- Fronius Sensor Card via Datamanager (SunSpec 302/303/307)
Sensor · Modbus register map
Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) Modbus register map
Updated 17 November 2026
The Datamanager publishes each Fronius Sensor Card as its own Modbus device (unit ID 245 for Solar Net address 0, up to 247). After the common block it carries SunSpec irradiance model 302, back-of-module temperature model 303 and base meteorological model 307. This map covers the identification block, irradiance, both temperature inputs and wind speed.
This page lists 20 Modbus registers for the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) — 0 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Fronius’s own free documentation (linked below) and checked against it.
- Manufacturer
- Fronius
- Model
- Fronius Sensor Card via Datamanager (SunSpec 302/303/307)
- Equipment type
- Sensor
- Registers
- 20 (0 writable)
- Transport
- Modbus TCP, Modbus RTU
- Default unit ID
- 245
- TCP port
- 502
- Documented addressing
- 1-based (subtract 1 for the wire address)
- Firmware
- Register map archive version 1.1.7-0 (IG_Sensor_Card_Register_Map_Float_and_Int&SF_v1.0.xlsx); manual 42,0410,2049 rev. 033-24022026.
- Also known as
- Fronius Sensor Card, IG Sensor Card
Integration notes: Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307)
Enable Modbus on the Datamanager and poll the sensor card at unit ID 245 + its Solar Net address. Read 40072 for irradiance and 40079-40086 for temperatures and wind speed.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| HR 40069 | Irradiance ID | UINT16 | Model ID 302 confirms the layout | Read |
| HR 40071 | GHI | UINT16 | Global horizontal irradiance | Read |
| HR 40078 | TmpBOM | INT16 | Module temperature (sensor 1) | Read |
| HR 40082 | TmpAmb | INT16 | Ambient temperature (sensor 2) | Read |
| HR 40085 | WndSpd | INT16 | Wind speed | Read |
Enable Modbus control & writes
In the Datamanager web interface open Settings > Modbus and set data output to tcp (or rtu). The sensor card must be connected to the Datamanager via Solar Net.
Byte order & addressing
- The sensor card is a separate Modbus device: unit ID = 245 + Solar Net address (0-2 -> 245-247).
- Unlike the inverter and meter models, the sensor card layout does not change between float and int+SF.
Network setup
- Sensor card Solar Net address 0 -> unit ID 245, 1 -> 246, 2 -> 247.
Watch out for
- Points marked not supported (humidity, pressure, wind direction and others) still exist in the block; ignore them.
Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| HR | 40002doc 40003 | Common ID | Common block ID, reads 1. | UINT16 | Read | ||||
| HR | 40003doc 40004 | Common L | Common block length, reads 65. | UINT16 | Read | ||||
| HR | 40004doc 40005 | Mn | Manufacturer name (Fronius). | STRING[32] | Read | ||||
| HR | 40020doc 40021 | Md | Device model name. | STRING[32] | Read | ||||
| HR | 40036doc 40037 | Opt | Options string. | STRING[16] | Read | ||||
| HR | 40044doc 40045 | Vr | Software version. | STRING[16] | Read | ||||
| HR | 40052doc 40053 | SN | Serial number. | STRING[32] | Read | ||||
| HR | 40068doc 40069 | DA | Modbus device address. | UINT16 | Read | ||||
| HR | 40069doc 40070 | Irradiance ID | SunSpec irradiance model, reads 302. | UINT16 | Read | ||||
| HR | 40070doc 40071 | Irradiance L | Model length, reads 5. | UINT16 | Read | ||||
| HR | 40071doc 40072 | GHI | Global horizontal irradiance. | UINT16 | W/m2 | Read | |||
| HR | 40076doc 40077 | BOM temperature ID | SunSpec back-of-module temperature model, reads 303. | UINT16 | Read | ||||
| HR | 40077doc 40078 | BOM temperature L | Model length, reads 2. | UINT16 | Read | ||||
| HR | 40078doc 40079 | TmpBOM | Back-of-module temperature from temperature sensor 1. | INT16 | × 0.1 | °C | Read | ||
| HR | 40080doc 40081 | Meteorological ID | SunSpec base meteorological model, reads 307. | UINT16 | Read | ||||
| HR | 40081doc 40082 | Meteorological L | Model length, reads 11. | UINT16 | Read | ||||
| HR | 40082doc 40083 | TmpAmb | Ambient temperature from temperature sensor 2. | INT16 | × 0.1 | °C | Read | ||
| HR | 40085doc 40086 | WndSpd | Wind speed. | INT16 | m/s | Read | |||
| HR | 40093doc 40094 | End ID | End block marker, reads 0xFFFF. | UINT16 | Read | ||||
| HR | 40094doc 40095 | End L | End block length, reads 0. | UINT16 | Read |
Notes on this map
- Register table from Fronius' official XLSX in the Modbus SunSpec maps ZIP; the unit-ID rule comes from the PDF.
