The RGK750 is one of Lovato's RGK genset controllers. It answers Modbus RTU and ASCII on its serial ports and Modbus TCP through the EXP1013 Ethernet module, and all measurements are 32-bit values read with function 04 (or 03). This map lists the electrical measurements, engine values, hour and start counters and energy totals that the protocol document marks for this model.
This page lists 126 Modbus registers for the Lovato Electric RGK750 genset controller — 0 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Lovato Electric’s own free documentation (linked below) and checked against it.
- Manufacturer
- Lovato Electric
- Model
- RGK750 genset controller
- Equipment type
- Generator controller
- Registers
- 126 (0 writable)
- Transport
- Modbus RTU, Modbus ASCII, Modbus TCP
- Default unit ID
- Not stated
- Documented addressing
- 1-based (subtract 1 for the wire address)
- 32-bit word order
- ABCD high word first (big-endian)
- Also known as
- RGK 750
Integration notes: Lovato Electric RGK750 genset controller
Read the 32-bit measures with function 04 (or 03), two registers each, high word first, at the table address minus one. Mode bits are in the 0F98H status copy.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| IR 27 | L1-L2 Voltage - Generator | UINT32 ABCD | Generator L1-L2 voltage | Read |
| IR 91 | Frequency - Generator | UINT32 ABCD | Generator frequency | Read |
| IR 13 | L1 Current | UINT32 ABCD | Phase L1 current | Read |
| IR 111 | Eqv. Active Power - Generator | INT32 ABCD | Generator total active power | Read |
| IR 3967 | Engine working hours | UINT32 ABCD | Engine hours | Read |
| IR 4007 | Battery voltage | UINT32 ABCD | Battery voltage | Read |
| IR 3991 | Modbus Function 0x07 clone | UINT32 ABCD | Operating mode (status copy) | Read |
| IR 21 | L1-L2 Voltage - Mains (Bus) | UINT32 ABCD | Mains L1-L2 voltage | Read |
Enable Modbus control & writes
Set the communication port (built-in serial or optical port, or an EXP expansion module) in the device setup menu; see the RGK instruction manual for the menu.
Byte order & addressing
- Request one less than the printed hex address (0024H -> 0x0023).
- At most 80 registers per request.
Network setup
- Serial address, baud rate and protocol (RTU/ASCII) are set in the communication menu of the controller.
Watch out for
- Powers are in W, var and VA with two decimals, not kW.
Lovato Electric RGK750 genset controller Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| IR | 1doc 0002H | L1 Phase Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 3doc 0004H | L2 Phase Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 5doc 0006H | L3 Phase Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 7doc 0008H | L1 Phase Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 9doc 000AH | L2 Phase Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 11doc 000CH | L3 Phase Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 13doc 000EH | L1 Current | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 15doc 0010H | L2 Current | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 17doc 0012H | L3 Current | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 21doc 0016H | L1-L2 Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 23doc 0018H | L2-L3 Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 25doc 001AH | L3-L1 Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 27doc 001CH | L1-L2 Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 29doc 001EH | L2-L3 Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 31doc 0020H | L3-L1 Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 33doc 0022H | L1 Active Power - Mains (Bus) | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 35doc 0024H | L2 Active Power - Mains (Bus) | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 37doc 0026H | L3 Active Power - Mains (Bus) | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 39doc 0028H | L1 Active Power - Generator | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 41doc 002AH | L2 Active Power - Generator | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 43doc 002CH | L3 Active Power - Generator | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 45doc 002EH | L1 Reactive Power - Mains (Bus) | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 47doc 0030H | L2 Reactive Power - Mains (Bus) | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 49doc 0032H | L3 Reactive Power - Mains (Bus) | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 51doc 0034H | L1 Reactive Power - Generator | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 53doc 0036H | L2 Reactive Power - Generator | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 55doc 0038H | L3 Reactive Power - Generator | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 57doc 003AH | L1 Apparent Power - Mains (Bus) | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 59doc 003CH | L2 Apparent Power - Mains (Bus) | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 61doc 003EH | L3 Apparent Power - Mains (Bus) | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 63doc 0040H | L1 Apparent Power - Generator | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 65doc 0042H | L2 Apparent Power - Generator | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 67doc 0044H | L3 Apparent Power - Generator | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 69doc 0046H | L1 Power Factor - Mains (Bus) | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 71doc 0048H | L2 Power Factor - Mains (Bus) | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 73doc 004AH | L3 Power Factor - Mains (Bus) | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 75doc 004CH | L1 Power Factor - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 77doc 004EH | L2 Power Factor - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 79doc 0050H | L3 Power Factor - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 81doc 0052H | Eqv. Phase Voltage - Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 83doc 0054H | Eqv. Phase-To-Phase Voltage Mains (Bus) | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 85doc 0056H | Frequency - Mains (Bus) | UINT32 | ABCD | × 0.001 | Hz | Read | ||
| IR | 87doc 0058H | Eqv. Phase Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 89doc 005AH | Eqv. Phase-To-Phase Voltage - Generator | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 91doc 005CH | Frequency - Generator | UINT32 | ABCD | × 0.001 | Hz | Read | ||
| IR | 93doc 005EH | Eqv Power Factor - Mains (Bus) | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 99doc 0064H | Eqv Power Factor - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 105doc 006AH | Eqv. Active Power - Mains (Bus) | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 107doc 006CH | Eqv. Reactive Power - Mains (Bus) | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 109doc 006EH | Eqv. Apparent Power - Mains (Bus) | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 111doc 0070H | Eqv. Active Power - Generator | INT32 | ABCD | × 0.01 | W | Read | ||
| IR | 113doc 0072H | Eqv. Reactive Power - Generator | INT32 | ABCD | × 0.01 | var | Read | ||
| IR | 115doc 0074H | Eqv. Apparent Power - Generator | UINT32 | ABCD | × 0.01 | VA | Read | ||
| IR | 117doc 0076H | % Active Power - Mains (Bus) | INT32 | ABCD | × 0.01 | % | Read | ||
| IR | 119doc 0078H | % Reactive Power - Mains (Bus) | INT32 | ABCD | × 0.01 | % | Read | ||
| IR | 121doc 007AH | % Apparent Power - Mains (Bus) | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 123doc 007CH | % Active Power - Generator | INT32 | ABCD | × 0.01 | % | Read | ||
| IR | 125doc 007EH | % Reactive Power - Generator | INT32 | ABCD | × 0.01 | % | Read | ||
| IR | 127doc 0080H | % Apparent Power - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 129doc 0082H | Phase-Phase Voltage asymmetry - Mains | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 131doc 0084H | Phase-neutral Voltage asymmetry- Mains (Bus) | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 133doc 0086H | Current Asymmetry - Mains (Bus) | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 135doc 0088H | Phase-Phase Voltage asymmetry - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 137doc 008AH | Phase-neutral Voltage asymmetry - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 139doc 008CH | Current Asymmetry - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 141doc 008EH | Engine speed | UINT32 | ABCD | × 0.1 | rpm | Read | ||
| IR | 143doc 0090H | L1-2 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 145doc 0092H | L2-3 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 147doc 0094H | L3-1 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 149doc 0096H | L1 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 151doc 0098H | L2 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 153doc 009AH | L3 Voltage Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 155doc 009CH | L1 Current Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 157doc 009EH | L2 Current Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 159doc 00A0H | L3 Current Thd - Generator | UINT32 | ABCD | × 0.01 | % | Read | ||
| IR | 163doc 00A4H | L1 CosPhi - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 165doc 00A6H | L2 CosPhi - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 167doc 00A8H | L3 CosPhi - Generator | INT32 | ABCD | × 0.0001 | Read | |||
| IR | 169doc 00AAH | L1 Current - view - | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 171doc 00ACH | L2 Current - view - | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 173doc 00AEH | L3 Current - view - | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 175doc 00B0H | Neutral Current - view - | UINT32 | ABCD | × 0.0001 | A | Read | ||
| IR | 177doc 00B2H | Engine speed W or Pick-UP | UINT32 | ABCD | × 0.1 | rpm | Read | ||
