- Home
- Modbus register maps
- Teracom
- TCW320x-WMG 1-Wire to Modbus gateway
Sensor (1-Wire to Modbus gateway) · Modbus register map
Teracom TCW320x-WMG 1-Wire to Modbus gateway Modbus register map
Updated 19 November 2026
The TCW320x-WMG is a Teracom gateway that reads up to 20 Teracom 1-Wire sensors (or DS18B20 probes) and publishes their readings on a fixed Modbus map over RS-485 RTU and Modbus TCP. Each sensor slot holds up to two float parameters; the map also has the serial settings, word-order switch and identity strings.
This page lists 52 Modbus registers for the Teracom TCW320x-WMG 1-Wire to Modbus gateway — 4 writable — with the table, 0-based wire address, data type, word order, scale, units and access of each, re-typed from Teracom’s own free documentation (linked below) and checked against it.
- Manufacturer
- Teracom
- Model
- TCW320x-WMG 1-Wire to Modbus gateway
- Equipment type
- Sensor (1-Wire to Modbus gateway)
- Registers
- 52 (4 writable)
- Transport
- Modbus RTU, Modbus TCP
- Default unit ID
- 1
- Default serial
- 19200 baud, 8E1
- TCP port
- 502
- Documented addressing
- 0-based (the number printed is the address on the wire)
- 32-bit word order
- ABCD high word first (big-endian)
- Also known as
- TCW320E-WMG, TCW320W-WMG
Integration notes: Teracom TCW320x-WMG 1-Wire to Modbus gateway
Read the sensor parameters as floats from PDU 1010 onward with function 03, over RS-485 or Modbus TCP. Lock sensor positions in the web interface so slots do not move.
Minimum registers to map
Addresses are 0-based wire addresses. Enough to monitor and run the unit; map more as the job needs.
| Register | Name | Type | Why | Access |
|---|---|---|---|---|
| HR 1010 | Sensor 1 Parameter 1 | FLOAT32 ABCD | Sensor 1 parameter 1 | Read |
| HR 1012 | Sensor 1 Parameter 2 | FLOAT32 ABCD | Sensor 1 parameter 2 | Read |
| HR 1020 | Sensor 2 Parameter 1 | FLOAT32 ABCD | Sensor 2 parameter 1 | Read |
| HR 13 | Data order | UINT16 | Word order | Read/write |
| HR 14 | Device code | UINT16 | Device code check | Read |
Enable Modbus control & writes
Modbus TCP is enabled or disabled on the Modbus page of the web interface (default port 502); the RTU slave address, baud and parity are set there too and apply after saving.
Byte order & addressing
- Word order of every float is set by PDU 13.
- The web Modbus page shows data bits and stop bits but does not let you change them (factory default 8 data, 1 stop).
- Baud rate and framing written to PDU 11-12 only take effect after a power cycle.
Network setup
- Factory network defaults: Ethernet variant 192.168.1.2; Wi-Fi variant in AP mode at 192.168.4.1.
- Set RTU address/baud/parity on the Modbus page and save.
Watch out for
- A missing or failed sensor reads NaN.
Teracom TCW320x-WMG 1-Wire to Modbus gateway Modbus registers
Address = 0-based wire address (the documented number is shown under it when it differs) · Order: ABCD = high word first, CDAB = low word first · Scale: engineering value = raw × scale.