- The XLSX gives a fixed scale factor of -1 for the temperatures (raw x 0.1); GHI and wind speed have no scale factor and are used as read.
- Left out: the 32-bit SID (40001-40002, word order not stated) and every point the XLSX marks not supported (POAI, DFI, DNI, OTI, the second TmpBOM at 40080, RH, pressure, wind direction, rain, snow, precipitation type, electric field, surface and soil wetness).
- Changelog 1.1.5-0 notes that TmpAmb (40083) is mapped to temperature sensor 2 and the second TmpBOM register is not supported.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307)
What Modbus registers does the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) have?
This map lists 20 registers: 20 holding registers. 0 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers 1-based (subtract 1 for the wire address). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. Fronius numbers registers from 1 (SunSpec base register 40001) and tells you to request the register number minus one, so register 40072 is read at wire address 40071. The manual's RTU example reads register 40005 with address bytes 9C 44 (40004).
What are the minimum Modbus registers to integrate the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307)?
Start with HR 40069 Irradiance ID (Model ID 302 confirms the layout); HR 40071 GHI (Global horizontal irradiance); HR 40078 TmpBOM (Module temperature (sensor 1)); HR 40082 TmpAmb (Ambient temperature (sensor 2)); HR 40085 WndSpd (Wind speed).
How do I enable Modbus control of the Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307)?
In the Datamanager web interface open Settings > Modbus and set data output to tcp (or rtu). The sensor card must be connected to the Datamanager via Solar Net.
Where is the official Fronius Fronius Sensor Card via Datamanager (SunSpec 302/303/307) Modbus documentation?
The source is Fronius Datamanager Modbus TCP & RTU (operating instructions) + IG_Sensor_Card_Register_Map_Float_and_Int&SF_v1.0.xlsx (42,0410,2049 (033-24022026)), revision 2026-02, published free by Fronius at https://www.fronius.com/en/~/downloads/Solar%20Energy/Operating%20Instructions/42,0410,2049.pdf.
More Fronius Modbus register maps
- Energy meter
Fronius Fronius Smart Meter via Datamanager (SunSpec meter model int+SF)
An energy meter wired to a Fronius Datamanager (or Hybridmanager) over Modbus RTU and republished by it, with SunSpec Model Type set to int+SF (meter model 201/202/203).
Also known as: Fronius Smart Meter 63A, Fronius Smart Meter 50kA, Fronius Smart Meter TS, SunSpec meter model 201/202/203 - Energy meter
Fronius Fronius Smart Meter via GEN24 / Tauro inverter (SunSpec meter model int+SF)
A Fronius Smart Meter wired to a GEN24 or Tauro inverter over Modbus RTU and republished by the inverter over Modbus TCP, with SunSpec Model Type set to int+SF (meter model 201/202/203).
Also known as: Fronius Smart Meter 63A, Fronius Smart Meter 50kA, Fronius Smart Meter TS, SunSpec meter model 201/202/203 - Solar inverter
Fronius Primo GEN24 / Symo GEN24 (Plus) SunSpec int+SF
Fronius Primo/Symo GEN24 (Plus) rest-of-world variants with a battery configured, SunSpec Model Type int+SF; without a battery the MPPT model has 2 inputs and model 124 is absent.