| IR | 3967doc 0F80H | Engine working hours | UINT32 | ABCD | h | Read | |||
| IR | 3969doc 0F82H | Engine working time | UINT32 | ABCD | s | Read | |||
| IR | 3971doc 0F84H | Engine partial running hours | UINT32 | ABCD | h | Read | |||
| IR | 3973doc 0F86H | Engine partial running time | UINT32 | ABCD | s | Read | |||
| IR | 3975doc 0F88H | Maintenance time 1 | UINT32 | ABCD | h | Read | |||
| IR | 3977doc 0F8AH | Maintenance time 2 | UINT32 | ABCD | h | Read | |||
| IR | 3979doc 0F8CH | Maintenance time 3 | UINT32 | ABCD | h | Read | |||
| IR | 3981doc 0F8EH | Rent time | UINT32 | ABCD | h | Read | |||
| IR | 3983doc 0F90H | Good cranks | UINT32 | ABCD | Read | ||||
| IR | 3985doc 0F92H | Total cranks | UINT32 | ABCD | Read | ||||
| IR | 3987doc 0F94H | Rate good cranks | UINT32 | ABCD | × 0.1 | % | Read | ||
| IR | 3989doc 0F96H | Generator contactor closing counter | UINT32 | ABCD | Read | ||||
| IR | 3991doc 0F98H | Modbus Function 0x07 clone | Copy of the function 07 status byte; bits in notes. | UINT32 | ABCD | Read | |||
| IR | 3999doc 0FA0H | Temperature | Engine temperature in °C or °F, whichever the unit is set to. | UINT32 | ABCD | Read | |||
| IR | 4001doc 0FA2H | Pressure | UINT32 | ABCD | × 0.1 | bar | Read | ||
| IR | 4003doc 0FA4H | Fuel | UINT32 | ABCD | % | Read | |||
| IR | 4007doc 0FA8H | Battery voltage | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 4009doc 0FAAH | D+ input voltage | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 4011doc 0FACH | AC input voltage | UINT32 | ABCD | × 0.01 | V | Read | ||
| IR | 4351doc 1100H | Time remaining before switchover (GEN1-GEN2) | UINT32 | ABCD | h | Read | |||
| IR | 4353doc 1102H | Time remaining before switchover (GEN2-GEN1) | UINT32 | ABCD | h | Read | |||
| IR | 4355doc 1104H | Time remaining before switchover (GEN1-GEN2) | UINT32 | ABCD | min | Read | |||
| IR | 4357doc 1106H | Time remaining before switchover (GEN2-GEN1) | UINT32 | ABCD | min | Read | |||
| IR | 6687doc 1A20H | Total imp. Active Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6689doc 1A22H | Total exported Active Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6691doc 1A24H | Total imp. Reactive Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6693doc 1A26H | Total exp. Reactive Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6695doc 1A28H | Total Apparent Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kVAh | Read | ||
| IR | 6697doc 1A2AH | Total imp. Active Energy - Generator | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6699doc 1A2CH | Total exported Active Energy - Generator | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6701doc 1A2EH | Total imp. Reactive Energy - Generator | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6703doc 1A30H | Total exp. Reactive Energy - Generator | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6705doc 1A32H | Total Apparent Energy - Generator | UINT32 | ABCD | × 0.1 | kVAh | Read | ||
| IR | 6943doc 1B20H | Partial imp. Active Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6945doc 1B22H | Partial exported Active Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6947doc 1B24H | Partial imp. Reactive Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6949doc 1B26H | Partial exp. Reactive Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6951doc 1B28H | Partial Apparent Energy - Mains (Bus) | UINT32 | ABCD | × 0.1 | kVAh | Read | ||
| IR | 6953doc 1B2AH | Partial imp. Active Energy - Generator | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6955doc 1B2CH | Partial exported Active Energy - Generator | UINT32 | ABCD | × 0.1 | kWh | Read | ||
| IR | 6957doc 1B2EH | Partial imp. Reactive Energy - Generator | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6959doc 1B30H | Partial exp. Reactive Energy - Generator | UINT32 | ABCD | × 0.1 | kvarh | Read | ||
| IR | 6961doc 1B32H | Partial Apparent Energy - Generator | UINT32 | ABCD | × 0.1 | kVAh | Read |
Notes on this map
- Word order: the document's function 04 example decodes the reply 00 01 8D C0 as 101824, so the high word comes first (ABCD).
- Scaling follows the unit column: V/100 means hundredths of a volt (scale 0.01), A/10000 is 0.0001 A, W/100 is 0.01 W, Hz/1000 is 0.001 Hz, kWh/10 is 0.1 kWh.
- Only rows the table marks with the normal 'available' symbol for RGK750 are listed. Rows marked with the document's second symbol (no legend given) are left out.
- Register 0F98H (wire 3991) is listed as a 2-word copy of the function 07 status. Bits 0-3 are OFF/reset, MAN, AUT and TEST mode in both of the document's bit lists; bits 4, 5 and 7 differ between them (function 07 table: error, engine start request, global alarm; 0F98H list on p. 16: alarm, engine running, global output), so the register carries no bit table here.
- The 32-bit device global status at 2210H/2211H is not listed: it is printed as two 1-word rows, and for several models it carries the document's second symbol, which has no legend.