| Table | Address | Name | Description | Type | Order | Scale | Units | Access | Values / bits |
|---|---|---|---|---|---|---|---|---|---|
| HR | 10 | RS-485 address | Modbus RTU slave address. | UINT16 | Read/write | ||||
| HR | 11 | Baud rate | Serial baud rate; applied after a power cycle. | UINT16 | Read/write | ||||
| HR | 12 | Parity, data, stop bits | Serial framing; applied after a power cycle. | UINT16 | Read/write | 1 = 8 data bits, even parity, 1 stop (E81); 2 = 8 data bits, odd parity, 1 stop (O81); 3 = 8 data bits, no parity, 1 stop (N81) | |||
| HR | 13 | Data order | Word order for all 32-bit values. | UINT16 | Read/write | 1 = MSWF - most significant word first; 2 = LSWF - least significant word first | |||
| HR | 14 | Device code | Fixed product code. | UINT16 | Read | ||||
| HR | 15 | FW version | Firmware version number. | UINT16 | Read | ||||
| HR | 18 | Vendor URL | Maker URL as UTF-8 text. | STRING[64] | Read | ||||
| HR | 86 | Signed integer test value | INT16 | Read | |||||
| HR | 91 | Unsigned integer test value | UINT16 | Read | |||||
| HR | 100 | System Name | Device text field, UTF-8. | STRING[32] | Read | ||||
| HR | 200 | System Location | Device text field, UTF-8. | STRING[32] | Read | ||||
| HR | 300 | System Contact | Device text field, UTF-8. | STRING[32] | Read | ||||
| HR | 1010 | Sensor 1 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1012 | Sensor 1 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1020 | Sensor 2 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1022 | Sensor 2 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1030 | Sensor 3 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1032 | Sensor 3 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1040 | Sensor 4 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1042 | Sensor 4 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1050 | Sensor 5 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1052 | Sensor 5 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1060 | Sensor 6 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1062 | Sensor 6 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1070 | Sensor 7 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1072 | Sensor 7 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1080 | Sensor 8 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1082 | Sensor 8 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1090 | Sensor 9 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1092 | Sensor 9 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1100 | Sensor 10 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1102 | Sensor 10 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1110 | Sensor 11 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1112 | Sensor 11 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1120 | Sensor 12 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1122 | Sensor 12 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1130 | Sensor 13 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1132 | Sensor 13 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1140 | Sensor 14 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1142 | Sensor 14 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1150 | Sensor 15 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1152 | Sensor 15 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1160 | Sensor 16 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1162 | Sensor 16 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1170 | Sensor 17 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1172 | Sensor 17 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1180 | Sensor 18 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1182 | Sensor 18 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1190 | Sensor 19 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1192 | Sensor 19 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1200 | Sensor 20 Parameter 1 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read | |||
| HR | 1202 | Sensor 20 Parameter 2 | Measurement from the 1-Wire sensor in this slot; NaN if unavailable. | FLOAT32 | ABCD | Read |
Notes on this map
- 32-bit values follow the Data order register (PDU 13): 1 = most significant word first (default), 2 = least significant word first. The map shows the default, ABCD.
- Sensor slot n uses PDU 1000 + 10n for parameter 1 and +2 for parameter 2; the unit depends on the sensor type found in that slot.
- Left out: the 32-bit float/integer test-value registers (PDU 82-95).
Check it against the live device. A register map tells you what the controller can expose; the unit in front of you may differ by firmware or options. Read a few registers and compare them with the unit’s own display; for a 32-bit value the float and byte-order decoder shows all four word orders at once, so a wrong word order or scale is obvious. New to this? Read what a register map is and why addresses are off by one.
Questions about the Teracom TCW320x-WMG 1-Wire to Modbus gateway
What Modbus registers does the Teracom TCW320x-WMG 1-Wire to Modbus gateway have?
This map lists 52 registers: 52 holding registers. 4 of them can be written. Registers vary with firmware, options and configuration, so confirm against the device.
Are the Teracom TCW320x-WMG 1-Wire to Modbus gateway Modbus addresses 0-based or 1-based?
The manufacturer's document numbers registers 0-based (the number printed is the address on the wire). Every address on this page is the 0-based wire address you put in the request; the documented number is shown under it where it differs. The manual prints PDU (zero-based) addresses only and says so in its addressing section; send them as printed.
What byte order does the Teracom TCW320x-WMG 1-Wire to Modbus gateway use for 32-bit values?
Multi-register values in this map use ABCD (high word first (big-endian)). Set your client to this order for every 32/64-bit value in the table.
What are the minimum Modbus registers to integrate the Teracom TCW320x-WMG 1-Wire to Modbus gateway?