Also known as: Primo GEN24 Plus, Symo GEN24 Plus, Primo GEN24, Symo GEN24, Symo GEN24 10.0 Plus, Primo GEN24 6.0 Plus - Solar inverter
Fronius Primo GEN24 Plus / Symo GEN24 Plus US (SunSpec int+SF with 700-series models)
Fronius Primo/Symo GEN24 (Plus) US variants with a battery configured, SunSpec Model Type int+SF; the US map appends IEEE 1547 models 701-713 after storage model 124.
Also known as: Primo GEN24 Plus US, Symo GEN24 Plus US, Primo GEN24 10.0 208-240, Primo GEN24 3.8 208-240, Primo GEN24 6.0 208-240 - Solar inverter
Fronius Symo / Primo / Galvo / Symo Hybrid via Datamanager (SunSpec int+SF)
Fronius inverters read through a Fronius Datamanager (1.0/2.0 card or Hybridmanager) with SunSpec Model Type set to int+SF; model 124 present on Symo Hybrid.
Also known as: Fronius Symo, Fronius Primo, Fronius Galvo, Fronius Symo Hybrid, Fronius IG Plus, Datamanager 2.0 - Solar inverter
Fronius Tauro 50-3 (SunSpec int+SF)
Fronius Tauro 50-3-P / 50-3-D commercial inverters (rest-of-world map, 3 MPPT), SunSpec Model Type int+SF.
Also known as: Fronius Tauro, Tauro 50-3-P, Tauro 50-3-D - Solar inverter
Fronius Tauro ECO 50-100 (SunSpec int+SF)
Fronius Tauro ECO 50-100 kW commercial inverters (rest-of-world map, single MPPT), SunSpec Model Type int+SF.
Also known as: Fronius Tauro ECO, Tauro ECO 50-3-P, Tauro ECO 99-3-D, Tauro ECO 100-3-P, Tauro ECO 100-3-D
Other valves, actuators & sensors register maps
- Sensor (load-cell weight transmitter)
Laumas TLB4 four-channel weight transmitter (Modbus RTU / Modbus TCP)
Laumas TLB4 with the Modbus RTU port or the Modbus/TCP option; communication protocols manual version 1.12. Direct registers only.
Also known as: TLB4, TLB4 MODBUS, TLB4 Modbus/TCP - Actuator / valve
Rotork Modbus RTU Mk3 option card (IQ3, SI3/SI4, CK, CVA, CMA, K-range)
Rotork Modbus RTU Mk3 option module (MFU) in IQ3, SI3, SI4, CK, CVA (firmware CVA1.14 or later), CMA and K-range actuators, using the default Rotork database (register 80 = 0), per PUB091-004-00 issue 08/25.
Also known as: IQ3 Modbus, Rotork MFU Mk3, Modbus Mk3 module, SI3 Modbus, SI4 Modbus, CK Modbus, CVA Modbus, CMA Modbus, K-range Modbus - Sensor (room humidity / temperature)
Siemens QFA3150/MO room humidity and temperature sensor (Modbus RTU)
Siemens QFA3150/MO room relative humidity and temperature sensor, basic documentation edition a (2021-01).
Also known as: QFA3150/MO, S55720-S535 - Sensor (temperature / humidity data logger)
Teracom TCW210-TH temperature and humidity data logger
TCW210-TH per the Teracom TCW210-TH user manual Revision R1.26, firmware V2.012 or later.
Also known as: TCW210-TH, TCW210 - Sensor (humidity / temperature)
Teracom TSM400-4-TH Modbus humidity and temperature sensor
TSM400-4-TH per the Teracom TSM400-4-TH user manual TSM400-4-TH-R1.10.
Also known as: TSM400-4-TH - Sensor (CO2 duct transmitter)
Vaisala GMD110 duct CO2 transmitter (Modbus RTU)
GMD110 duct-mount CO2 transmitter, Modbus RTU interface (user guide M212885EN-B).
Also known as: GMD110, CARBOCAP GMD110
All valves, actuators & sensors Modbus register maps →
Source: Fronius Datamanager Modbus TCP & RTU (operating instructions) + IG_Sensor_Card_Register_Map_Float_and_Int&SF_v1.0.xlsx · 42,0410,2049 (033-24022026) · rev. 2026-02. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.