- Left out: the per-phase minimum/maximum/average blocks from 0200H upward, the 0800H and 0A00H blocks, input/output/limit/remote-variable bit words (2100H-21D0H), the per-model alarm words (2200H up), GPS data, fuel consumption (mixed l/h or gal/h units), the auxiliary sensor value and the setup parameters (tables 5-8).
- Left out: the commands table (mode change at 2F00H, key simulation at 2F0AH, remote variables at 4F00H). The address-minus-one rule is stated for reads; the document does not say whether it also applies to these write addresses.
- Rows labelled 'Mains (Bus)' are the mains-side (or bus-side) measurements, as the document names them.
- Also left out: counters CNT1-CNT8 (1D00H) and analog inputs/outputs (0F50H-0F6EH), whose units are user-set (UM1-UM8) and whose format is given only as 'long' with no sign.
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Lovato Electric RGK750 genset controller
What Modbus registers does the Lovato Electric RGK750 genset controller have?
This map lists 126 registers: 126 input registers. 0 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Lovato Electric RGK750 genset controller Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers 1-based (subtract 1 for the wire address). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The tables print hex addresses (for example 0024H) and the document says the address in the query must be one lower than the table value. Its example reads mains L2 active power, listed at 0024H, with start address 00 23. 'address' here is already reduced by one.
What byte order does the Lovato Electric RGK750 genset controller use for 32-bit values?
Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.
What are the minimum Modbus registers to integrate the Lovato Electric RGK750 genset controller?
Start with IR 27 L1-L2 Voltage - Generator (Generator L1-L2 voltage); IR 91 Frequency - Generator (Generator frequency); IR 13 L1 Current (Phase L1 current); IR 111 Eqv. Active Power - Generator (Generator total active power); IR 3967 Engine working hours (Engine hours); IR 4007 Battery voltage (Battery voltage); IR 3991 Modbus Function 0x07 clone (Operating mode (status copy)); IR 21 L1-L2 Voltage - Mains (Bus) (Mains L1-L2 voltage).
How do I enable Modbus control of the Lovato Electric RGK750 genset controller?
Set the communication port (built-in serial or optical port, or an EXP expansion module) in the device setup menu; see the RGK instruction manual for the menu.
Where is the official Lovato Electric RGK750 genset controller Modbus documentation?
The source is RGK series generating set controller - Modbus communication protocol (I375 I GB 08 22), revision 2022-08-26, published free by Lovato Electric at https://datasheet.lovatoelectric.com/DOWNLOAD/Technical/TechInstructions/32.%20CONTROLLORI%20GRUPPI%20ELETTROGENI%20E%20PROTEZIONE%20MOTORE/I375IGB08_22.pdf.
More Lovato Electric Modbus register maps
- Soft starter
Lovato Electric ADXL soft starters (Modbus RTU / ASCII / TCP)
ADXL soft starters fitted with the EXC1042 RS-485 board, per Lovato protocol addendum I454IGB03_22.
Also known as: ADXL, ADXL0030600, ADXL0045600, ADXL0060600, ADXL0075600, ADXL0085600, ADXL0115600, ADXL0135600, ADXL0162600, ADXL0195600, ADXL0250600, ADXL0320600, EXC1042 - Soft starter
Lovato Electric ADXNP soft starters with CX04 RS-485 module (Modbus RTU)
ADXNP (advanced version) soft starters fitted with the CX04 RS-485 module, per instruction manual I651 GB 02 24.
Also known as: ADXNP, CX04 - Transfer switch
Lovato Electric ATL610 automatic transfer switch controller
ATL610 ATS controller via the optical port or an EXP1010/1011/1012/1013 communication module, per protocol document I428 GB I 09 22.
Also known as: ATL610, ATL 610, EXP1012, EXP1013 - Transfer switch
Lovato Electric ATL800 / ATL900 automatic transfer switch controllers
ATL800 and ATL900 ATS controllers (document I463 GB I 11 21); LINE3, BRK3 and TB2 items are ATL900 only.
Also known as: ATL800, ATL900, ATL 800, ATL 900 - Power meter (power factor controller)
Lovato Electric DCRL3 / DCRL5 / DCRL8 power factor controllers
DCRL3, DCRL5 and DCRL8 automatic power factor controllers with optical port or EXP10xx modules (Modbus TCP on DCRL8 only), per protocol document I427 GB 05 20.
Also known as: DCRL3, DCRL5, DCRL8, DCRL 3, DCRL 5, DCRL 8 - Power meter (power analyzer)
Lovato Electric DMG7000 / DMG7500 / DMG8000 / DMG9000 power analyzers
Lovato DMG7000, DMG7500, DMG8000 and DMG9000 panel power analyzers on any Modbus port (RTU, ASCII or TCP); DMG9000-only rows are marked.