Start with HR 1010 Sensor 1 Parameter 1 (Sensor 1 parameter 1); HR 1012 Sensor 1 Parameter 2 (Sensor 1 parameter 2); HR 1020 Sensor 2 Parameter 1 (Sensor 2 parameter 1); HR 13 Data order (Word order); HR 14 Device code (Device code check).
How do I enable Modbus control of the Teracom TCW320x-WMG 1-Wire to Modbus gateway?
Modbus TCP is enabled or disabled on the Modbus page of the web interface (default port 502); the RTU slave address, baud and parity are set there too and apply after saving.
Where is the official Teracom TCW320x-WMG 1-Wire to Modbus gateway Modbus documentation?
The source is TCW320E-WMG / TCW320W-WMG User Manual (Revision R1.0), revision 2026-10, published free by Teracom at https://www.teracomsystems.com/download/tcw320x-wmg-1-wire-to-modbus-gateway-user-manual/.
More Teracom Modbus register maps
- Sensor (temperature / humidity data logger)
Teracom TCW210-TH temperature and humidity data logger
TCW210-TH per the Teracom TCW210-TH user manual Revision R1.26, firmware V2.012 or later.
Also known as: TCW210-TH, TCW210 - Sensor (Ethernet data logger / I/O module)
Teracom TCW220 Ethernet data logger
TCW220 per the Teracom TCW220 user manual Revision R4.24, firmware V2.012 or later.
Also known as: TCW220 - Sensor (Ethernet I/O module)
Teracom TCW241 Ethernet I/O module
TCW241 per the Teracom TCW241 user manual Revision R4.30, firmware v2.012 or later.
Also known as: TCW241 - Energy meter (Ethernet energy monitoring / data logger)
Teracom TCW260 Ethernet energy monitoring module
TCW260 per the Teracom TCW260 user manual Revision R1.19, firmware V3.009 or later.
Also known as: TCW260 - Sensor (Ethernet analog / digital output module)
Teracom TCW280 Ethernet analog output module
TCW280 per the Teracom TCW280 user manual TCW280_R1.8.
Also known as: TCW280 - Energy meter (S0 pulse counter / digital input module)
Teracom TDI340 4-channel S0 pulse counter with Modbus RTU
TDI340 per the Teracom TDI340 user manual Revision R1.11, firmware V1.06 or later.
Also known as: TDI340 - Sensor (relay output module)
Teracom TDO340 4-channel Modbus RTU relay output module
TDO340 per the Teracom TDO340 user manual Revision R1.2, firmware V1.03 or later.
Also known as: TDO340 - Sensor (water leak detector)
Teracom TSF400-4 water-leak detector with Modbus RTU
TSF400-4 per the Teracom TSF400-4 user manual Revision R1.2.
Also known as: TSF400-4 - Sensor (humidity / temperature)
Teracom TSH300v3 RS-485 humidity and temperature sensor
TSH300v3 per the Teracom TSH300v3 user manual Revision R1.17.
Also known as: TSH300, TSH300v3 - Sensor (humidity / temperature)
Teracom TSH331 IP54 Modbus RTU humidity and temperature sensor
TSH331 per the Teracom TSH331 user manual Rev. 1.5, firmware v1.08 or later.
Also known as: TSH331 - Sensor (CO2 / pressure)
Teracom TSM400-4-CP Modbus CO2 and barometric pressure sensor
TSM400-4-CP per the Teracom TSM400-4-CP user manual TSM400-4-CP-R1.9.
Also known as: TSM400-4-CP - Sensor (CO2 / humidity / temperature / pressure)
Teracom TSM400-4-CPTH Modbus CO2, humidity, temperature and pressure multi-sensor
TSM400-4-CPTH per the Teracom TSM400-4-CPTH user manual TSM400-4-CPTH-R1.9.
Also known as: TSM400-4-CPTH - Sensor (humidity / temperature)
Teracom TSM400-4-TH Modbus humidity and temperature sensor
TSM400-4-TH per the Teracom TSM400-4-TH user manual TSM400-4-TH-R1.10.
