ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) Modbus register map

Updated 19 November 2026

Short answer

The M-7088 is an RS-485 remote I/O module with eight PWM outputs and eight digital inputs that also count pulses. Over Modbus RTU the PWM duty cycle, frequency and burst settings are holding registers, PWM start/stop and modes are coils, and the 32-bit input counts are input registers stored low word first.

This page lists 80 Modbus registers for the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) — 63 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from ICP DAS’s own free documentation (linked below) and checked against it.

Manufacturer
ICP DAS
Model
M-7088 8-channel PWM output / counter input module (Modbus RTU)
Equipment type
Sensor (PWM output and counter input module)
Registers
80 (63 writable)
Transport
Modbus RTU
Default unit ID
1
Default serial
9600 baud, 8N1
Documented addressing
Modicon 3xxxx/4xxxx (drop the prefix, subtract 1)
32-bit word order
CDAB low word first (word-swapped)
Also known as
M-7088, M7088
Source document
M-7000 Series Address Mapping Table · V1.18 · rev. 2025-09
Download CSV all columns JSON Manufacturer PDF ↗

Integration notes: ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU)

Integration in brief

Set a channel's frequency (40737+, 32-bit low word first) and duty cycle (40705+, 0.1 % steps), then start it with its PWM status coil (00001+). Read input registers 0-15 for the eight 32-bit pulse counts.

Minimum registers to map

Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.

RegisterNameTypeWhyAccess
HR 704PWM duty cycle channel 0UINT16PWM duty channel 0Read/write
HR 736PWM frequency channel 0UINT32 CDABPWM frequency channel 0Read/write
CO 0PWM status channel 0BITPWM start/stop channel 0Read/write
CO 864PWM mode channel 0BITPWM burst/continuous channel 0Read/write
IR 0DI count channel 0UINT32 CDABDI count channel 0Read
DI 32DI status channel 0BITDI status channel 0Read

Enable Modbus control & writes

The module must run the Modbus RTU protocol (coil 00257 = 1, factory default 1).

Communication loss & watchdog

Host watchdog: enable with coil 00261, timeout in 40489 (0.1 s steps, factory 25.5 s); coil 00270 shows and clears a timeout.

Byte order & addressing

Network setup

Watch out for

ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) Modbus registers

Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.