Also known as: DMG7000, DMG7500, DMG8000, DMG9000, DMG 7000, DMG 8000, DMG 9000, Lovato DMG - Pump (diesel fire pump controller)
Lovato Electric FFL700DP / FFL800DP diesel engine fire pump controllers
FFL700DP and FFL800DP diesel engine fire pump controllers (built-in RS-485, optical port, EXP1012T/EXP1013T modules on FFL800DP), per protocol document I557 GB I 11 17.
Also known as: FFL700DP, FFL800DP, FFL 700 DP, FFL 800 DP - Pump (electric fire pump controller)
Lovato Electric FFL700EP / FFL800EP electric fire pump controllers
FFL700EP and FFL800EP electric fire pump controllers (built-in RS-485, optical port, EXP1012T/EXP1013T modules on FFL800EP), per protocol document I589 GB I 08 22.
Also known as: FFL700EP, FFL800EP, FFL 700 EP, FFL 800 EP - Generator controller
Lovato Electric RGK610 genset controller
RGK610, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 610 - Generator controller
Lovato Electric RGK700 AMF genset controller
RGK700, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 700, RGK700 AMF - Generator controller
Lovato Electric RGK700SA stand-alone genset controller
RGK700SA, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 700SA, RGK700 SA - Generator controller
Lovato Electric RGK800 AMF genset controller
RGK800, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 800, RGK800 AMF - Generator controller
Lovato Electric RGK800SA stand-alone genset controller
RGK800SA, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 800SA, RGK800 SA - Generator controller
Lovato Electric RGK900 genset paralleling controller
RGK900, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 900 - Generator controller
Lovato Electric RGK900MC mains/master controller
RGK900MC, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 900MC, RGK900 MC - Generator controller
Lovato Electric RGK900SA genset paralleling controller (stand-alone)
RGK900SA, as marked in the per-model columns of the RGK series Modbus protocol document I375 I GB 08 22.
Also known as: RGK 900SA, RGK900 SA - Variable frequency drive
Lovato Electric VT1 series variable speed drives (Modbus RTU / ASCII)
Lovato VT1 series drives on the built-in RS-485 port, per communication manual I646 GB I 02 21 (Modbus part).
Also known as: VT1, Lovato VT1, VT1 series
Other generator controllers register maps
- Generator controller
SmartGen HGM6100N / HGM6100CAN Series
HGM6100N and HGM6100CAN genset controllers (HGM6110 auto-start and HGM6120 AMF variants), protocol document v1.7.
Also known as: HGM6100CAN, HGM6110N, HGM6120N, HGM6110CAN, HGM6120CAN - Generator controller (utility-tie master synchronizer)
Woodward MSLC-2 Master Synchronizer and Load Control
MSLC-2, data protocol 5200, per manual 37444G.
Also known as: MSLC2, MSLC-2 master synchronizer - Generator controller
Cummins PowerCommand 2.2 / 2.3 / 3.3 genset control (Modbus RTU)
Cummins PowerCommand 2.x and 3.x generator set controls (PC 2.2, 2.3, 3.3), per section 2 of A029X159 Issue 7; registers marked PC 3.x only are absent on PC 2.x.
Also known as: PowerCommand 2.2, PowerCommand 2.3, PowerCommand 3.3, PC2.2, PC2.3, PC3.3 - Generator controller
DEIF AGC-4 Mk II Automatic Genset Controller
AGC-4 Mk II software 6.31.0 (Modbus tables revision N), genset (GEN) application only.
Also known as: AGC-4 Mk2, AGC-4 MkII - Transfer switch
Kohler Decision-Maker MPAC 750/1200/1500 ATS controller
Kohler Decision-Maker MPAC 750, 1200 and 1500 ATS controllers, Modbus RTU on the logic board RS-485 port or Modbus TCP, per section 14 of TP-6113.
Also known as: Decision-Maker MPAC 750, Decision-Maker MPAC 1200, Decision-Maker MPAC 1500, DM MPAC - Generator controller
SmartGen HGM4010N / HGM4020N
HGM4010N (auto start) and HGM4020N (AMF) genset controllers, HGM4000N communication protocol v1.2.
Also known as: HGM4010N, HGM4000N
All generator controllers Modbus register maps →
Source: RGK series generating set controller - Modbus communication protocol · I375 I GB 08 22 · rev. 2022-08-26. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.