Also known as: TSM400-4-TH - Sensor (temperature)
Teracom TST300v3 / TST300v4 RS-485 precision temperature sensor
TST300v3/v4 per the Teracom TST300v3/v4 user manual Revision R1.19.
Also known as: TST300, TST300v3, TST300v4 - Sensor (thermocouple input module)
Teracom TST320 2-channel thermocouple module with Modbus RTU
TST320 per the Teracom TST320 user manual Revision R1.6.
Also known as: TST320 - Sensor (AC/DC voltage transducer)
Teracom TSV300 AC/DC voltage transducer with Modbus RTU
TSV300 per the Teracom TSV300 user manual Revision R1.4, firmware V1.06 or later.
Also known as: TSV300
Other ac & vrf gateways register maps
- VRF / split AC gateway (IR-to-Modbus controller)
Cuby Cuby smart AC controller (Modbus RTU)
Cuby smart IR controllers for mini-split air conditioners with the Modbus RTU firmware described in the 2025 'MODBUS REGISTERS' sheet (fixed address 1).
Also known as: Cuby Smart, Cuby AC controller, Cuby minisplit controller - VRF / split AC gateway
Gree Modbus Gateway (Mini) ME30-24/E6(M) for GMV multi VRF systems
Gree Modbus Gateway (Mini) on CAN-bus multi VRF systems (GMV5, GMV5 C/E/HR/MAX/MINI/SLIM, GMV Water, energy-recovery ventilation); Communication Protocol V2.0, multi VRF part only.
Also known as: ME30-24/E6(M), Modbus Gateway(Mini), GMV5 Modbus gateway - VRF / split AC gateway
Intesis (HMS Networks) IN770AIR***O000 700 Series Air Gateway, Mitsubishi Electric City Multi application (Modbus)
Intesis 700 Series Air Gateway IN770AIR***O000 with the Mitsubishi Electric City Multi application (M-NET centralised controllers (AE-200, EW-50, G-50 and others)), Modbus RTU / TCP server, user manual version 1.0.19 (2026-03-16).
Also known as: IN770AIR00MO000, IN770AIR00SO000, IN770AIRXXSO000 - VRF / split AC gateway
Intesis (HMS Networks) INMBSFGL001I000 Fujitsu domestic AC to Modbus RTU gateway
One Fujitsu domestic (RAC) or compatible VRF indoor unit, connected to the CN65/CN12/CN6 socket on the indoor board via INMBSFGL001I000, user manual v1.5 (01/2024).
Also known as: INMBSFGL001I000, FJ-AC-MBS-1, Intesis Fujitsu domestic Modbus - VRF / split AC gateway
Intesis (HMS Networks) INMBSLGE001R000 LG AC to Modbus RTU gateway
One LG indoor unit on the BYR (wired remote) bus via INMBSLGE001R000 (legacy code LG-RC-MBS-1), user manual v1.9 (01/2024).
Also known as: INMBSLGE001R000, LG-RC-MBS-1, Intesis LG Modbus - VRF / split AC gateway
Intesis (HMS Networks) INMBSMIT050C000 / INMBSMIT100C000 Mitsubishi Electric City Multi centralised controller to Modbus gateway
Intesis Modbus Server - Mitsubishi Electric CC, order codes INMBSMIT050C000 / INMBSMIT100C000 (legacy ME-AC-MBS-50 / -100), user manual r1.4 (05/2021); talks to City Multi centralised controllers (G-50A, GB-50A, AG-150A, EB-50, EW-50, AE-200 and newer) through their XML interface over Ethernet.
Also known as: INMBSMIT050C000, INMBSMIT100C000, ME-AC-MBS-50, ME-AC-MBS-100, Intesis Modbus Server Mitsubishi Electric CC
All ac & vrf gateways Modbus register maps →
Source: TCW320E-WMG / TCW320W-WMG User Manual · Revision R1.0 · rev. 2026-10. Register numbers, types, scaling and units are reproduced as published; descriptions are our own.