80 of 80 shown
ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) Modbus register map
TableAddressNameDescriptionTypeOrderScaleUnitsAccessValues / bits
CO0doc 00001PWM status channel 0BITRead/write0 = Stopped; 1 = Started
CO1doc 00002PWM status channel 1BITRead/write0 = Stopped; 1 = Started
CO2doc 00003PWM status channel 2BITRead/write0 = Stopped; 1 = Started
CO3doc 00004PWM status channel 3BITRead/write0 = Stopped; 1 = Started
CO4doc 00005PWM status channel 4BITRead/write0 = Stopped; 1 = Started
CO5doc 00006PWM status channel 5BITRead/write0 = Stopped; 1 = Started
CO6doc 00007PWM status channel 6BITRead/write0 = Stopped; 1 = Started
CO7doc 00008PWM status channel 7BITRead/write0 = Stopped; 1 = Started
CO64doc 00065DI counter overflow channel 0Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO65doc 00066DI counter overflow channel 1Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO66doc 00067DI counter overflow channel 2Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO67doc 00068DI counter overflow channel 3Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO68doc 00069DI counter overflow channel 4Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO69doc 00070DI counter overflow channel 5Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO70doc 00071DI counter overflow channel 6Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO71doc 00072DI counter overflow channel 7Write 1 to clear.BITRead/write0 = Normal; 1 = Overflow
CO260doc 00261Host watchdog enableBITRead/write0 = Disabled; 1 = Enabled
CO265doc 00266Clear all DI countersWrite 1.BITWrite
CO269doc 00270Host watchdog timeout statusWrite 1 to clear.BITRead/write0 = Normal; 1 = Host watchdog timeout
CO864doc 00865PWM mode channel 0BITRead/write0 = Burst; 1 = Continuous
CO865doc 00866PWM mode channel 1BITRead/write0 = Burst; 1 = Continuous
CO866doc 00867PWM mode channel 2BITRead/write0 = Burst; 1 = Continuous
CO867doc 00868PWM mode channel 3BITRead/write0 = Burst; 1 = Continuous
CO868doc 00869PWM mode channel 4BITRead/write0 = Burst; 1 = Continuous
CO869doc 00870PWM mode channel 5BITRead/write0 = Burst; 1 = Continuous
CO870doc 00871PWM mode channel 6BITRead/write0 = Burst; 1 = Continuous
CO871doc 00872PWM mode channel 7BITRead/write0 = Burst; 1 = Continuous
DI32doc 10033DI status channel 0BITRead0 = Off; 1 = On
DI33doc 10034DI status channel 1BITRead0 = Off; 1 = On
DI34doc 10035DI status channel 2BITRead0 = Off; 1 = On
DI35doc 10036DI status channel 3BITRead0 = Off; 1 = On
DI36doc 10037DI status channel 4BITRead0 = Off; 1 = On
DI37doc 10038DI status channel 5BITRead0 = Off; 1 = On
DI38doc 10039DI status channel 6BITRead0 = Off; 1 = On
DI39doc 10040DI status channel 7BITRead0 = Off; 1 = On
DI272doc 10273Reset status1 on the first read after power-on.BITRead0 = Not first read; 1 = First read after power-on
IR0doc 30001DI count channel 0Low word at the lower address.UINT32CDABRead
IR2doc 30003DI count channel 1Low word at the lower address.UINT32CDABRead
IR4doc 30005DI count channel 2Low word at the lower address.UINT32CDABRead
IR6doc 30007DI count channel 3Low word at the lower address.UINT32CDABRead
IR8doc 30009DI count channel 4Low word at the lower address.UINT32CDABRead
IR10doc 30011DI count channel 5Low word at the lower address.UINT32CDABRead
IR12doc 30013DI count channel 6Low word at the lower address.UINT32CDABRead
IR14doc 30015DI count channel 7Low word at the lower address.UINT32CDABRead
HR64doc 40065Max DI count channel 0Low word at the lower address.UINT32CDABRead/write
HR66doc 40067Max DI count channel 1Low word at the lower address.UINT32CDABRead/write
HR68doc 40069Max DI count channel 2Low word at the lower address.UINT32CDABRead/write
HR70doc 40071Max DI count channel 3Low word at the lower address.UINT32CDABRead/write
HR72doc 40073Max DI count channel 4Low word at the lower address.UINT32CDABRead/write
HR74doc 40075Max DI count channel 5Low word at the lower address.UINT32CDABRead/write
HR76doc 40077Max DI count channel 6Low word at the lower address.UINT32CDABRead/write
HR78doc 40079Max DI count channel 7Low word at the lower address.UINT32CDABRead/write
HR484doc 40485Module address1-247.UINT16Read/write
HR485doc 40486Baud rate and parityBits 0-5 baud code (03 = 1200 ... 06 = 9600 ... 0A = 115200); bits 6-7 parity/stop.UINT16Read/write
HR487doc 40488Modbus response delay0-30 ms.UINT16msRead/write
HR488doc 40489Host watchdog timeout0-25.5 s.UINT16× 0.1sRead/write
HR704doc 40705PWM duty cycle channel 00.1-99.9 %.UINT16× 0.1%Read/write
HR705doc 40706PWM duty cycle channel 10.1-99.9 %.UINT16× 0.1%Read/write
HR706doc 40707PWM duty cycle channel 20.1-99.9 %.UINT16× 0.1%Read/write
HR707doc 40708PWM duty cycle channel 30.1-99.9 %.UINT16× 0.1%Read/write
HR708doc 40709PWM duty cycle channel 40.1-99.9 %.UINT16× 0.1%Read/write
HR709doc 40710PWM duty cycle channel 50.1-99.9 %.UINT16× 0.1%Read/write
HR710doc 40711PWM duty cycle channel 60.1-99.9 %.UINT16× 0.1%Read/write
HR711doc 40712PWM duty cycle channel 70.1-99.9 %.UINT16× 0.1%Read/write
HR736doc 40737PWM frequency channel 01-500000; low word at the lower address.UINT32CDABHzRead/write
HR738doc 40739PWM frequency channel 11-500000; low word at the lower address.UINT32CDABHzRead/write
HR740doc 40741PWM frequency channel 21-500000; low word at the lower address.UINT32CDABHzRead/write
HR742doc 40743PWM frequency channel 31-500000; low word at the lower address.UINT32CDABHzRead/write
HR744doc 40745PWM frequency channel 41-500000; low word at the lower address.UINT32CDABHzRead/write
HR746doc 40747PWM frequency channel 51-500000; low word at the lower address.UINT32CDABHzRead/write
HR748doc 40749PWM frequency channel 61-500000; low word at the lower address.UINT32CDABHzRead/write
HR750doc 40751PWM frequency channel 71-500000; low word at the lower address.UINT32CDABHzRead/write
HR800doc 40801PWM burst steps channel 01-65535; used in burst mode.UINT16Read/write
HR801doc 40802PWM burst steps channel 11-65535; used in burst mode.UINT16Read/write
HR802doc 40803PWM burst steps channel 21-65535; used in burst mode.UINT16Read/write
HR803doc 40804PWM burst steps channel 31-65535; used in burst mode.UINT16Read/write
HR804doc 40805PWM burst steps channel 41-65535; used in burst mode.UINT16Read/write
HR805doc 40806PWM burst steps channel 51-65535; used in burst mode.UINT16Read/write
HR806doc 40807PWM burst steps channel 61-65535; used in burst mode.UINT16Read/write
HR807doc 40808PWM burst steps channel 71-65535; used in burst mode.UINT16Read/write

