000e (14)Wind speed, gustMaximum instant speed over the statistics period.FLOAT32CDABm/sRead
HR16doc 0x0010 (16)Wind direction, lullFLOAT32CDABdegRead
HR18doc 0x0012 (18)Wind direction, gustFLOAT32CDABdegRead
HR20doc 0x0014 (20)Sonic temperatureFLOAT32CDAB°CRead
HR22doc 0x0016 (22)Wind speed U, sampleFLOAT32CDABm/sRead
HR24doc 0x0018 (24)Wind speed V, sampleFLOAT32CDABm/sRead
HR26doc 0x001a (26)Wind speed U, instantFLOAT32CDABm/sRead
HR28doc 0x001c (28)Wind speed V, instantFLOAT32CDABm/sRead
HR30doc 0x001e (30)Wind speed U, averageFLOAT32CDABm/sRead
HR32doc 0x0020 (32)Wind speed V, averageFLOAT32CDABm/sRead
HR512doc 0x0200 (512)Device status0 = device OK.BITMAP16Readbit 2 = Warning (W)
HR515doc 0x0203 (515)Operating voltage status0 = operating voltage OK.BITMAP16Readbit 2 = Operating voltage too low (U); bit 3 = Operating voltage too high (O)
HR518doc 0x0206 (518)Heating status0 = heating OK.BITMAP16Readbit 0 = Failure (F); bit 2 = Warning (W); bit 3 = Information (I)
HR521doc 0x0209 (521)Wind measurement status0 = wind measurement OK.BITMAP16Readbit 0 = Measurement volume blocked (S)
HR768doc 0x0300 (768)Wind averaging methodINT16Read/write0 = Scalar averaging; 1 = Vector averaging
HR771doc 0x0303 (771)Wind instant averaging period0.1-10 s, default 3.0.FLOAT32CDABsRead/write
HR773doc 0x0305 (773)Wind statistics period0.1-3600 s, default 600.FLOAT32CDABsRead/write
HR775doc 0x0307 (775)Invalidation delay0-20 s, default 4.0.FLOAT32CDABsRead/write
HR777doc 0x0309 (777)Wind direction offset-180 to 180, default 0.FLOAT32CDABdegRead/write
HR779doc 0x030b (779)Calm wind threshold0.2-100, default 0.2.FLOAT32CDABm/sRead/write
HR783doc 0x030f (783)Heating maximum current0-10 A, default 10.FLOAT32CDABARead/write
HR785doc 0x0311 (785)Heating temperature setpoint0-55 °C, default 45.FLOAT32CDAB°CRead/write
HR1280doc 0x0500 (1280)Heating enabledINT16Read/write0 = Disabled; 1 = Enabled
HR1536doc 0x0600 (1536)Restart deviceWrite 1 to restart.INT16Read/write
HR1538doc 0x0602 (1538)Bit rateINT16Read/write0 = 1200; 1 = 2400; 2 = 4800; 3 = 9600; 4 = 19200; 5 = 38400; 6 = 57600; 7 = 115200
HR1539doc 0x0603 (1539)Parity, data, stop bitsINT16Read/write0 = N81; 1 = N82; 2 = E81; 3 = E82; 4 = O81; 5 = O82; 6 = N71; 7 = N72; 8 = E71; 9 = E72; 10 = O71; 11 = O72
HR1541doc 0x0605 (1541)Interface modeINT16Read/write0 = Modbus; 1 = ASCII/NMEA
HR1542doc 0x0606 (1542)Modbus address1-247, default 240.INT16Read/write
HR7424doc 0x1d00 (7424)Vendor nameSTRING[16]Read
HR7432doc 0x1d08 (7432)Product codeSTRING[16]Read
HR7440doc 0x1d10 (7440)Product serial numberSTRING[16]Read
HR7680doc 0x1e00 (7680)Restore factory default settingsWrite 1 to restore.INT16Read/write
HR7936doc 0x1f00 (7936)Signed integer testAlways reads -12345.INT16Read
HR7937doc 0x1f01 (7937)Floating point testAlways reads -123.45.FLOAT32CDABRead
HR32768doc 0x8000 (32768)UptimeINT32CDABsRead
HR32770doc 0x8002 (32770)Operating voltageFLOAT32CDABVRead
HR32778doc 0x800a (32778)Heating currentFLOAT32CDABARead
HR32780doc 0x800c (32780)Transducer 1 temperatureFLOAT32CDAB°CRead
HR32782doc 0x800e (32782)Transducer 2 temperatureFLOAT32CDAB°CRead
HR32784doc 0x8010 (32784)Transducer 3 temperatureFLOAT32CDAB°CRead

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the Vaisala WM80 ultrasonic wind sensor (Modbus RTU)

What Modbus registers does the Vaisala WM80 ultrasonic wind sensor (Modbus RTU) have?

This map lists 47 registers: 47 holding registers. 15 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the Vaisala WM80 ultrasonic wind sensor (Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers hexadecimal, 0-based. Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The guide prints each register as a hex address with its decimal value (used on the wire) plus a 'register number' equal to the address + 1. Wind speed sample is at address 0x0000 (register number 1).

What byte order does the Vaisala WM80 ultrasonic wind sensor (Modbus RTU) use for 32-bit values?

Multi-register values in this map use CDAB (low word first (word-swapped)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the Vaisala WM80 ultrasonic wind sensor (Modbus RTU)?

Start with HR 4 Wind speed, instant (Instant wind speed); HR 6 Wind direction, instant (Instant wind direction); HR 8 Wind speed, average (Average wind speed); HR 14 Wind speed, gust (Gust); HR 512 Device status (Device status); HR 521 Wind measurement status (Wind measurement status).

How do I enable Modbus control of the Vaisala WM80 ultrasonic wind sensor (Modbus RTU)?

Order the sensor with the Modbus RTU communication profile (option C), or in Vaisala Insight PC software select Communication, set Interface mode to Modbus RTU, save, then power-cycle the sensor. Interface mode is also register 0x0605.

Where is the official Vaisala WM80 ultrasonic wind sensor (Modbus RTU) Modbus documentation?

The source is WM80 User Guide (M212995EN-F), revision 2025-12, published free by Vaisala at https://docs.vaisala.com/r/M212995EN-F/en-US.

More Vaisala Modbus register maps

Other valves, actuators & sensors register maps

All valves, actuators & sensors Modbus register maps →

Source: WM80 User Guide · M212995EN-F · rev. 2025-12. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.