Notes on this map

Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.

Questions about the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU)

What Modbus registers does the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) have?

This map lists 80 registers: 27 coils, 9 discrete inputs, 8 input registers, 36 holding registers. 63 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.

Are the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) Modbus addresses 0-based or 1-based?

The manufacturer's document numbers registers Modicon 3xxxx/4xxxx (drop the prefix, subtract 1). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The table is titled 'M-7000 Address Mapping (Base 1)': 00001 coils, 10001 discrete inputs, 30001 input registers, 40001 holding registers. Subtract the table base for the wire address (40001 = holding register 0).

What byte order does the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) use for 32-bit values?

Multi-register values in this map use CDAB (low word first (word-swapped)). Set your client to this order for every 32/64-bit value in the table.

What are the minimum Modbus registers to integrate the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU)?

Start with HR 704 PWM duty cycle channel 0 (PWM duty channel 0); HR 736 PWM frequency channel 0 (PWM frequency channel 0); CO 0 PWM status channel 0 (PWM start/stop channel 0); CO 864 PWM mode channel 0 (PWM burst/continuous channel 0); IR 0 DI count channel 0 (DI count channel 0); DI 32 DI status channel 0 (DI status channel 0).

How do I enable Modbus control of the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU)?

The module must run the Modbus RTU protocol (coil 00257 = 1, factory default 1).

What happens when the ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) loses Modbus communication?

Host watchdog: enable with coil 00261, timeout in 40489 (0.1 s steps, factory 25.5 s); coil 00270 shows and clears a timeout.

Where is the official ICP DAS M-7088 8-channel PWM output / counter input module (Modbus RTU) Modbus documentation?

The source is M-7000 Series Address Mapping Table (V1.18), revision 2025-09, published free by ICP DAS at https://www.icpdas.com/en/download/file.php?num=19906.

More ICP DAS Modbus register maps

Other remote i/o modules register maps

All remote i/o modules Modbus register maps →

Source: M-7000 Series Address Mapping Table · V1.18 · rev. 2025-09. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.